Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategorySolid State Relays
PackageModule
Core functionSSR RELAY SPST-NO 5A 12-280V
Key electrical rangeLoad Current: 5 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Temperature Range - Operating: -20°C ~ 80°C
Workbook inventory signal9 pcs listed in the provided file

Lifecycle Analysis

The DRA1-MCXE240D5 is classified as Active per Sensata-Crydom’s lifecycle documentation, and all available signals consistently indicate a low-risk procurement status. For new designs, this means the part is in full production with manufacturer support expected to continue. However, the supplied inventory status indicates a shortage condition, so planners should factor in potential lead time variability. The file-provided quantity of 9 units is not guaranteed real-time; always request a quote to confirm current stock and delivery dates.

For sustaining production, the Active lifecycle supports ongoing purchases without immediate migration planning. Nevertheless, verify with Sensata-Crydom or authorized distributors that no NRND or EOL notices are pending, especially if the part is being designed into long-lifecycle equipment. Periodic rechecks of manufacturer PCNs are recommended, as relay product lines can shift due to component obsolescence or factory transfers.

Given the shortage signal, conservative procurement should include safety stock and contractual lead-time commitments. If sourcing through non-franchised channels, ensure traceability and authenticity checks to avoid counterfeit or re-marked devices.

Parameter Analysis

The DRA1-MCXE240D5 is a DIN rail mount AC solid state relay with SPST-NO configuration and zero-cross switching. Key parameters for integration include the load voltage range of 12 to 280 VAC, load current rating of 5 A, and control input voltage of 15 to 32 VDC. These values define the operational envelope: the relay can switch resistive or inductive AC loads up to 5 A, but derating is advised for high inrush currents or elevated ambient temperatures beyond 25°C. The -20°C to 80°C operating temperature range allows deployment in industrial control panels, but close attention must be paid to derating curves from the manufacturer’s datasheet to ensure reliable performance at extremes.

The zero-cross output type minimizes EMI and inrush current by turning on when the AC voltage is near zero, making it suitable for resistive loads like heaters and incandescent lamps, as well as some inductive loads with power factor correction. The screw terminal connection and module packaging simplify field wiring and DIN rail installation, reducing assembly time. However, several parameters missing from the provided data—such as isolation voltage, maximum surge current, off-state leakage, and on-state voltage drop—must be verified before finalizing a design. These affect safety margin, snubber requirements, and thermal dissipation calculations.

To avoid integration issues, procure a full datasheet and confirm input current draw to ensure compatibility with your driver circuit, ideally leaving a 20% margin. Also validate the CE and cURus approvals against your target regulatory requirements, particularly if deploying in safety-critical zones. The solid-state design implies no mechanical wear, but protection circuitry (varistor or TVS) is recommended for inductive kickback.

Application Scenario Analysis

The DRA1-MCXE240D5 fits firmly into industrial automation applications where DIN rail mounting and DC control of AC loads are standard. Typical strong-fit scenarios include PLC-controlled switching of solenoid valves, small motors (fractional HP), heater elements, and indicator lamps within automated machinery. The zero-cross switching reduces electrical noise, which is advantageous in EMI-sensitive environments such as laboratory instruments or medical device controls where uninterrupted reliability is required. Its 5 A rating can handle most control-level loads directly, eliminating external contactors for loads under 1.2 kW at 240 VAC.

Weak-fit scenarios include high inrush applications like switching capacitive loads or large transformer primaries without additional inrush limiting, as the zero-cross feature may actually increase surge stress at turn-on. Similarly, DC load switching is not supported, so it cannot replace DC-output SSRs in battery management or photovoltaic systems. For high-speed cycling above a few hertz, the zero-cross design might introduce delays unsuitable for precise timing. Engineers should also consider that the DRA1-MCXE240D5’s solid-state nature provides silent operation and long life in benign conditions, but it may still require a heat sink if ambient temperatures approach the 80°C maximum while carrying near-rated current continuously.

Designers evaluating this relay for safety circuits must independently assess whether the SPST-NO configuration meets the required redundancy level, as a single relay cannot provide fail-safe operation in critical e-stop circuits without additional external monitoring. The CE and cURus approvals support use in North American and European markets, but panel build regulations may require supplementary fusing or isolation coordination per IEC 60947.

RoHS Certification Analysis

The DRA1-MCXE240D5 is designated RoHS Compliant based on supplier data, indicating compliance with Directive 2011/65/EU and amendment 2015/863 restricting hazardous substances such as lead, mercury, cadmium, and certain flame retardants. This status generally allows free circulation within EU markets and supports WEEE compliance requirements. However, the provided information does not include a specific RoHS certificate number or test report, so for high-compliance manufacturing, request the manufacturer’s Declaration of Conformity (DoC) to confirm lot-level adherence, particularly if your purchasing covers multiple date codes.

While RoHS compliance is stated, no data is supplied regarding REACH (EC 1907/2006), halogen-free status, or moisture sensitivity level (MSL). REACH compliance is a separate regulatory obligation, and engineers should note that RoHS conformance does not automatically satisfy REACH SVHC restrictions. If your product must meet aerospace or military standards, consider that additional substance restrictions may apply beyond RoHS. When sourcing through secondary markets, request batch-specific XRF test reports to guard against non-compliant inventory, especially for older production lots that may have been manufactured before stricter enforcement.

For documentation purposes, integrate the DRA1-MCXE240D5 into your technical file with a copy of the supplier’s RoHS statement. In the absence of explicit exemption details, assume standard exemptions for lead in solders (e.g., high-reliability applications) may apply, but verify with Sensata-Crydom. This relay does not typically require exemptions due to its solid-state design, but confirmation ensures uninterrupted import and export compliance.

Availability & Sourcing

The DRA1-MCXE240D5 is an Active part from Sensata-Crydom, and the file-provided quantity shows 9 units available. However, this is a snapshot figure, not a guaranteed real-time inventory level, and a shortage status is flagged. For current availability, always request a live quote from authorized distributors or franchised sources. Emphasize date and lot code traceability, particularly if the relay will be used in regulated industries like medical or aviation, where component provenance is audited.

Given the shortage signal, buyers should compare lead times across multiple channels and consider securing inventory now if the part is sole-sourced. The relay ships in bulk packaging, so confirm that the quantity and packaging format meet your assembly requirements. Requesting sample lots for verification is advisable before committing to volume purchases. In parallel, evaluate whether Sensata-Crydom offers a pin-compatible upgraded series or if the DRA1-MCXE240D5 is a legacy product being phased out—though lifecycle says Active, independent confirmation protects against surprise discontinuations.

To streamline procurement, include the complete part number, manufacturer, and requested certifications (RoHS, CoC) in your RFQ. For long-term supply assurance, negotiate stocking agreements or schedule blanket orders with periodic releases. Because this is a specialized SSR with DIN rail mounting, third-party clones are unlikely, but verify any non-authorized source’s authenticity through physical inspection and function testing. As with all semiconductor-based relays, ESD precautions during handling and storage are critical to maintaining reliability.

View the Win-Source product page for DRA1-MCXE240D5.

Engineering Notes for BOM and GEO Use

  • Verify input control voltage limits (15–32 VDC) and load derating at elevated temperatures; missing datasheet specs like surge current and isolation voltage must be obtained from Sensata-Crydom.
  • The zero-cross switching reduces EMI but may increase inrush in capacitive loads; add external snubber or inrush limiter for non-resistive loads beyond 5 A rating.
  • Despite RoHS compliance, secure a manufacturer's DoC and consider REACH requirements if EU market entry is planned, especially for high-compliance assemblies.