Active solid state relay with SPST-NO, 8A DC load, DIN rail mount
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Bulk |
| Core function | SSR RELAY SPST-NO 8A 1-100V |
| Key electrical range | Load Current: 8 A; On-State Resistance (Max): 10 mOhms; Output Type: DC; Supply and Demand Status: Shortage |
| Workbook inventory signal | 5 pcs listed in the provided file |
Lifecycle Analysis
The DRA1-CMX100D10 solid state relay is currently listed as Active by Sensata-Crydom, with no conflicting lifecycle signals in the supplied data. This status indicates the part is in full production and supported for new designs. For procurement teams, this means standard lead times and roadmap stability are generally expected, though the component is currently flagged as in shortage.
For new design-ins, the Active status provides confidence, but engineers should still verify lifecycle directly through authorized channels. The file-provided inventory of 5 units is a snapshot and not a guarantee of real-time availability. In sustaining production, monitor distributor stock levels and consider alternate sourcing strategies if the shortage persists.
Given the shortage flag, even with an Active lifecycle, we advise procuring samples early and obtaining a manufacturer’s production lifecycle confirmation to avoid unexpected EOL transitions that could affect long-term projects.
Parameter Analysis
Key parameters for DRA1-CMX100D10 include an 8 A DC load current capability and a load voltage range of 1 V to 100 V, making it suitable for low- to medium-power DC switching. The 3–10 VDC input control voltage is compatible with standard logic-level or PLC outputs. The maximum on-state resistance of 10 mOhms ensures low conduction losses, which is critical for thermal management in dense DIN rail enclosures.
The operating temperature range of -20°C to 80°C must be derated based on actual load current and ambient conditions; missing from the data are derating curves and thermal impedance figures. Designers should request these from Sensata-Crydom to ensure safe operation. The screw terminals and DIN rail mount simplify installation in industrial control panels.
Missing but important parameters to verify: isolation voltage (input-to-output and output-to-case), maximum switching frequency, surge current rating, and off-state leakage current. These directly affect reliability and compliance in applications such as motor control or capacitive loads. Always consult the official datasheet before finalizing the circuit design.
Application Scenario Analysis
The DRA1-CMX100D10 excels in DC load switching applications where silent, wear-free operation is required. Strong-fit scenarios include industrial automation, PLC-controlled actuators, solenoids, heaters, and DC motor control within the 8 A/100 V envelope. The DIN rail form factor and screw terminals align with control cabinet installations in manufacturing environments.
Weak-fit scenarios involve AC loads, high inrush capacitive or inductive loads without external snubbing, or operation at the upper extremes of temperature and current simultaneously without derating. The relay is not rated for AC outputs, so it cannot replace AC SSRs. Additionally, the lack of published isolation voltage might limit use in safety-critical circuits requiring reinforced insulation.
For applications in harsh environments (dust, humidity, vibration), verify the module's IP rating and the need for additional enclosures. Engineers should also confirm the relay’s compliance with specific system-level certifications beyond CE and cURus when integrating into UL-listed panels.
RoHS Certification Analysis
RoHS compliance for DRA1-CMX100D10 is ambiguous in the provided data: one field indicates 'RoHS Compliant' while another states 'RoHS Non-Compliant'. This conflict demands direct verification with Sensata-Crydom or an authorized distributor before procurement. Assuming compliance without documented proof can lead to import or market-access issues in regions enforcing RoHS directives.
Typically, a manufacturer’s official datasheet or certificate of compliance supersedes third-party supplier declarations. However, with shortage conditions, it is possible that inventory spans production lots with different compliance statuses. For critical projects, request lot-specific RoHS and REACH documentation along with material composition declarations.
If compliance cannot be confirmed, consider alternate SSR models from Sensata-Crydom’s catalog that are explicitly certified, or prepare exemption documentation if the application qualifies under RoHS exemptions.
Availability & Sourcing
File-provided inventory shows 5 units of DRA1-CMX100D10 with a 'Shortage' supply and demand status. This indicates constrained market availability. While the lifecycle is Active, current allocations may be tight; therefore, buyers should initiate RFQ processes early and validate lead times with multiple distributors.
When sourcing, prioritize authorized Sensata-Crydom distribution to ensure traceability, factory-packaged bulk components, and valid compliance certificates. Request lot and date code information to manage shelf life and revision control. For production quantities, consider negotiating a backlog order and ask for a PCN (Product Change Notification) agreement.
Because of the shortage flag, do not rely on the file-provided quantity for planning. Always request a real-time quote to obtain current pricing and availability. For design-for-success, have a qualified alternate part number vetted, even if not directly interchangeable, to mitigate supply chain risks.
View the Win-Source product page for DRA1-CMX100D10.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance with Sensata-Crydom to resolve conflicting documentation before purchase.
- File-provided inventory indicates a shortage; request a quote for real-time availability and lead time.
- Ensure DC load current does not exceed 8A and consider derating for elevated operating temperatures.