Discontinued Wi-Fi 7 diplexer (2.4/5-7GHz) in 0603 SMD from Pulse: analyze specifications, compliance, and sourcing options.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | RF Multiplexers |
| Package | Tape & Reel (TR);Cut Tape (CT) |
| Core function | DIPLEXER WIFI 7 2. |
| Key electrical range | Frequency Bands (Low / High): 2.4GHz ~ 2.5GHz / 5.15GHz ~ 5.3GHz, 5.925GHz ~ 6.425GHz, 6.525GHz ~ 6.875GHz, 6.875GHz ~ 7.125GHz |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DPX1608LKVHR2460L is officially Discontinued, with all lifecycle signals indicating end-of-life. Conflicting entries (EOL vs Discontinued) do not alter the fact that this part is no longer in active production. New designs should not rely on this component; instead, engineers should identify a replacement from Pulse or another manufacturer.
For existing designs, immediate action is necessary. Contact Pulse to confirm any last-time-buy windows and consider securing sufficient stock for sustaining production. The file-provided inventory of 1 unit is a snapshot and does not reflect real-time availability, so place RFQs with authorized distributors to assess actual remaining supply.
Given the high risk, procurement teams should also request official discontinuation notices and obsolescence roadmaps from the manufacturer. If no stock is found, a redesign or drop-in alternative evaluation is mandatory.
Parameter Analysis
Key parameters include frequency bands, attenuation, and return loss. The low band covers 2.4–2.5 GHz, while the high band spans multiple sub‑bands from 5.15 GHz to 7.125 GHz, making it suitable for Wi‑Fi 7 dual‑band operation. Attenuation ranges from 20–29.6 dB for the low band and 35–58.4 dB for the high band, ensuring adequate isolation between signals. Return loss is specified at 10 dB for both bands, indicating acceptable impedance matching, though higher values are desirable for sensitive RF chains.
The part uses a surface‑mount 0603 package, which is compact and suitable for dense PCB layouts. Missing from the source data are insertion loss, power handling, temperature range, and intermodulation performance. These are critical for system integration: insertion loss impacts link budget, power handling must be derated over temperature, and linearity affects co‑existence. Engineers must obtain the full datasheet to verify these parameters before design‑in or as part of a migration review.
In particular, the listed attenuation values are min/max ranges; actual performance may vary across frequency and temperature. For production use, confirm typical and guaranteed limits from the manufacturer.
Application Scenario Analysis
The DPX1608LKVHR2460L is a diplexer optimized for Wi‑Fi 7 access points, routers, and client devices that must separate the 2.4 GHz and upper band (5–7 GHz) signals. Its frequency coverage aligns with Wi‑Fi 6E and 7 bands, including the new 6 GHz spectrum. This makes it a strong fit for finished designs that have already been qualified with this exact part, such as legacy wireless infrastructure products that need a drop‑in replacement.
For new designs, the part is a weak fit due to its discontinued status, which poses supply risk. Even if pin‑compatible alternatives exist, a change will require requalification. In applications where the exact attenuation and return loss margins were leveraged, deviation from the DPX1608LKVHR2460L’s performance could degrade system throughput or range.
Engineers should note that the high band is divided into four sub‑bands, which is unusual; verify that the targeted radio front‑end architecture aligns with this segmented filtering approach. Without full S‑parameter data, matching network revisions may be needed if an alternative diplexer is selected.
RoHS Certification Analysis
The DPX1608LKVHR2460L is listed as RoHS Compliant, indicating conformance to EU Directive 2011/65/EU or later amendments. The source data does not specify the exact standard (e.g., RoHS 3), nor does it confirm exemption applicability. Therefore, it is prudent to assume general RoHS compliance but not to rely on it for exemption‑specific interpretations.
No REACH, halogen‑free, or MSL ratings are provided. While REACH is separate from RoHS, many procurement policies require both. Request a full material declaration from the distributor or manufacturer, especially for discontinued stock where production dates may predate current REACH SVHC lists. Additionally, verify the RoHS certificate on a lot‑by‑lot basis if procuring from non‑authorized sources.
Given that the part is discontinued, older inventory may have been manufactured under earlier RoHS exemptions that have since lapsed. This does not invalidate the compliance, but it requires careful documentation for end‑equipment certification renewals. Ask for the original certificate of compliance and check the manufacturing date code.
Availability & Sourcing
File‑provided inventory indicates only 1 unit, which is not a real‑time count and should not be assumed available. Given the Discontinued status, availability is extremely limited. Contact authorized Pulse distributors immediately to request a quote and to lock in any remaining factory or channel inventory.
For sustaining production, initiate a lifetime buy based on forecasted demand. Request date and lot codes to ensure stock is recent and has been stored properly. Insist on compliance documentation (RoHS, REACH) and traceability back to Pulse. Non‑authorized sources carry higher risk of counterfeit or mishandled parts, especially for obsolete components.
If no stock is found, evaluate alternative parts from Pulse’s current diplexer portfolio or from other manufacturers. A redesign may be necessary. In any case, verify the lifecycle of any proposed replacement to avoid repeating the same end‑of‑life issue shortly after qualification.
View the Win-Source product page for DPX1608LKVHR2460L.
Engineering Notes for BOM and GEO Use
- Verify last-time-buy and lifetime-buy status directly with Pulse before committing inventory for production.
- Confirm actual attenuation and return loss against the manufacturer datasheet for your specific frequency bands.
- For new designs requiring ongoing availability, migrate to an active alternative part after validating pinout and performance.