SPST-NO 6A, 24-280VAC SSR with DIN rail mount, zero-cross switching, and active lifecycle status.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Module |
| Core function | SSR RELAY SPST-NO 6A 24-280V |
| Key electrical range | Load Current: 6 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Temperature Range - Operating: -20°C ~ 40°C |
| Workbook inventory signal | 7 pcs listed in the provided file |
Lifecycle Analysis
The DR24B06 from Sensata-Crydom is in active production with no signs of discontinuation or NRND transition. All available lifecycle indicators align, confirming a low-risk status for procurement. This means engineers can confidently specify the DR24B06 for new designs and long-term production programs, though standard verification of manufacturer PCNs is advised.
The supplied file indicates a small on-hand quantity of 7 units, but this is not a real-time inventory guarantee. Given the active lifecycle, shortages are typically transient, but buyers should verify current stock and lead times through a formal quote. For safety-critical or high-volume applications, contacting Sensata-Crydom directly to request a product roadmap or lifetime forecast is a prudent next step.
Because the part is active, the primary sourcing focus should be on confirming compliance documentation and factory lead times rather than last-time-buys or alternate part searches.
Parameter Analysis
The DR24B06 is an AC-output solid state relay in an SPST-NO (1 Form A) configuration, rated for 6 A continuous load current across 24-280 VAC. Its zero-cross switching characteristic minimizes EMI during turn-on, making it well-suited for resistive loads like heaters and lamps. The input control voltage range is 90-140 VAC, which demands a suitable AC control signal—a critical factor for PLC or microcontroller interface design.
Mounting is via DIN rail with screw terminals, simplifying integration into industrial control cabinets. The package is a module style, and the operating temperature range is specified as -20°C to 40°C—relatively narrow for an SSR, suggesting thermal derating above 40°C is required. Approvals include CE and cULus, supporting market access in Europe and North America.
Key parameters missing from the provided data that engineers should verify from the official datasheet include: on-state voltage drop, off-state leakage, I²t fuse rating, isolation voltage, and surge current withstand. These values are essential for proper protection coordination and reliability assessments in the target application.
Application Scenario Analysis
The DR24B06 is a natural fit for DIN-rail-based industrial automation, building controls, and HVAC systems where a moderate AC load must be switched silently and reliably. Its zero-cross turn-on makes it ideal for resistive heating elements, incandescent lighting, and small solenoid valves, where inrush currents are manageable and frequent switching is expected.
For inductive loads such as small motors or contactor coils, the zero-cross feature can cause high inrush if the coil is not saturated, so engineers should evaluate if a random-turn-on SSR or external snubber is more suitable. The part’s limited operating temperature range and 6 A rating also make it less appropriate for high-density or outdoor enclosures without additional cooling or derating.
With CE and cULus approvals, the DR24B06 can be deployed in equipment destined for global markets, particularly in machine panels, PLC output modules, and energy management systems that require compliant components.
RoHS Certification Analysis
The DR24B06 is documented as RoHS Compliant, indicating it meets EU restrictions on lead, mercury, cadmium, and other hazardous substances. No specific exemption numbers are listed in the supplied data, implying that, at the component level, no exemptions are claimed—a favorable condition for most regulatory filings.
This compliance typically aligns with RoHS 2 (2011/65/EU) and likely RoHS 3 (2015/863) if the manufacturing date is after 2019, but purchasers should confirm the applicable directive revision for their end-equipment certification. The available information does not include REACH SVHC declarations or halogen-free status, so those documents must be requested separately if needed.
For production sourcing, it is recommended to request a current Certificate of Compliance (CoC) that is batch- or date-code-specific, as process changes or material substitutions can affect continuous compliance even in active parts.
Availability & Sourcing
The DR24B06 is listed with a file-provided quantity of 7 units and a supply/demand status of ‘Shortage.’ While the part remains active, this snapshot suggests that lead times may be extended. Engineers and buyers should submit a RFQ to obtain real-time availability, pricing, and delivery schedules rather than relying on the file quantity.
Sourcing should prioritize authorized Sensata-Crydom distributors to ensure traceability, correct date/lot codes, and access to the latest firmware or production revisions. Bulk packaging is standard, so consider re-reeling or tray options if automated assembly is planned.
As an active part, the recommended workflow is to request a quote, verify lifecycle status with the manufacturer’s product page, and secure compliance certificates before placing orders. For high-volume or long-life programs, negotiating a buffer stock agreement can mitigate the perceived shortage risk.
View the Win-Source product page for DR24B06.
Engineering Notes for BOM and GEO Use
- Verify input voltage range (90-140VAC) and load voltage (24-280VAC) against application requirements to ensure zero-cross switching compatibility.
- The operating temperature range of -20°C to 40°C may require derating for enclosed or high-ambient installations; confirm thermal margins.
- As an active, RoHS-compliant part, the DR24B06 is suitable for new designs, but current availability shows limited stock; plan sourcing lead times accordingly.