Dual-Band 2.4/5GHz SMD Diplexer in 0603 Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | RF Multiplexers |
| Package | Tape & Reel (TR);Cut Tape (CT) |
| Core function | DIPLEXER 2. |
| Key electrical range | Frequency Bands (Low / High): 2.4GHz ~ 2.5GHz / 5.15GHz ~ 5.875GHz |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
Manufacturer Pulse lists the DPX1608LKEFR2455L as Active, with no lifecycle conflicts across the supplied product-status signals. Active status indicates the part is in full production and recommended for new designs as well as ongoing volume manufacturing. Engineers can expect long-term availability and manufacturer support, making this diplexer suitable for programs requiring a stable, production-proven front-end component.
Nonetheless, lifecycle classifications may change without immediate notice. For high-volume or long-lifecycle programs, it is prudent to revalidate status directly with Pulse or authorized distributors, especially if a design freeze is planned far in advance. The workbook shows a file-provided quantity of one unit, which is not a guarantee of real-time inventory but suggests that procurement teams should request current availability and lead times. Active lifecycle typically simplifies sourcing, but dual-sourcing or alternate qualification may be considered for risk mitigation in critical applications.
Parameter Analysis
The DPX1608LKEFR2455L is characterized by two defined frequency bands: low band 2.4 GHz to 2.5 GHz and high band 5.15 GHz to 5.875 GHz, covering the primary WLAN 2.4 GHz and 5 GHz ISM bands. Attenuation specifications differentiate the performance: low-band attenuation ranges from 30.00 dB minimum to 34.90 dB maximum, while high-band attenuation is tighter, from 40.00 dB minimum to 44.10 dB maximum. These values indicate the isolation the diplexer provides between the two RF paths; higher attenuation minimizes cross-band interference, which is critical for maintaining signal integrity in dual-band transceivers.
Return loss is specified at 13.0 dB for both low and high bands, which corresponds to a VSWR of approximately 1.6:1. This should be considered in the RF link budget, as mismatch losses can degrade overall system performance. The surface-mount 0603 package (1.6 mm × 0.8 mm) enables compact layout designs. Missing from the supplied data are insertion loss, power-handling capability, and characteristic impedance (typically 50 Ω), which are necessary for accurate system-level simulation. Engineers should obtain the full datasheet to verify these parameters, as well as thermal derating curves if the design operates at elevated temperatures or high power.
Application Scenario Analysis
This diplexer is optimized for separating 2.4 GHz and 5 GHz signals in dual-band wireless communication systems, such as Wi-Fi 6/6E access points, routers, and client modules. Its compact 0603 footprint suits space-constrained PCB designs like IoT gateways, mesh nodes, and embedded wireless modules where board real estate is at a premium. The device is also applicable in test instrumentation or multi-band antennas requiring low-loss frequency splitting.
Applications that demand wider frequency coverage beyond the specified bands, such as sub-1 GHz or 6 GHz operation, would not be well served by this part. Similarly, high-power transmitters exceeding the unspecified power rating could risk damage or degraded linearity; for example, outdoor point-to-point backhaul radios often require higher power handling. When integrating this diplexer, designers should follow Pulse’s recommended PCB layout and impedance-matching guidelines to achieve the specified attenuation and return loss. Without detailed S-parameter models, it is advisable to prototype and characterize early in development to confirm in-situ performance.
RoHS Certification Analysis
The DPX1608LKEFR2455L is marked as RoHS Compliant, which indicates conformance to the European Union’s Directive on the restriction of hazardous substances. This typically covers substances such as lead, mercury, cadmium, and others. No specific standard version (e.g., RoHS 3 with 2015/863) is stated in the provided data, but most active components are expected to meet current requirements. Compliance is likely assessed at the component family level, but for rigorous procurement, lot-specific certification or test reports may be requested from Pulse.
REACH status is not explicitly listed; however, RoHS compliance does not automatically guarantee REACH conformance, as REACH addresses a broader range of chemicals. Engineers needing full material declarations for CE marking or internal environmental policies should verify with the manufacturer. Similarly, moisture sensitivity level (MSL) and peak reflow temperature are not provided, which are important for surface-mount assembly. As a passive RF component, the diplexer is unlikely to contain SVHC beyond typical ceramic and metal elements, but confirmation is recommended for export-controlled products.
Availability & Sourcing
Sourcing the DPX1608LKEFR2455L benefits from its Active lifecycle status, which generally means shorter lead times and availability through franchised distributors. The workbook indicates a file-provided quantity of one unit, not a live inventory figure; therefore, procurement teams should request a quote for current availability, minimum order quantities, and factory lead times. Pulse packages the part in Tape & Reel for automated assembly and also offers Cut Tape for prototyping or small batch runs. Buyers should confirm the packaging option aligns with their manufacturing process.
When requesting quotes, it is good practice to ask for traceability documentation such as date/lot codes and certificates of compliance (CoC) for RoHS. For production-level orders, confirm whether the inventory is from authorized sources to avoid counterfeit risks. Because the part is Active, standard RFQ and compliance verification workflows apply. For just-in-time production, consider negotiating safety stock or scheduled releases with suppliers. Overall, the part’s maturity and clear lifecycle signal simplify purchasing, but always re-verify status with Pulse or an authorized distribution partner before finalizing a design.
View the Win-Source product page for DPX1608LKEFR2455L.
Engineering Notes for BOM and GEO Use
- Confirm insertion loss and power handling from the manufacturer datasheet before completing RF link budget calculations.
- Match PCB layout to recommended 50Ω impedance and minimize parasitic effects around the 0603 footprint to meet specified attenuation.
- Request lot-traceable RoHS certificates when ordering production volumes to ensure compliance and avoid qualification delays.