Discontinued Pulse diplexer – verify manufacturer status and consider alternatives for new designs
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | RF Multiplexers |
| Package | Tape & Reel (TR) |
| Core function | RF DIPLEXER 2. |
| Key electrical range | Frequency Bands (Low / High): 2.4GHz ~ 2.5GHz / 4.9GHz ~ 5.95GHz |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DPX2012LL89R2455A from Pulse is a discontinued RF diplexer. Both the Excel BOM parameter and the official product status flag it as EOL/Discontinued, leaving no ambiguity about its obsolete status. For procurement teams, this means the part carries high risk for any bill-of-materials that has not already completed a last-time-buy.
Engineers should not specify this diplexer in new designs. Existing products relying on the DPX2012LL89R2455A should immediately assess remaining lifetime requirements and secure whatever inventory can be located. The workbook quantity for this part is shown as zero, which suggests that even residual distributor stock may be exhausted.
Before placing any order, verify the lifecycle status directly with Pulse or an authorized distributor. Even if a small quantity is found, treat it as a bridge to an active alternative rather than a reliable supply.
Parameter Analysis
The DPX2012LL89R2455A targets dual-band applications with a low band of 2.4–2.5 GHz and a high band of 4.9–5.95 GHz. Minimum attenuation is specified at 20 dB for both bands, while return loss is 10 dB minimum at each port. These values are typical for integrated diplexers in compact footprints.
The 10 dB return loss is acceptable for many consumer RF designs but may be marginal for systems with strict VSWR requirements. The absence of a maximum attenuation figure means adjacent channel rejection or out-of-band suppression cannot be fully predicted from the available data. Critical missing parameters include insertion loss, absolute isolation between low and high ports, power handling capability, characteristic impedance (usually 50 Ω, but unconfirmed), and operating temperature range.
Before committing to an alternate part or a last-time buy, obtain the full Pulse datasheet to validate these parameters against your link budget and environmental requirements. Pay particular attention to insertion loss at the band edges, as that directly affects system sensitivity and transmit efficiency.
Application Scenario Analysis
The frequency bands of the DPX2012LL89R2455A align with common ISM and Wi-Fi allocations: 2.4 GHz for Bluetooth/Wi-Fi and 5 GHz for additional Wi-Fi channels. This makes it suitable for dual-band access points, routers, IoT gateways, and similar consumer or enterprise equipment where a single antenna serves both bands.
With 20 dB attenuation and 10 dB return loss, the part is adequate for medium-performance combiners and deplexing in non-critical signal paths. However, it would be less suitable for applications requiring high isolation between bands or handling high transmit power, such as infrastructure base stations or military radios. The small 0805 package restricts thermal dissipation, so power levels should be verified.
Given its discontinued status, this diplexer should only be considered for sustaining existing designs already qualified with the DPX2012LL89R2455A. For any new product development, an active alternative with similar electrical footprint and confirmed long-term availability is strongly advised.
RoHS Certification Analysis
The DPX2012LL89R2455A is marked as RoHS Compliant according to the available data. No specific EU directive revision is cited, so compliance with the original RoHS (2011/65/EU) is the minimum assumption. Whether it meets the stricter RoHS 3 (EU 2015/863) phthalate restrictions is not documented in the provided source.
There is no mention of REACH, halogen-free, or MSL ratings. For procurement in regions with environmental compliance audits, request a full material declaration or certificate of compliance from Pulse. Lot-level documentation becomes even more critical for discontinued parts, as older production dates may predate newer regulatory thresholds.
If RoHS compliance must be demonstrated for import or contractual reasons, treat the generic compliance flag as preliminary. Cross-check with the manufacturer’s latest PCN and environmental data before finalizing any purchase.
Availability & Sourcing
The DPX2012LL89R2455A is officially discontinued, and the workbook inventory count is zero. This indicates that standard distribution channels likely hold no stock. Engineers and buyers should approach sourcing with caution.
For immediate needs, contact Pulse’s authorized distribution network or aftermarket brokers to inquire about any remaining allocated inventory. Request a quote that includes date/lot codes, packaging origin, and a compliance certificate. Since lifecycle status is already discontinued, any quantity found should be treated as end-of-life surplus and not relied upon for long-term production.
For future requirements, identify a pin-compatible, active replacement or accept a redesign. Verify the candidate’s lifecycle with the manufacturer before qualifying it in your system. No pricing information is available for the DPX2012LL89R2455A, and any quote will be subject to residual stock conditions.
View the Win-Source product page for DPX2012LL89R2455A.
Engineering Notes for BOM and GEO Use
- Verify minimum 20dB attenuation across full temperature and frequency range per datasheet.
- Confirm 0805 6-pad footprint compatibility and PCB layout guidelines.
- For new designs, select an active diplexer with guaranteed availability and support.