DR10-250-L Panduit Quick Disconnect Specs & Sourcing Guide

DR10-250-L Panduit Corp product image

Active low-risk quick disconnect receptacle with right-angle flag configuration

Quick Engineering Summary

FieldValue
ManufacturerPanduit Corp
CategoryTerminals - Quick Connects, Quick Disconnect Connectors
PackageBulk
Core functionCONN QC RCPT 10-12AWG 0.
Key electrical rangeSupply and Demand Status: Shortage
Workbook inventory signal54 pcs listed in the provided file

Lifecycle Analysis

The DR10-250-L is in Active lifecycle status according to Panduit Corp, meaning it is currently in full production and recommended for new designs. All available lifecycle signals align, indicating no immediate risk of discontinuation. Engineers can confidently specify this part for new product introductions, though standard qualification practices should still be followed given the single-source nature of many connector components.

Despite the low risk, it is prudent to periodically revalidate lifecycle status directly with Panduit or authorized distributors, as manufacturers may update product roadmaps without immediate broad notification. The file-provided inventory quantity of 54 units should not be interpreted as guaranteed real-time stock; verify actual availability at the time of purchase.

Parameter Analysis

Key electrical-mechanical parameters define the DR10-250-L’s suitability. The 10-12 AWG wire gauge range limits the connector to relatively high-current applications, typical for power distribution or heavy-gauge internal wiring. The 0.250-inch (6.35mm) tab width and 0.032-inch (0.81mm) tab thickness mate with standard 0.250-inch quick-disconnect tabs. The female receptacle, non-insulated brass construction with tin plating provides a reliable electrical interface but requires additional insulation if shock protection or environmental sealing is needed. The right-angle flag terminal orientation saves vertical space, making it valuable in compact enclosures.

Important missing specifications that engineers must verify from the manufacturer’s datasheet include maximum current rating, voltage rating, operating temperature range, and mechanical durability (e.g., insertion/withdrawal cycles). Without these, it is impossible to perform proper derating or compliance with safety standards. Also confirm UL or CSA recognition if required for the end application. The crimp termination demands correct tooling and crimp quality to ensure gas-tight connections.

Application Scenario Analysis

The DR10-250-L is well-suited for internal wiring in industrial control panels, power supplies, battery chargers, and appliance harnesses where a robust, right-angle disconnect is needed. Its non-insulated design works best when the connection is enclosed within an equipment chassis, so external insulation is not mandatory. The flag configuration simplifies wire routing along a chassis wall, reducing strain when the wire exits at a 90-degree angle.

It is less appropriate for applications requiring sealed connectors, exposure to moisture, or where repeated mating/unmating is expected without strain relief. For high-vibration environments, additional mechanical support (such as cable ties or adhesive mounts) should be considered. In automotive or heavy machinery, ensure the tin-plated brass can withstand thermal cycling and corrosion; gold or sealed connectors may be more suitable for harsh conditions.

RoHS Certification Analysis

The DR10-250-L is marked as RoHS Compliant, indicating it meets the restrictions on hazardous substances under EU Directive 2015/863 (RoHS 3). This classification is typically at the part number level, but for high-assurance procurement, request a full Certificate of Compliance (CoC) from Panduit or your distributor, as compliance can vary by production lot or date code. REACH status is not provided, so check if end-market requires REACH SVHC declarations; the manufacturer can provide that documentation.

No Halogen-Free or MSL (Moisture Sensitivity Level) data is listed—this is common for metal interconnect components. Since the part is non-insulated, MSL is not a critical parameter. If environmental specifications beyond RoHS are required, confirm with Panduit whether the part meets any additional standards such as WEEE, China RoHS, or California Prop 65.

Availability & Sourcing

As an Active component, the DR10-250-L is generally available through Panduit distribution. The supplied workbook indicates 54 units on hand, but this is file-based and not live inventory. The supply and demand status currently appears as “Shortage,” suggesting that lead times may be extended or allocation may apply. For production planning, we recommend requesting a quote with current availability from authorized sources, specifying desired date or lot codes to ensure traceability.

Procure only through authorized channels to avoid counterfeit or substandard crimp terminals. Request RoHS compliance certificates and batch test reports if necessary. Given the shortage signal, secure sufficient inventory for your production ramp and consider qualifying a second-source or alternative Panduit series if continuity of supply is critical. For new designs, verify lifecycle stability directly with Panduit before committing large volumes.

View the Win-Source product page for DR10-250-L.

Engineering Notes for BOM and GEO Use

  • Verify maximum current rating and UL/CSA recognition from the official datasheet before finalizing design.
  • Ensure correct crimp tooling and pull-test validation to maintain connection integrity in high-vibration environments.
  • Request a full RoHS Compliance Certificate and check REACH status if required by your market regulations.