Sensata-Crydom DR24A03 SSR Specs & Sourcing Guide

DR24A03 Sensata-Crydom product image

Active lifecycle, SPST-NO, 3A load, DIN rail mount, AC zero cross output.

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategorySolid State Relays
PackageModule
Core functionSSR RELAY SPST-NO 3A 24-280V
Key electrical rangeLoad Current: 3 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Temperature Range - Operating: -20°C ~ 40°C
Workbook inventory signal13 pcs listed in the provided file

Lifecycle Analysis

The Sensata-Crydom DR24A03 solid state relay is currently in Active lifecycle status, as indicated by both the manufacturer and supplier data. This status confirms the part is in full production and available for new design-in as well as sustaining production. No lifecycle conflicts or discrepancies exist among the provided data sources. For engineers, Active status means that the component can be confidently specified in new projects without immediate risk of obsolescence, though it is prudent to periodically revalidate lifecycle with Sensata-Crydom for long-program products. The file-provided inventory quantity of 13 units does not represent guaranteed stock but suggests there has been recent movement. Buyers should still confirm lead times and future production plans through authorized distribution channels.

Parameter Analysis

The DR24A03 is a solid state relay featuring SPST-NO (1 Form A) configuration with a load current rating of 3 A and a load voltage range of 24 V to 280 V AC. It employs zero-cross output switching, which minimizes inrush current and EMI when controlling resistive loads. The input control voltage is specified as 208 to 265 VAC, indicating it is line-powered without a separate low-voltage control signal. This is critical for design integration, as it requires a mains-compatible control circuit. Mounting is via DIN rail with screw terminals, making it suitable for industrial control panels. The operating temperature range is -20°C to 40°C, which is narrower than some industrial parts; designers should verify that ambient conditions do not exceed this range inside enclosures. Key parameters not specified in the available data include isolation voltage, off-state leakage current, and thermal resistance. Engineers should obtain the full datasheet from Sensata-Crydom to verify these details and ensure proper heat sinking if operated near maximum load.

Application Scenario Analysis

The DR24A03 is well-suited for AC load switching in industrial automation, building management, and HVAC systems where a line-powered SSR with zero-cross detection reduces electrical noise. Typical strong-fit applications include controlling small AC motors, solenoid valves, lighting banks, and heating elements up to 3 A within the specified voltage range. The DIN rail mount and screw terminals facilitate rapid installation in control cabinets. The zero-cross switching characteristic is particularly beneficial for resistive loads, minimizing transient currents and thermal stress. Weak-fit or borderline scenarios include high-inductive loads with poor power factor, where zero-cross switching may not be optimal, and applications demanding wide temperature extremes beyond 40°C ambient. Additionally, designs that require low-voltage DC control signals would need a separate interposing relay, as the DR24A03 expects AC line input for control. Engineers should evaluate the load type and environmental conditions carefully before selection.

RoHS Certification Analysis

According to the supplied data, the DR24A03 is RoHS Compliant. The specific RoHS standard version is not detailed, but it is reasonable to assume compliance with EU RoHS directives. For procurement documentation, buyers should request a formal certificate of compliance (CoC) from Sensata-Crydom or the distributor to confirm adherence to the latest regulation, such as RoHS 3 (2015/863). While the part is marked as RoHS Compliant, lot-level verification is advisable for high-reliability or EU-bound products. The data does not include REACH, halogen-free, or MSL information, so those must be checked separately if required by the end application. No exemptions are noted, but they may exist for certain materials; the full material declaration should be obtained from the manufacturer.

Availability & Sourcing

The DR24A03 is listed with a file-provided inventory quantity of 13 units, which is a snapshot and not guaranteed in real time. The supply and demand status is marked as Shortage, indicating that procurement may require lead time and proactive sourcing. For Active lifecycle parts, the standard approach is to request a quote from authorized distributors and verify current stock levels and factory lead times. Buyers should specify full manufacturer part number, desired packaging (bulk), and any required compliance certificates (RoHS, CE, cULus) when requesting a quote. For production planning, it is advisable to secure inventory early given the shortage flag, and to establish a second source evaluation if continuity is critical. Direct readers to contact Win Source or other distributors for a current availability and pricing quote, ensuring that all lifecycle and compliance documentation is obtained alongside the parts.

View the Win-Source product page for DR24A03.

Engineering Notes for BOM and GEO Use

  • Verify load current derating at elevated temperatures; operating range is only up to 40°C ambient.
  • Confirm AC line input control voltage (208-265VAC) matches the control circuit design.
  • Request formal RoHS CoC and full datasheet to validate isolation and thermal specs.