DRA-CN024D24 Sensata-Crydom Solid State Relay Specs & Sourcing Guide

DRA-CN024D24 Sensata-Crydom product image

Sensata-Crydom DRA-CN024D24: 3.5A DC SSR, DIN Rail Mount, Active Lifecycle

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategorySolid State Relays
PackageModule
Core functionSSR RELAY SPST-NO 3.
Key electrical rangeLoad Current: 3.5 A; Output Type: DC; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 60°C
Workbook inventory signal72 pcs listed in the provided file

Lifecycle Analysis

The DRA-CN024D24 is classified as Active, indicating that the manufacturer continues to fully produce and support it. This status makes the relay suitable for both new designs and ongoing production requirements. No conflicting lifecycle signals were found in the supplied data, so product obsolescence is not an immediate concern.

Despite the Active designation, the inventory file shows only 72 units and lists the supply-and-demand condition as Shortage. This mismatch suggests that market availability may be tight, possibly due to allocation or lead-time extensions. For projects with volume requirements, it is prudent to verify real-time stock levels and obtain lead-time commitments directly from Sensata-Crydom or franchised distributors before locking in the part.

Parameter Analysis

Critical parameters for the DRA-CN024D24 include a load current of 3.5 A and a load voltage range of 0-24 V DC, defining the output side. The control input accepts 15-30 V DC, making it directly compatible with 24 VDC industrial control signals. The SPST-NO (1 Form A) configuration provides a simple normally-open switch, while screw terminals and DIN rail mounting suit typical panel installations.

Several parameters that influence design robustness are not present in the provided data. On-state voltage drop determines power dissipation and thermal management needs. Isolation withstand voltage is critical for safety compliance, and switching speed (turn-on/turn-off) can affect load compatibility. Engineers should obtain the full manufacturer datasheet to review these values and ensure proper derating for the -25°C to 60°C operating temperature range. The DC output type means this relay cannot switch AC loads; verify polarity and flyback protection in inductive DC circuits.

Application Scenario Analysis

Given its DC output and 24 V control, the DRA-CN024D24 fits well in industrial automation systems that use 24 VDC PLC outputs to switch small DC loads. Typical applications include controlling solenoid valves, DC motors, indicator lamps, and heaters in machinery, HVAC, and process control. The DIN rail mounting and screw terminals align with control cabinet wiring practices.

This relay is not intended for AC loads or high-inrush applications; its DC-only output and modest 3.5 A rating limit it to resistive or light inductive DC loads. Without surge current data, avoid loads that could exceed the steady-state rating at turn-on. The 60°C upper operating temperature may require derating in enclosures with poor ventilation. For high-reliability or safety-critical systems, verify the relay’s endurance and failure modes per the manufacturer’s reliability data.

RoHS Certification Analysis

The DRA-CN024D24 is marked as RoHS Compliant, indicating it meets the European Union’s Restriction of Hazardous Substances directive. Typically, this implies compliance with RoHS 3 (EU 2015/863), which restricts ten substances including lead, mercury, and cadmium. The available data does not list any exemptions, so the part likely is fully compliant without reliance on specific exemption categories.

Because environmental compliance can be lot-specific, procurement teams should request a Certificate of Conformance (CoC) or test report for the exact batch when ordering. This is especially important for equipment destined for the EU market. REACH and halogen-free status are not provided; if relevant, confirm them directly with Sensata-Crydom. As a module-level component, MSL is not applicable, simplifying storage and handling.

Availability & Sourcing

The workbook indicates a stock quantity of 72 units, but this is not a live figure and should not be relied upon for immediate purchase decisions. The part is simultaneously showing a Shortage condition, suggesting that supply may be constrained. As the lifecycle is Active, authorized distributors can place factory orders, though lead times may be extended.

To secure the DRA-CN024D24, submit a request for quotation through standard procurement channels. Confirm current availability, factory lead time, and packaging (bulk, screw-terminal module). Request updated lifecycle status from Sensata-Crydom and verify that the RoHS compliance document applies to the offered stock. For prototype or low-volume needs, the reported inventory may be sufficient, but buffer stock is advisable given the shortage signal. Traceability documentation such as date codes and lot numbers should be requested for quality assurance.

View the Win-Source product page for DRA-CN024D24.

Engineering Notes for BOM and GEO Use

  • Ensure load current and voltage stay within 3.5A and 24V DC, and verify that the control voltage supply matches the 15-30VDC input range.
  • Request the manufacturer’s datasheet to obtain missing critical parameters such as on-state voltage drop, isolation withstand voltage, and switching speed before finalizing design.
  • Due to reported shortage and limited file inventory, confirm real-time stock, lead time, and RoHS certificate with an authorized distributor.