SPST-NO 6A 100V DC DIN-Rail SSR from Sensata-Crydom
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Bulk |
| Core function | SSR RELAY SPST-NO 6A 1-100V |
| Key electrical range | Load Current: 6 A; On-State Resistance (Max): 40 mOhms; Output Type: DC; Supply and Demand Status: Shortage |
| Workbook inventory signal | 7 pcs listed in the provided file |
Lifecycle Analysis
The DRA1-CMX100D6 from Sensata-Crydom is currently listed as Active, indicating that the manufacturer continues to produce and support this solid state relay for new designs and ongoing production. The supplied lifecycle signals align, with no internal contradictions. However, a specification field notes a Supply and Demand Status of 'Shortage,' which suggests that market availability may be constrained even though the component remains in production.
Engineers designing the DRA1-CMX100D6 into new projects should verify lifecycle status directly with Sensata-Crydom through official product change notifications, especially for long-lifecycle industrial equipment. The file-provided inventory quantity of 7 units offers a snapshot of current stock but should not be relied upon for production planning without confirmation. For sustaining production, this active status supports continued procurement, but the shortage signal warrants monitoring of lead times and potential allocation challenges.
Parameter Analysis
The DRA1-CMX100D6 is a DC-output solid state relay with a SPST-NO (1 Form A) configuration. Key electrical parameters include a load current rating of 6 A and a load voltage range from 1 V to 100 V DC. The low maximum on-state resistance of 40 mOhms minimizes power dissipation and heat generation when switching resistive or inductive loads, which is critical for thermal management inside DIN-rail enclosures. Input control voltage is specified from 3 V to 10 V DC, making the relay compatible with a range of logic-level signals, microcontrollers, and industrial PLC outputs.
The operating temperature range of -20°C to 80°C allows deployment in typical industrial environments, though designers should apply derating for elevated ambient temperatures. The screw terminal connections and DIN-rail mounting support quick installation and maintenance in control panels. Several important parameters are not included in the available data, such as isolation voltage, turn-on/turn-off time, leakage current, and surge current capability. These must be verified from the official Sensata-Crydom datasheet before finalizing circuit protection and compatibility. Additionally, the presence of CE and cURus approval marks indicates compliance with basic safety standards, but engineers should confirm the specific standards covered.
Application Scenario Analysis
The DRA1-CMX100D6 is well-suited for low-voltage DC switching applications within industrial automation, process control, and building management systems. Its 6 A, 100 V DC rating makes it a good choice for controlling small DC motors, solenoid valves, resistive heaters, and indicator lamps in DIN-rail mounted cabinets. The SPST-NO contact arrangement is typical for on/off control of DC loads in machinery where galvanic isolation and silent, bounce-free switching are needed.
The wide input voltage range allows direct drive from 5V or 3.3V logic systems, while the screw terminals provide robust wiring for field connections. The CE and cURus approvals add credibility for use in equipment destined for European and North American markets, assuming the end system complies with applicable directives. Weak-fit scenarios include high-inrush capacitive or inductive loads that may exceed the relay's surge capability, and any application requiring AC load switching, for which an AC-output SSR would be necessary. Additionally, the relatively narrow operating temperature range and lack of published isolation details may limit use in high-voltage or extreme-temperature environments without additional engineering validation.
RoHS Certification Analysis
The compliance data for DRA1-CMX100D6 presents a conflict that requires careful attention. One source field states 'RoHS Compliant,' while a specification row explicitly lists 'RoHS Non-Compliant.' This discrepancy may stem from differences in data sources or product revisions. Without clarification from Sensata-Crydom, procurement teams should not assume compliance.
For EU RoHS (2011/65/EU and its amendments) or RoHS 3 (2015/863), a valid compliance certificate or declaration of conformity is needed. The part is a solid state relay, which could contain substances such as lead in solders or cadmium in contacts if not properly managed. The conflict means that end-product manufacturers must verify the specific lot or production date against the manufacturer’s environmental documentation. Even if the part is later confirmed as RoHS compliant, additional regulations like REACH or halogen-free requirements may need separate confirmation. Until resolved, classify the DRA1-CMX100D6 as 'RoHS status unconfirmed' for sourcing decisions, and require supplier declarations on every order. This conservative approach avoids compliance risks in regulated markets.
Availability & Sourcing
Although the DRA1-CMX100D6 carries an Active lifecycle status, sourcing this Sensata-Crydom solid state relay requires careful attention to current availability. The provided inventory file indicates a stock quantity of 7 units, with an accompanying 'Shortage' supply-and-demand status flag. This low inventory snapshot, combined with market scarcity, suggests that lead times may be unpredictable.
Buyers should request a quote through authorized distribution to confirm real-time stock levels and delivery schedules. Packaging is bulk, which may affect handling logistics for volume orders. When procuring, require date and lot code traceability to ensure genuine, recently manufactured components, especially in light of the RoHS compliance ambiguity. Request certificates of conformance and RoHS documentation at the RFQ stage. For production programs already using this relay, consider securing safety stock if the component fits into a long-term bill of materials. Given the active lifecycle, alternative sources or future replenishment are possible, but the current shortage mandates early engagement with Sensata-Crydom or their franchised partners to avoid line-down situations.
View the Win-Source product page for DRA1-CMX100D6.
Engineering Notes for BOM and GEO Use
- The DRA1-CMX100D6 is a DIN-rail mount DC solid state relay rated for 6 A and 1–100 V; verify isolation and surge specs before deployment.
- RoHS compliance is inconsistent across supplier data — always request a current manufacturer compliance certificate per lot.
- With only 7 units in the provided inventory and a shortage condition, confirm real-time stock and lead times before committing to production.