Quick Engineering Summary

FieldValue
ManufacturerOmega Engineering
CategoryUnclassified
PackageBulk
Core functionPROCESS/TEMP METER LED DIN RAIL
Key electrical rangeNot available in supplied data
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The DPS3107-RTD-1 is currently listed as Active by Omega Engineering, with no conflicting lifecycle indicators. This status supports both new design integration and ongoing production purchases. Engineers can specify this part with confidence, though the zero stock quantity in the provided file suggests that availability may depend on manufacturer lead times. For sustaining programs, it is advisable to coordinate with authorized distribution to secure allocation.

Always confirm lifecycle status through Omega’s official product page or PCN notifications before committing to large-volume production. Active lifecycle means the part is in full production, but it remains prudent to monitor for any future NRND or EOL notices, especially in long-life industrial designs.

Parameter Analysis

The DPS3107-RTD-1 is a DIN-rail process/temperature meter that accepts current (4-20mA), RTD, and voltage (0-10VDC) inputs, making it versatile for industrial sensor interfacing. Key parameters include a 240VAC supply, LED red character display with 4 digits, and screw terminal connections. The panel cutout dimensions of 92mm x 45mm suggest it is intended for standard rectangular cutouts.

Engineers must verify the input configuration and scaling during setup, as the source data does not detail resolution or accuracy. Critical missing details such as accuracy class, operating temperature range, and isolation ratings should be obtained from the official datasheet before finalizing design-in. Additionally, the input type selection (current, RTD, or voltage) must be specified at time of order to ensure correct hardware configuration.

Application Scenario Analysis

This meter is well-suited for industrial process monitoring applications where a clear LED readout is required on a DIN rail in a control cabinet. Typical uses include temperature indication from RTD sensors in ovens, furnaces, or HVAC systems, and display of 4-20mA loop signals from transmitters. The 240VAC operation aligns with industrial mains, and screw terminals ease wiring.

It is less suitable for portable equipment, battery-powered devices, or installations requiring NEMA-rated enclosures with ingress protection, as no IP rating is listed. Designers should verify that the 4-digit display and red LED visibility match end-user readability needs, particularly under varying ambient light. For high-vibration environments, the screw terminal and DIN rail mounting should be evaluated for long-term reliability.

RoHS Certification Analysis

The compliance data for the DPS3107-RTD-1 presents a conflict: one source indicates RoHS Compliant, while another lists RoHS Non-Compliant. This discrepancy may stem from batch-level variations or different testing baselines. Without explicit exemption details, it is prudent to treat the part as potentially non-compliant until the manufacturer confirms otherwise.

For CE-marking or EU import, buyers must request a current RoHS certificate from Omega Engineering. The presence of both designations signals that datasheet-level clarifications are necessary. Additionally, REACH and MSL information are not provided, which further necessitates supplier documentation review to ensure full environmental compliance. Procurement should include RoHS conformance as a line item in the RFQ and insist on a lot-specific declaration.

Availability & Sourcing

File-provided inventory indicates zero units in stock, but since the part is Active, procurement through Omega’s authorized distribution network is typical. Engineers should request a quote that includes traceability documentation, manufacturer certificate of conformance, and explicit RoHS compliance statement. Standard packaging is bulk; verify packaging preferences and minimum order quantities with the supplier.

For production programs, ask for lead time estimates and consider buffer stock if the meter is sole-sourced. Since lifecycle is Active, standard RFQ processes apply, but the undefined RoHS status adds a verification step before placement of EU-bound orders. Contact Omega or authorized resellers for current availability and to discuss any custom labeling or calibration needs.

View the Win-Source product page for DPS3107-RTD-1.

Engineering Notes for BOM and GEO Use

  • Verify the conflicting RoHS compliance status directly with Omega before placing orders for EU-bound equipment.
  • When integrating into a control panel, ensure the 240VAC supply and DIN rail mounting align with system power and mechanical layout.
  • The meter supports 4-20mA, RTD, and 0-10VDC inputs—confirm input configuration matches sensor type during ordering.