Sensata-Crydom DRA-CN240A24 Solid State Relay Specs & Sourcing Guide

DRA-CN240A24 Sensata-Crydom product image

Technical sourcing guide covering lifecycle, parameters, applications, RoHS compliance, and availability for the DRA-CN240A24 SSR.

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategorySolid State Relays
PackageModule
Core functionSSR RELAY SPST-NO 2A 24-250V
Key electrical rangeLoad Current: 2 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 60°C
Workbook inventory signal32 pcs listed in the provided file

Lifecycle Analysis

The Sensata-Crydom DRA-CN240A24 solid state relay is classified as Active in all available lifecycle signals. This status normally indicates that the manufacturer continues full production, with no immediate plans for discontinuation. For design engineers, an Active lifecycle means the part can be considered for new designs and high-volume production, offering confidence in long-term procurement stability.

However, lifecycle status is only one factor in supply chain risk. The file-provided inventory snapshot lists 32 units, but this is not a real-time figure and should be validated with authorized distributors. Additionally, market conditions such as raw material availability or unexpected surges in demand can temporarily affect lead times even for Active components. Periodic rechecking of the manufacturer’s official lifecycle declaration is recommended, especially as the part matures.

The designation ‘Active’ aligns with the listed risk level of low, but procurement teams should maintain standard monitoring for any last-time-buy notices or change notifications from Sensata-Crydom. Engaging directly with the manufacturer or franchised distributors to establish supply agreements can further mitigate risk for sustained production runs.

Parameter Analysis

The DRA-CN240A24’s SPST-NO (1 Form A) configuration and zero-cross switching output define its operational envelope. The load rating of 2 A at 24–250 V AC makes it well-suited for moderate power AC loads, while the DC input control range of 15–30 V simplifies integration with standard industrial control systems. Zero-cross switching reduces inrush current and EMI at turn-on, but engineers should note that this also means the relay only turns on at the zero-cross point of the AC waveform, which may introduce a small delay—typically less than half a cycle.

DIN rail mounting and screw terminals provide robust mechanical installation for industrial control panels, but the operating temperature range of -25°C to 60°C must be respected. Derating guidelines are not explicitly provided in the available data; therefore, designers should consult the manufacturer’s datasheet for current derating curves at elevated ambient temperatures, as well as for thermal resistance values and heatsinking recommendations if the relay is operated near its rated limits in enclosed enclosures.

Several critical parameters are absent from the summary data and must be verified before final qualification: maximum surge current (withstand capability), off-state leakage current, on-state voltage drop, isolation voltage (input-to-output and to case), and compliance with specific safety standards beyond the listed CE, cURus, UR. Request the full datasheet from Sensata-Crydom to fill these gaps and ensure the relay’s ratings align with application safety margins.

Application Scenario Analysis

The DRA-CN240A24 solid state relay from Sensata-Crydom is optimized for DIN rail industrial applications that require silent, wear-free switching of AC loads up to 2 A. Typical strong-fit scenarios include resistive heating elements, small solenoid valves, indicator lamps, and contactor coils in control panels. The zero-cross switching characteristic makes it particularly suitable for resistive loads where EMI suppression and reduced inrush are beneficial. The wide input voltage range also allows direct interfacing with PLC digital outputs or DC power supplies.

In weak-fit or borderline applications, designers should exercise caution. Inductive loads such as motors or transformers can generate back EMF and current transients that exceed the steady-state rating, potentially degrading the SSR’s internal triac or SCR. Although zero-cross switching reduces turn-on stress, it does not account for turn-off transients. Similarly, high switching frequencies (above a few cycles per second) may cause excessive heat buildup due to switching losses, especially if the load current is near maximum. For such cases, a heat sink or a relay with a higher current rating may be necessary.

The relay is rated only for AC output; it cannot switch DC loads. Additionally, the operating temperature range is modest (60°C maximum), so applications in hot industrial environments without forced cooling are not recommended. Where safety approval documentation is critical, the listed certifications (CE, cURus, UR) should be verified as valid for the specific country and installation class, as some approvals may be conditional on proper fusing or enclosure use.

RoHS Certification Analysis

According to the supplied data, the Sensata-Crydom DRA-CN240A24 is marked as RoHS Compliant. This indicates that, at the time of manufacture, the relay meets the European Union’s Restriction of Hazardous Substances directives. While the exact standard revision is not specified, current expectations align with RoHS 3 (EU 2015/863) for most industrial components of this class. Procurement teams should confirm the specific RoHS certification documentation with the supplier to ensure it covers all applicable substance limits.

RoHS compliance does not automatically extend to REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) regulation; the available data lacks a REACH declaration. Therefore, if the end product is destined for the EU market and must meet REACH requirements, a separate REACH statement or certificate should be requested from Sensata-Crydom or an authorized distributor.

Additionally, while the part is marked RoHS compliant, this is often a manufacturer-level declaration and may not be lot-specific. Buyers requiring full material declarations or lot-level compliance evidence for medical, aerospace, or automotive applications should request a detailed compliance certificate for each shipment. For general industrial use, the provided RoHS status is typically sufficient, but added due diligence reduces regulatory risk.

Availability & Sourcing

The DRA-CN240A24 is currently flagged with a Supply and Demand Status of ‘Shortage,’ which suggests that market demand may be outpacing available inventory despite the part’s Active lifecycle. The file-provided stock quantity of 32 units represents a snapshot and is not guaranteed real-time. Engineers and buyers are strongly advised to contact authorized Sensata-Crydom distributors or request a quote through the supplier platform to obtain current lead times and confirm true on-hand availability.

Packaging information indicates bulk packing, so units may be supplied in trays or individual packaging depending on order volume. For production planning, date/lot code traceability should be specified in purchase orders to ensure freshness and facilitate tracking in case of future quality or compliance audits. Because the part is Active, standard sampling and re-reeling services may be available, but these should be confirmed with the supplier.

Given the lifecycle status and the shortage indicator, the recommended sourcing workflow is: request a formal quotation that includes real-time stock, lead time, and country of origin; ask for a copy of the manufacturer’s certificate of compliance (RoHS, and REACH if needed); and consider placing a non-cancellable, non-returnable (NCNR) order only after verifying that the part meets all technical and regulatory requirements. For new designs, securing a supply agreement with a franchised distributor can help ensure continuity if demand tightens further.

View the Win-Source product page for DRA-CN240A24.

Engineering Notes for BOM and GEO Use

  • Verify actual stock levels and lead times directly with authorized distributors before committing to production volumes, as file-provided inventory may not reflect real-time availability.
  • The SPST-NO configuration and zero-cross switching make this relay suitable for AC resistive and general-purpose loads up to 2A, but ensure that the load inrush current does not exceed derated limits.
  • Request full RoHS and REACH compliance certificates from the supplier for lot-level traceability, especially if the design must meet EU environmental directives.