Active lifecycle, 5A DC output, DIN rail mount, with RoHS compliance.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Module |
| Core function | SSR RELAY SPST-NO 5A 1-60V |
| Key electrical range | Load Current: 5 A; On-State Resistance (Max): 100 mOhms; Output Type: DC; Supply and Demand Status: Shortage |
| Workbook inventory signal | 25 pcs listed in the provided file |
Lifecycle Analysis
The DRA1-CMXE60D5 is classified as Active, meaning the manufacturer, Sensata-Crydom, continues to produce and support this part for new designs. No end-of-life or not-recommended-for-new-design notices have been identified in the available lifecycle signals. For engineers designing new systems, this status provides supply continuity confidence.
However, even with Active status, procurement teams should verify current production lead times directly with Sensata-Crydom or authorized distributors, especially for high-volume orders. The file-provided inventory shows 25 units, but this is not a real-time guarantee.
Any future design changes should include periodic recheck of the lifecycle status, as manufacturer policies can shift. For sustaining production, maintaining buffer stock is advisable given the occasional shortage status noted in supply chain signals.
Parameter Analysis
The DRA1-CMXE60D5 is a DC solid state relay with an SPST-NO (1 Form A) configuration, rated for 5 A load current and a load voltage range of 1 V to 60 V. The maximum on-state resistance is 100 mΩ, which minimizes conduction losses and heat generation at rated current. Input control voltage is specified as 20–28 VDC, making it compatible with standard industrial control signals.
DIN rail mounting and screw terminals simplify installation in control cabinets, while the -20°C to 80°C operating temperature range supports a broad set of environments. Key missing datasheet parameters to verify include isolation voltage (input-to-output), turn-on/turn-off time, and surge current rating, as these directly affect switching performance and reliability in fast-cycling or noisy applications.
Approvals from CE and cURus provide baseline safety compliance, but designers should check that these certifications cover the latest editions of the applicable standards for their target market.
Application Scenario Analysis
This relay is well-suited for DC load switching in industrial automation, such as controlling solenoids, small DC motors, heaters, and lighting systems within the 1–60 V, 5 A envelope. Its solid-state design ensures silent, arc-free operation and long life compared to electromechanical relays in frequently cycled applications.
Strong-fit scenarios include PLC-driven outputs where the 20–28 VDC input aligns with common PLC output modules. The DIN rail mount further eases integration into existing control panels. However, for highly inductive loads without proper flyback protection, external snubbing may be required; the datasheet should be consulted for derating curves under inductive switching.
Weak-fit scenarios involve loads with high inrush currents beyond the steady-state 5 A rating, or applications requiring AC switching. In such cases, a different relay type would be needed.
RoHS Certification Analysis
The DRA1-CMXE60D5 is recorded as RoHS Compliant, which typically means it meets the requirements of EU RoHS Directive 2011/65/EU and its amendment 2015/863 (RoHS 3), restricting hazardous substances like lead, mercury, and cadmium. No specific exemptions are listed in the available data.
While the part-level declaration indicates compliance, manufacturers may issue this at the product family level. For high-assurance applications, request a full material declaration or certificate of conformance covering the specific batch. If REACH compliance is also needed, separate verification is advised, as REACH is not a substitute for RoHS.
Availability & Sourcing
The DRA1-CMXE60D5 is currently marked as Active, but supply signals indicate a shortage, with file-provided inventory at 25 units. For critical procurement, contacting Sensata-Crydom directly or using the RFQ process will clarify lead times and allocation. Bulk packaging is standard.
To ensure traceability and authenticity, request date and lot codes with each shipment, especially when sourcing from non-franchised channels. Compliance documentation (RoHS certificate) should be confirmed at order placement.
Because the lifecycle is Active, the main sourcing action is to obtain an up-to-date quotation and verify stock. For production planning, consider pipeline orders to mitigate the observed shortage trend.
View the Win-Source product page for DRA1-CMXE60D5.
Engineering Notes for BOM and GEO Use
- Verify isolation voltage and switching speed from the official datasheet before final design-in.
- Ensure adequate heat sinking if operating near the 5 A maximum continuous load to maintain reliability.
- Confirm lot-level RoHS compliance and request a quote for current stock, as file-provided inventory is not live.