SPST-NO, 5A, 12-280V, DIN Rail Mount, AC Zero-Cross Solid State Relay
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Module |
| Core function | SSR RELAY SPST-NO 5A 12-280V |
| Key electrical range | Load Current: 5 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Temperature Range - Operating: -20°C ~ 80°C |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The part DRA1-CX240D5 is currently listed as Active in the manufacturer lifecycle status, indicating it is in full production and available for new designs and ongoing procurement. An Active status generally provides confidence for new product introductions and long-term sourcing, but it is always prudent to revalidate lifecycle status directly with Sensata-Crydom for programs with extended lifetimes or high regulatory requirements.
The available data shows no conflicting lifecycle signals across available sources, and the part is classified with a low risk level. This alignment supports standard procurement processes without immediate obsolescence concerns.
However, the workbook indicates a limited inventory quantity of 13 units, and the supply and demand status is noted as Shortage. While this snapshot is file-provided and not real-time, it suggests that buyers should confirm current stock availability and lead times before making purchase decisions. For critical applications, consider securing safety stock or establishing second-source agreements to mitigate supply disruption risks.
Parameter Analysis
The DRA1-CX240D5 is a solid state relay featuring an SPST-NO (1 Form A) contact configuration with an AC zero-crossing output. Key electrical specifications include a load voltage range of 12 V to 280 V AC and a maximum load current of 5 A. The input control voltage is specified as 3 to 15 VDC, making it compatible with common logic-level signals and industrial PLC outputs.
The zero-cross detection ensures that load switching occurs at the zero-voltage point of the AC waveform, which minimizes inrush currents and electromagnetic interference. This characteristic is particularly beneficial for resistive loads such as heaters and incandescent lamps. The DIN rail mount and screw terminals facilitate quick installation in industrial control panels, and the operating temperature range of -20°C to 80°C suits most indoor environments.
Noteworthy missing parameters from the available data include off-state leakage current, isolation voltage rating, peak surge current, and operational timing specifications. Engineers should consult the full Sensata-Crydom datasheet to verify these values for proper derating, safe isolation, and coordination with circuit protection devices. Additionally, confirm the exact derating curve for elevated temperatures to avoid thermal overstress.
Application Scenario Analysis
Given its specifications, the DRA1-CX240D5 is ideally suited for switching low-to-medium power AC resistive loads in industrial automation and process control systems. Typical strong-fit applications include electric heater control, resistive load banks, lighting circuits, and small single-phase motors where frequent on/off cycling is required. The DIN rail form factor and screw terminals align with panel-mount installations in machinery and cabinet systems.
The zero-cross output type ensures low EMI and reduced switch-on stress for resistive loads, but may limit its performance with highly inductive or capacitive loads that cause significant phase shifts. While the relay can handle moderate inductive loads with appropriate snubbing, it may not be the best choice for high-inrush motor starts without derating. The DC input control range of 3-15 VDC allows direct interfacing with microcontrollers, PLCs, and distributed I/O modules, making the relay suitable for IoT-enabled control systems.
For applications requiring high switching frequency or phase-angle control, this device may not be appropriate, as zero-cross switching is synchronized to the line frequency and not designed for fast cycling or proportional control. Verify with the manufacturer if enhanced surge capability or output snubbers are integrated for your specific load type.
RoHS Certification Analysis
The DRA1-CX240D5 is designated as RoHS Compliant according to the provided data. This indicates that the part meets the European Union's Restriction of Hazardous Substances (RoHS) directive, which restricts the use of lead, mercury, cadmium, hexavalent chromium, and specific flame retardants. The compliance status suggests that the component is suitable for markets requiring RoHS adherence, including the EU and many global regions that align with these standards.
Unless otherwise stated, compliance is typically assessed at the component level and may apply to the current revision of the directive, such as RoHS 3 (EU 2015/863). However, the data does not specify the exact RoHS revision or provide a certificate number. For formal compliance documentation, request a manufacturer certificate or test report from Sensata-Crydom, especially if your product must meet additional requirements such as REACH, halogen-free, or MSL classifications.
It is also important to recognize that RoHS compliance is often declared at the product family level, and subsequent lot-level changes require re-certification. Therefore, for high-volume production, verify the compliance documentation for the specific date codes you intend to purchase.
Availability & Sourcing
The DRA1-CX240D5 solid state relay is available through global distribution channels, though the current supply and demand status is noted as Shortage. A file-provided workbook indicates a limited on-hand quantity of 13 units, but this is not a live inventory figure and does not guarantee immediate availability. Engineers and buyers should engage with authorized distributors to confirm current stock, lead times, and allocation status before placing orders.
Given the Active lifecycle and potential constraints, it is recommended to submit a request for quotation (RFQ) to obtain real-time pricing and delivery information. When sourcing, verify packaging type (Tube), authenticity through manufacturer traceability, and request certificates of conformance that include RoHS compliance and date/lot code traceability.
For sustaining production, consider placing scheduled orders to secure supply, especially if the component is designated as a shortage item. If the DRA1-CX240D5 is intended for a new design, validate the lifecycle status with the manufacturer and assess lead-time risks to prevent production delays. For NRND or EOL scenarios, the approach would shift to securing last-time buys or evaluating migration paths, but based on current data, Active status encourages confident procurement with standard qualification protocols.
View the Win-Source product page for DRA1-CX240D5.
Engineering Notes for BOM and GEO Use
- Validate that the 5 A load rating is sufficient under worst-case ambient temperature and load type; consult the derating curve in the full datasheet.
- Check zero-cross switching timing to ensure compatibility with load inrush requirements and overall system EMC performance.
- Secure inventory confirmation and compliance documentation before committing to high-volume production, given the noted shortage.