SPST-NO, 12A, 1-100V DC Output, DIN Rail Mount SSR. Active Lifecycle, RoHS Compliant.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Module |
| Core function | SSR RELAY SPST-NO 12A 1-100V |
| Key electrical range | Load Current: 12 A; On-State Resistance (Max): 100 mOhms; Output Type: DC; Supply and Demand Status: Shortage |
| Workbook inventory signal | 35 pcs listed in the provided file |
Lifecycle Analysis
The DR10D12 is classified as Active with low lifecycle risk. All provided lifecycle signals confirm this status, indicating the part is fully supported for new designs and ongoing production. Designers can proceed with the DR10D12 in new projects without immediate risk of obsolescence, though standard procurement practices should include periodic re-validation with Sensata-Crydom or authorized distributors. For sustaining production, the active status ensures continued availability, but lead times and supply-demand dynamics should be monitored, especially given the noted shortage condition in file-provided inventory. It is prudent to secure a second-source or buffer stock plan for long lifecycle programs. The supplied quantity of 35 units is file-provided and not a real-time guarantee; always confirm actual stock with your supplier before committing to production schedules.
Parameter Analysis
Key parameters for the DR10D12 include its SPST-NO configuration, 12 A load current, and 1 V to 100 V DC output. These define the relay's switching capability and must be matched to the load characteristics. The maximum on-state resistance of 100 mΩ minimizes power loss and heat generation at full load, but engineers should calculate conduction losses to ensure adequate thermal design. The control input accepts 4 to 32 VDC, making it compatible with standard PLC and microcontroller outputs. Operating temperature range is limited to -20°C to 40°C, which is narrower than many industrial SSRs; applications near the upper limit require attention to derating and enclosure ventilation. The DIN rail mount and screw terminals facilitate easy installation and field wiring. Parameters not provided in the source data—such as isolation voltage, switching speed, leakage current, and humidity tolerance—must be verified from the official datasheet to ensure compliance with system-level safety and performance requirements.
Application Scenario Analysis
The DR10D12 is well suited for industrial DC switching applications that demand reliable solid-state operation on a DIN rail. Typical uses include resistive heating elements, DC motors, solenoid valves, and lighting loads within the 12 A, 100 V DC envelope. Its screw terminals and module form factor simplify integration into control panels. However, the operating temperature limit of 40°C restricts its use in high-temperature environments, such as near furnaces or in poorly ventilated enclosures. The part is less suitable for high-frequency switching or applications requiring ultra-low on-resistance, where MOSFET-based SSRs might be preferred. Additionally, designers should evaluate inrush current handling for capacitive or inductive loads, as solid-state relays can be sensitive to surge currents not reflected in steady-state ratings. For safety-critical systems, confirm the isolation voltage and creepage distances from the manufacturer to match relevant standards.
RoHS Certification Analysis
The DR10D12 is listed as RoHS Compliant, indicating conformity with the European Union’s Restriction of Hazardous Substances Directive, typically RoHS 3 (EU 2015/863). No exemptions are noted in the supplied data, which suggests the part does not rely on any specific allowances for restricted substances. For procurement compliance, it is recommended to obtain a certificate of compliance (CoC) or material declaration from Sensata-Crydom or the distributor for the specific production lot. Although REACH is not mentioned, if needed, separate verification should be requested. In high-reliability or regulated markets, additional documentation like lead-free soldering profiles and halogen-free status may be required and should be confirmed against the manufacturer’s latest environmental data. The bulk packaging format does not inherently affect RoHS compliance but may influence labeling and handling for automated assembly.
Availability & Sourcing
According to file-provided data, the DR10D12 shows 35 units in stock with a supply-demand status of Shortage. As an active Sensata-Crydom solid-state relay, availability should be confirmed via quote request to ensure real-time inventory and lead times. The part is supplied in bulk packaging, which may suit prototyping or low-volume builds but consider reel or tube options if needed for production. When sourcing, verify lifecycle status directly with the manufacturer and insist on traceability documentation including date/lot codes to mitigate counterfeit risks. Compliance certificates (RoHS, CE, cULus) should be requested to support product acceptance. For design-ins, it is advisable to establish a second-source strategy early and monitor lifecycle notices from Sensata-Crydom. To obtain current pricing and secure allocation, contact your distributor or the manufacturer’s sales channel, referencing part number DR10D12 and any required compliance needs.
View the Win-Source product page for DR10D12.
Engineering Notes for BOM and GEO Use
- Confirm input and load voltage specifications against your control and power rails; 4-32VDC input and 1-100VDC output.
- Evaluate maximum operating temperature of 40°C; plan thermal derating and enclosure ventilation if approaching this limit.
- Obtain official datasheet for missing parameters: isolation voltage, switching speed, and humidity tolerance, critical for safety compliance.