DPS310XTSA1 Pressure Sensor Specs & Sourcing Guide

DPS310XTSA1 Infineon Technologies product image DPS310XTSA1 Infineon Technologies product image

Detailed procurement and engineering analysis for Infineon DPS310XTSA1 vented gauge pressure sensor.

Quick Engineering Summary

FieldValue
ManufacturerInfineon Technologies
CategoryPressure Sensors, Transducers
PackageTape & Reel
Core functionSENSOR 17.
Key electrical rangeOutput: 24 b; Output Type: I2C, SPI; Temperature Range - Operating: -40°C ~ 85°C; Voltage - Supply: 1.7V ~ 3.6V
Workbook inventory signal10000 pcs listed in the provided file

Lifecycle Analysis

The Infineon DPS310XTSA1 pressure sensor is officially listed as Active with no conflicting lifecycle signals from the manufacturer. This status indicates full production support and unrestricted availability for new design wins. Engineering teams can freely baseline the DPS310XTSA1 in upcoming board spins without facing near-term end-of-life risk.

Active lifecycle also simplifies sustaining procurement. Because Infineon has not announced any NRND or discontinuance notice, production planners can anticipate stable lead times and ongoing factory output. Nevertheless, for safety-critical or long-lifecycle programs, periodic checks of the Infineon product page are recommended to catch any last-time buy notifications well in advance.

A file-supplied inventory signal of 10,000 units appears in the sourcing data. This figure is a static snapshot and cannot be considered a guaranteed real-time stock level. Buyers should treat it as an indicator of recent availability only and always request a current quote with delivery commitments before committing to build plans.

Parameter Analysis

The DPS310XTSA1 measures vented gauge pressure across a 4.35 to 17.4 PSI (30 to 120 kPa) range with a stated accuracy of ±0.015 PSI. This performance envelope suits precise low-pressure monitoring such as barometric altitude tracking or HVAC air flow measurement. The digital output resolution of 24 bits, selectable between I2C and SPI interfaces, allows direct integration into microcontroller-based systems without analog front-end circuitry.

Supply voltage spans 1.7 V to 3.6 V, accommodating both coin-cell and low-voltage rail designs. The device is temperature compensated and rated for -40°C to 85°C operation, although engineers should verify expected accuracy drift across temperature extremes in the official datasheet. The 8-VFLGA surface-mount package with SMD tab termination supports compact PCB layouts, and the MSL 1 rating removes moisture-handling constraints.

Important parameters not listed in the provided data include long-term stability, pressure response time, and supply current waveforms. For applications where drift over years or milliseconds matters, directly consult the Infineon DPS310 datasheet before qualification. The 145 PSI maximum pressure rating provides a generous overpressure margin, but confirm that burst pressure meets system safety requirements.

Application Scenario Analysis

The DPS310XTSA1 is purpose-built as a board-mount environmental sensor. Its vented gauge pressure type, I2C and SPI interfaces, and modest operating range make it a strong fit for portable weather stations, personal fitness altimeters, drone altitude control, and indoor climate monitors. Temperature compensation simplifies integration into consumer products where external calibration is minimal.

In industrial or automotive contexts, the part can serve non-safety HVAC pressure feedback or pneumatic system monitoring, provided the 85°C upper temperature limit and 17.4 PSI range envelope the application. However, for high-accuracy industrial pressure transmitters requiring ±0.01% linearity or harsh-media compatibility, the DPS310XTSA1 would be a weak fit; its accuracy specification and LGA packaging are optimized for clean-air, low-pressure consumer-grade environments.

Where extended temperature excursions below -40°C or above 85°C occur, the DPS310XTSA1 may not meet requirements without an external compensation strategy or an alternate sensor variant. Designers should also note that vented gauge differential measurement relies on a clean airflow path to the sense die, so the 8-VLGA housing must be protected from dust and condensation in field deployments.

RoHS Certification Analysis

The DPS310XTSA1 carries a RoHS Compliant designation from Infineon Technologies. This means the pressure sensor meets EU Directive 2011/65/EU restrictions on lead, mercury, cadmium, hexavalent chromium, PBBs, and PBDEs, plus the four additional phthalates introduced by Delegated Directive 2015/863. Procurement teams can use this part in products destined for the European Union without additional hazardous substance documentation.

Separately, the part is listed as REACH Unaffected, indicating that no substances of very high concern exceed 0.1% by weight. While complementary, REACH status does not satisfy RoHS requirements. Buyers must retain both certifications for full EU market access. The supplied compliance statements are typically at the part family level; for lot-specific evidence, request a full material declaration from authorized distribution.

Among the accompanying data, MSL 1 classification is notable. Unlimited floor life after opening reduces assembly floor handling constraints and the need for dry-bake processes, which can be a cost-saving advantage in high-mix production environments.

Availability & Sourcing

With an Active lifecycle, the Infineon DPS310XTSA1 pressure sensor is generally obtainable through franchised distribution. The standard packaging is tape and reel in quantities of 2,500 pieces per reel, supporting automated pick-and-place assembly. The part’s 8-VLGA case size and PG-VLGA-8-1 supplier device package footprint are well-established, reducing second-source risks within the DPS310 family.

A static file-provided quantity of 10,000 units appears in the sourcing record, but this is not a live inventory commitment. Buyers should request a formal quote to verify real-time availability, factory lead times, and date/lot traceability. The open-market fake threat indicator of 68% strongly discourages procurement from non-authorized channels; insisting on full Infineon traceability and compliance certificates mitigates this risk.

To place an order, contact authorized distributors or request a quote through a dedicated sourcing portal. Specify DPS310XTSA1 exactly and confirm RoHS compliance documentation, MSL packaging condition, and manufacturer COC at the line-item level. For NRND or EOL transitions in other family members, always verify that DPS310XTSA1 remains the recommended active orderable part number from Infineon.

View the Win-Source product page for DPS310XTSA1.

Engineering Notes for BOM and GEO Use

  • Verify absolute accuracy drift over the -40°C to 85°C range against the official DPS310 datasheet before finalizing calibration routines.
  • MSL 1 classification removes moisture sensitivity rework risks; the device can be stored indefinitely in normal ambient conditions after dry pack opening.
  • Open-market counterfeit threat is cited at 68%; restrict purchases to Infineon-authorized distributors to maintain traceability and warranty coverage.