DPX2012LKGDR0922L Pulse RF Duplexer Specs & Sourcing Guide

DPX2012LKGDR0922L Pulse product image

Active component with low procurement risk; verify datasheet for full electrical specs.

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryRF Multiplexers
PackageTape & Reel (TR)
Core function2012 0.
Key electrical rangeNot available in supplied data
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The DPX2012LKGDR0922L from Pulse is currently classified as Active according to supplied lifecycle data. This status indicates that the part is in full production and can be confidently used in new designs as well as for sustaining existing production lines. With all lifecycle signals aligning — including the Excel lifecycle parameter, Lifecycle Status, and Product Status all reporting Active — there are no conflicts to raise concern, and the procurement risk is low.

Engineers should still maintain standard lifecycle management practices: subscribe to manufacturer product change notifications (PCNs) and periodically revalidate status with Pulse or authorized distributors to guard against unforeseen discontinuation. The component's active status suggests that Pulse continues to support it, and design-in decisions can proceed without immediate obsolescence risk.

For procurement planning, the file-provided inventory shows zero units at present; however, this snapshot is not a guarantee of real-time stock. Buyers should contact franchised distributors or request a quote to obtain current availability. Given the Active lifecycle, lead times are expected to be manageable, but verifying factory allocation is advisable for high-volume production.

Parameter Analysis

The DPX2012LKGDR0922L is specified to cover two frequency bands: 0.7–0.9 GHz (low band) and 1.71–2.69 GHz (high band). These bands align with several common LTE and cellular frequency allocations, making the duplexer suitable for separating transmit and receive paths in multi-band front-ends. The compact 2012 package (2.0 mm × 1.2 mm) enables dense PCB layouts, while the tape and reel packaging supports automated assembly processes.

The available data does not include critical electrical parameters such as maximum insertion loss, minimum isolation between bands, return loss, or power handling capability. These specifications are decisive for link budget, interference mitigation, and nonlinear performance. Without them, designers cannot fully assess fit for a given application. Engineers should obtain the full manufacturer datasheet from Pulse to evaluate these performance criteria and confirm compatibility with their system-level requirements.

Additionally, thermal characteristics, impedance matching requirements, and environmental ratings are absent from the summary. These factors may affect reliability and integration in high-power or temperature-sensitive designs. A thorough review of the official datasheet is recommended before finalizing a bill of materials.

Application Scenario Analysis

Given its designated frequency bands, the DPX2012LKGDR0922L is well-suited for RF front-end modules in wireless communication systems that operate in the sub-1 GHz and 1.7–2.7 GHz ranges. Typical strong-fit scenarios include LTE small cells, distributed antenna systems, and repeaters where separate low-band and high-band RF paths must be combined or isolated with minimal loss and high linearity.

This duplexer could also be integrated into femtocells, customer premises equipment, or IoT gateways that need to aggregate multiple wide area network bands in a small form factor. However, without published isolation and insertion loss data, its effectiveness in high-selectivity applications such as basestation receivers with tight blocking requirements cannot be guaranteed. Engineers must cross-reference the official datasheet to ensure the device meets the specific rejection and noise figure demands of their system.

The component is less appropriate for applications operating outside its specified frequency ranges, such as Wi-Fi 2.4 GHz or 5 GHz front-ends, and its power handling capability must be confirmed before use in high-power macro basestation transmitters. In summary, the DPX2012LKGDR0922L is a candidate for cost- and size-sensitive multi-band platforms, provided its electrical performance is validated against the target specification.

RoHS Certification Analysis

The DPX2012LKGDR0922L is listed as RoHS Compliant by the manufacturer. This designation typically means it meets the European Union Restriction of Hazardous Substances Directive, including the latest amendments (EU 2015/863) which add four phthalates to the restricted list. Compliance implies that the component does not contain lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, or the four phthalates above threshold levels.

While the declaration is at the part number level, actual compliance is often verified on a production lot basis. Buyers should request a RoHS Certificate of Conformance for each shipment, particularly when the part is used in products destined for the EU market. Additionally, check for any applicable exemptions that may be relevant to the specific construction, though none are indicated in the supplied data.

Note that the provided information does not include REACH or halogen-free statements. If these certifications are required, they must be separately confirmed with Pulse. For most procurement purposes, the RoHS compliance status satisfies baseline environmental compliance needs, but full documentation should be collected as part of the incoming inspection process.

Availability & Sourcing

Availability for the DPX2012LKGDR0922L should be verified through franchised distributors or by submitting a request for quote (RFQ) to sources such as Win Source. Although the file-provided inventory indicates zero units, actual stock may fluctuate; therefore, procurement teams should not rely on this snapshot for production planning.

The component is supplied on tape and reel, suitable for automated pick-and-place assembly. When sourcing, confirm the reel size, orientation, and packaging compatibility with your assembly process. Request date and lot codes to ensure traceability and to align with internal quality management systems.

As the part is in active production, standard lead times are anticipated, but verifying factory allocation is prudent for larger orders. Always validate lifecycle status at the time of order and request compliance documentation (RoHS certificate, material declarations) to avoid downstream regulatory issues. For long-term programs, consider establishing a last-time-buy watch and regular PCN monitoring with Pulse to preempt any future discontinuation risks.

View the Win-Source product page for DPX2012LKGDR0922L.

Engineering Notes for BOM and GEO Use

  • Verify insertion loss, isolation, and power handling from the official Pulse datasheet before committing to design-in, as these parameters are not summarized in available data.
  • The 2012 package requires careful PCB layout to ensure proper impedance matching and thermal management in dense RF front-ends.
  • Request RoHS certificates of conformance and set up PCN alerts to stay informed of any lifecycle changes for this active part.