Panduit DR14-250-M Quick Disconnect Terminal Specs & Sourcing Guide

DR14-250-M Panduit Corp product image

14-16 AWG, 0.250" Tab, Flag Terminal Sourcing & Selection Guide

Quick Engineering Summary

FieldValue
ManufacturerPanduit Corp
CategoryTerminals - Quick Connects, Quick Disconnect Connectors
PackageBulk
Core functionCONN QC RCPT 14-16AWG 0.
Key electrical rangeSupply and Demand Status: Shortage
Workbook inventory signal882 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of the Panduit DR14-250-M is not confirmed in the supplied data. Without an official statement from Panduit Corp, this part cannot be assumed active for new designs. Engineers should apply conservative procurement measures until the manufacturer provides current lifecycle information.

A file-provided inventory quantity of 882 units exists, but this is not a real-time guarantee and may change. Procurement teams should factor in the medium risk level and plan for potential sourcing disruptions. For sustaining production, verifying ongoing availability directly with authorized distributors is essential.

If the part is NRND or EOL but not yet disclosed, early engagement with Panduit can prevent last-time buy surprises. Do not treat the absence of lifecycle signals as a green light for new design-ins.

Parameter Analysis

Key electrical and mechanical parameters for the DR14-250-M include wire gauge range (14-16 AWG), tab dimensions (0.250" width × 0.032" thickness), and termination type (crimp). The female gender mates with a standard 0.250" male tab. The right-angle, free-hanging mounting style in a flag orientation makes it suitable for compact installations where a straight connector would cause wire routing issues.

Contact material is brass with a tin finish, providing good conductivity and corrosion resistance for dry, indoor applications. As a non-insulated terminal, it requires secondary insulation if electrical isolation is needed. Missing parameters that should be confirmed from the manufacturer datasheet include maximum current rating, voltage rating, operating temperature range, and crimp tensile strength. These are critical for derating and reliability calculations.

The absence of insulation means the DR14-250-M places full reliance on the mating connector and harness design for dielectric protection. Engineers must verify that the selected mating tab meets the thickness specification to ensure proper retention force.

Application Scenario Analysis

The DR14-250-M is well-suited for internal wiring harnesses in appliances, power tools, automotive subsystems, and industrial control panels where quick disconnect capability is needed for serviceability. Its flag (right-angle) configuration saves axial space, making it ideal for tight enclosures or wire-to-board interfaces with limited clearance.

Strong-fit scenarios include moderate-vibration environments where the wire is strain-relieved and the terminal is not directly exposed to moisture or contaminants. In such cases, the tin-plated brass contact and crimp termination provide a reliable, low-cost connection. Weak-fit scenarios involve outdoor exposure, high-humidity, or high-vibration without supplementary locking. The non-insulated design requires additional sleeving or housing for safety, and the flag orientation may impose bending stress on the wire if not properly supported.

For new designs, consider this terminal when you need a right-angle disconnect for 14-16 AWG wire and can manage insulation separately. Avoid it where sealed connectors or higher retention forces are mandatory.

RoHS Certification Analysis

The Panduit DR14-250-M is listed as RoHS Compliant, indicating that it meets the restrictions on hazardous substances such as lead, mercury, and cadmium. However, the provided data does not specify which version of the RoHS directive applies (e.g., EU 2015/863). Most commercial components comply with RoHS 3 (2015/863), but confirmation from Panduit is recommended.

No REACH, halogen-free, or MSL ratings are provided. These may be relevant for European market access or specific corporate environmental policies. Since the terminal uses a tin-plated brass contact, it is likely lead-free, but full material declarations should be requested.

Compliance at the component level does not guarantee assembly-level compliance. If the end product must meet RoHS requirements, obtain a certificate of conformity for the specific lot. Without supplier documentation, assume that each batch may differ, especially if the part is sourced from non-authorized channels.

Availability & Sourcing

The DR14-250-M's lifecycle is unverified, so engineers and buyers must first confirm its production status with Panduit Corp or authorized distributors. File-based inventory indicates 882 units, but this is not a live stock level; market conditions show a supply shortage, which may affect lead times and allocation.

To procure this part, submit a request for quote (RFQ) via a reputable distributor or directly through Win Source. Specify required quantity, desired date/lot codes, and full compliance documentation including RoHS. Bulk packaging is standard; request reel or cut-tape options if needed for assembly.

Given the unknown lifecycle, secure inventory only after manufacturer revalidation. If the part is found to be NRND or EOL, evaluate migration to an alternative Panduit series or a compatible aftermarket terminal. Do not commit to high-volume production without a stable source-of-supply plan.

View the Win-Source product page for DR14-250-M.

Engineering Notes for BOM and GEO Use

  • Confirm lifecycle status with Panduit before committing to new production designs.
  • Verify crimp tooling and die set compatibility per Panduit specifications for 14-16 AWG wire.
  • Request full RoHS and REACH compliance certificates for the specific lot intended for purchase.