48V 480W industrial DIN rail power supply with load sharing and adjustable output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | Industrial, DIN Rail Power Supplies |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 48V 480W |
| Key electrical range | AC Voltage - Input: 340 ~ 575 VAC (3 Phase); Current - Output (Max): 10A; Input Type: AC; Number of Outputs: 1 |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The DPP480-48-3 carries conflicting lifecycle signals. While its general status is Active, the manufacturer has explicitly marked it as Not For New Designs (NRND). This means TDK-Lambda does not recommend this part for new projects and may limit future support. For sustaining production, the part remains orderable, but procurement teams should anticipate eventual obsolescence.
Engineers should evaluate next-generation alternatives such as the DPP series upgrade for new designs. Verify directly with TDK-Lambda regarding last-time buy notices and end-of-life timelines. File-provided inventory shows limited stock (13 units), which is not a real-time guarantee. Consider qualifying an alternative supply chain path early.
In summary, treat DPP480-48-3 as NRND, and initiate migration planning now to avoid production disruptions.
Parameter Analysis
Key parameters include 480W output power, 48V output voltage, 10A maximum current, and 3-phase AC input range of 340-575 VAC. With 91% efficiency, thermal management is manageable, but the operating temperature of -40°C to 71°C requires derating at extremes—plan for adequate cooling in enclosures. Input voltage range suits industrial mains voltages worldwide.
The 3 kV isolation provides safety margin for ITE applications. The unit offers adjustable output and load sharing, enabling parallel operation for redundancy or higher power. Physical dimensions (118.9mm x 150.1mm x 124.0mm) fit standard DIN rail constraints.
Missing specifications include hold-up time, ripple and noise, protection features (overvoltage, overcurrent), and MTBF. Verify these from the official datasheet before finalizing design integration.
Application Scenario Analysis
This supply is targeted at industrial automation, machinery control panels, and commercial ITE equipment requiring 48V DC power from 3-phase mains. Strong-fit scenarios include factory-floor equipment with DIN rail mounting, where load sharing supports scalable 48V distribution. It is well-suited for process control systems, motor drives, and sensor networks in heavy industrial environments.
Weak-fit scenarios include single-phase installations (since input is 3-phase only) or tight enclosures with limited airflow; the derating curve must be carefully followed. Also, for designs needing compliance beyond CE (such as UL/CSA), additional certifications are not listed and must be confirmed.
Not recommended for consumer or residential use due to industrial input range and mounting style. Verify fit with application-specific certifications before procurement.
RoHS Certification Analysis
The DPP480-48-3 is listed as RoHS Compliant, indicating compliance with EU Directive 2011/65/EU and its amendment (EU) 2015/863 restricting hazardous substances. This status covers the product family as declared by TDK-Lambda.
However, compliance may be lot-dependent, and procurement should request certificates of conformity per shipment. Exemptions, if any (e.g., lead in high-melting-temperature solders), are not specified in the provided data and must be verified directly. For full regulatory assurance, also check REACH compliance and conflict minerals reporting.
The product is CE marked, but that alone does not confirm RoHS; always obtain manufacturer statements. Treat the RoHS status as provisional until validated with current documentation.
Availability & Sourcing
Sourcing the DPP480-48-3 requires attention due to its NRND status and limited file-provided inventory (13 units). As a Not For New Designs part, buyers should request a quote for available stock and confirm lead times promptly. Given the shortage indication, competitive sourcing is advisable.
Verify package condition (bulk) and request date/lot code for traceability. Ensure that lifecycle verification with TDK-Lambda is included in the quote process. For ongoing production, negotiate last-time buy quantities and buffer inventory.
This part’s 3-phase input and industrial form factor may limit alternative pin-compatible substitutes, so early qualification of a replacement from the manufacturer’s active portfolio is critical. Contact an authorized distributor to discuss migration options and secure long-term supply.
View the Win-Source product page for DPP480-48-3.
Engineering Notes for BOM and GEO Use
- The DPP480-48-3 is Not For New Designs; verify last-time buy options and plan alternate sourcing for future production.
- Confirm input voltage compatibility—340-575 VAC 3-phase—and derating at temperature extremes.
- Request full RoHS and REACH compliance certificates for each lot to ensure regulatory conformity.