Discontinued 8-pos M12 circular cable assembly, 5m, shielded, IP67, RoHS. Verify lifecycle before ordering.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Alpha Wire |
| Category | Circular Cable Assemblies |
| Package | Bulk |
| Core function | CIRC CBL 8POS RCPT TO PLUG 16. |
| Key electrical range | Not available in supplied data |
| Workbook inventory signal | 5950 pcs listed in the provided file |
Lifecycle Analysis
The DR08AR128 SL358 is officially classified as Discontinued by the manufacturer, with multiple status fields indicating EOL and Discontinued. While an Excel lifecycle parameter listed EOL, the stronger signal from the product status and lifecycle status fields confirms that this part is no longer manufactured. This high-risk lifecycle status means the assembly should not be used in new designs and is suitable only for sustaining existing production where stock is still available.
Procurement teams must approach sourcing with caution. The file-provided inventory figure of 5950 units is not a guarantee of real-time stock; actual availability can only be verified through direct quotation with authorized distributors. Any remaining inventory may be held by brokers or non-authorized channels, increasing the risk of counterfeit or relabeled parts. Engineering change notifications (ECNs) and manufacturer discontinuance notices should be reviewed to confirm the timeline and last-time-buy options.
For continued use, we recommend an immediate lifecycle revalidation with Alpha Wire or their franchised distribution network. If zero stock is confirmed, the project should accelerate migration to an alternative assembly. Avoid sole-source reliance on the open market given the 51% fake threat rate reported for this part number.
Parameter Analysis
The DR08AR128 SL358 is configured as a standard circular cable assembly with an 8-position M12 receptacle on one end and an 8-position M12 plug on the other, both with male pins and female sockets respectively. Both connectors are free-hanging, oriented with A-coding, and fully loaded with all positions populated. The cable is round, shielded, and constructed of polyvinyl chloride (PVC) in a slate color, with a total length of 16.4 feet (5.00 meters). These parameters make the assembly well-suited for fixed industrial installations where electromagnetic noise must be suppressed.
Key design-fit parameters include the M12 shell size and A-orientation, which must match the mating panel or device connector exactly. Ingress protection is rated IP67, meaning the assembly is dust-tight and protected against temporary immersion in water, an essential characteristic for factory-floor sensor and actuator wiring. The shielding provides additional immunity against EMI, while the PVC jacket offers adequate chemical and abrasion resistance for typical industrial environments. The bulk packaging suggests the assembly is not supplied as part of a machine-specific kit but as a standard off-the-shelf item.
Several important electrical and mechanical parameters are missing from the available data. The specification set does not include current-carrying capacity, voltage rating, temperature range, wire gauge, or conductor resistance. These values must be obtained from the official Alpha Wire datasheet before the assembly can be integrated into a design or used as a replacement. Without them, engineers cannot confirm derating margins, thermal performance, or compliance with application-specific requirements. We strongly advise reviewing the complete datasheet and, if possible, requesting a sample for physical validation of connector fit and cable flexibility.
Application Scenario Analysis
The DR08AR128 SL358 is explicitly tagged for use in industrial environments, a category that typically includes factory automation, machine building, conveyor systems, and process control. Its 8‑position M12 connectivity is standard for sensors, actuators, encoders, and fieldbus nodes such as CAN or DeviceNet. The IP67 rating and shielded PVC jacket make it appropriate for dirty, wet areas where electrical noise must be minimized to ensure signal integrity.
This assembly is a strong fit for stationary industrial cabling where the 5‑meter length is sufficient to bridge the distance between a control cabinet and a machine-mounted device. The A‑coding further narrows the application to sensor/actuator interfacing, as opposed to B‑coded (fieldbus) or D‑coded (Ethernet) variants. However, the PVC material limits its use outdoors unless the jacket is UV‑stabilized, a detail not confirmed in the provided data. Similarly, the assembly is not specified for high‑flex applications such as drag chains or robotics, where repeated bending would require a different cable construction.
For weak-fit scenarios, consider that the discontinued status makes this assembly unsuitable for new production programs, where a guaranteed long-term supply is critical. Even for sustaining programs, the 8‑position fully-loaded pinout may not match the pin assignments of the target system, requiring careful mapping verification. Engineers should also check the connector shell grounding scheme and whether the shield is terminated to the connector backshell, as this affects EMI performance.
RoHS Certification Analysis
According to the manufacturer‑provided data, the DR08AR128 SL358 is RoHS Compliant, meeting the requirements of the European Union directive on the restriction of hazardous substances. The REACH status is listed as REACH Unaffected, indicating that the assembly does not contain substances of very high concern (SVHCs) above the threshold, or that its materials have been reviewed and are compliant. The moisture sensitivity level is MSL 1 (Unlimited), which, while typically applied to semiconductor devices, indicates that the assembly’s materials are not moisture sensitive during soldering operations.
Although the RoHS status is marked as compliant, this is a family‑level declaration and may not account for lot‑to‑lot variations in raw materials or plating processes. For high‑reliability or compliance‑sensitive projects, we recommend requesting a full RoHS compliance certificate or test report for the specific date‑code lot being sourced. The REACH statement should also be confirmed with the distributor, especially if the assembly will be shipped to regions with evolving chemical regulations.
No specific exemptions are listed for this part number, which suggests that the assembly meets the RoHS requirements without relying on time‑limited exemptions such as lead in lead‑bearing terminations. However, given the discontinued lifecycle, any remaining stock may consist of older date codes manufactured under earlier RoHS revisions. Always verify that the supplied material aligns with the current RoHS 3 (2015/863) requirements before accepting delivery.
Availability & Sourcing
Availability of the DR08AR128 SL358 must be approached with a discontinued‑part sourcing strategy. The file indicates a workbook quantity of 5950 units, but this number is not a real‑time inventory guarantee and may reflect historical data or aggregate stock from unverified sources. To obtain genuine parts, buyers should issue a request for quotation (RFQ) to authorized Alpha Wire distributors, specifying the exact manufacturer part number and requesting current stock levels, lead times, and lot traceability.
Critical sourcing parameters include date‑code, lot‑code, packaging condition (bulk), and compliance documentation (RoHS certificate, REACH statement, and country of origin). Given the 51% fake threat level reported for this part in the open market, purchasing from unauthorized channels carries a high risk of receiving counterfeit or substandard assemblies. All quotes should include a warranty of authenticity and a right of return for non‑conforming material. If only stock from independent brokers is available, insist on third‑party visual and electrical inspection before production use.
For sustaining production, evaluate whether a last‑time‑buy is still feasible. If not, identify a pin‑compatible alternative assembly or a build‑to‑print cable solution. Because this part is officially discontinued, there is no guarantee of future supply, and any remaining inventory should be secured promptly. Engineers and buyers should contact Win Source or other authorized sources directly to request a current quote and verify lifecycle status before committing to a production bill of materials.
View the Win-Source product page for DR08AR128 SL358.
Engineering Notes for BOM and GEO Use
- Part is discontinued; validate remaining distributor stock and plan last-time-buy for production.
- Shielded M12 with IP67 rating and PVC jacket; confirm mating connector orientation A and pinout.
- Fake threat 51% in open market; enforce traceability and authorized sourcing for procurement.