330 µH Shielded Wirewound Inductor, AEC-Q200, Surface Mount
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | Fixed Inductors |
| Package | Nonstandard |
| Core function | FIXED IND 330UH 690MA 892 MOHM |
| Key electrical range | Current - Saturation (Isat): 1.092A; Current Rating (Amps): 690 mA; DC Resistance (DCR): 892mOhm; Inductance Frequency - Test: 100 kHz |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Eaton Bussmann DRA124-331-R is marked Active, with all lifecycle signals aligned. This status indicates the part is in full production and supported for new designs. The AEC-Q200 rating further suggests a qualified, robust product suitable for automotive and industrial applications where long-term availability is essential.
However, the supply and demand snapshot shows a 'Shortage' status. This file-provided indicator may not reflect real-time market conditions, but it warrants caution. Designers should verify lead times and stock with authorized distributors before committing the DRA124-331-R to high-volume production.
Despite the shortage flag, the Active lifecycle with no NRND or EOL signals means the component is a safe choice for new development, provided procurement can secure adequate supply. Regular revalidation of lifecycle status is recommended for long-running programs.
Parameter Analysis
Key parameters for the DRA124-331-R include a 330 µH inductance with ±20% tolerance, tested at 100 kHz. This inductance value is typical for energy storage in switch-mode power supplies and DC-DC converters. The tolerance affects filtering accuracy and should be accounted for in feedback loop design.
The rated current is 690 mA, while the saturation current (Isat) is 1.092 A. The margin between rated and saturation current allows some headroom for peak currents, but prolonged operation near saturation can lead to inductance drop and increased ripple. DC resistance is 892 mΩ, which directly impacts I²R losses and must be managed thermally, especially in high-temperature environments up to 165°C. The shielded construction helps control EMI.
Important missing parameters include Q factor, self-resonant frequency, and core loss data. Engineers should obtain the full datasheet from Eaton to verify these before finalizing magnetics design. However, the provided specifications and AEC-Q200 qualification give a solid baseline for component evaluation.
Application Scenario Analysis
The DRA124-331-R is well-suited for automotive electronic modules such as engine control units, body electronics, and LED lighting drivers, thanks to its AEC-Q200 qualification and wide temperature range. In industrial settings, it fits motor drives, power inverters, and automation controllers that demand high reliability.
Its shielded, surface-mount package is ideal for noise-sensitive designs where electromagnetic interference must be minimized. The 12.5 mm square footprint is moderately large; not optimal for ultra-compact portable devices but acceptable for many board-level applications.
The component is less suitable for high-frequency RF matching networks or oscillators, as indicated by the lack of Q and SRF data and the inherent characteristics of wirewound construction. Without specific high-frequency parameters, performance above a few MHz should be verified experimentally.
RoHS Certification Analysis
Eaton Bussmann declares the DRA124-331-R as RoHS Compliant. This typically certifies conformance to EU RoHS Directive 2011/65/EU, including the 2015/863 amendment (RoHS 3), restricting lead, mercury, cadmium, and other hazardous substances below threshold limits. No exemptions are noted in the provided data, implying full compliance.
It is important to note that this declaration is at the component level. System-level compliance depends on the entire assembly, so OEMs must complete their own RoHS assessment. For formal qualification, request a certificate of compliance or full material declaration from the supplier.
REACH status, halogen content, and MSL (moisture sensitivity level) are not specified here. If these are relevant to your product, obtain the necessary documentation from Eaton or your distributor. The RoHS compliance alone does not guarantee REACH SVHC absence.
Availability & Sourcing
The DRA124-331-R is an Active production part from Eaton Bussmann, supplied in tape & reel packaging for automated assembly. The file-based inventory shows a workbook quantity of 1 unit, but this is not a real-time stock check and should not be relied upon for purchasing decisions.
Given the indicated 'Shortage' status, it is crucial to request a quote to verify current availability, lead times, and order multiples. Work with authorized distributors or directly with Eaton to secure supply, especially if planning high-volume production. Consider requesting traceability documentation including date/lot codes to ensure consistent quality.
For new designs, the Active lifecycle supports standard procurement with compliance verification. However, to mitigate risk, engineers may evaluate alternative parts or maintain safety stock of the DRA124-331-R until supply stabilizes. Always confirm lifecycle status at time of order to avoid surprises.
View the Win-Source product page for DRA124-331-R.
Engineering Notes for BOM and GEO Use
- Verify DC resistance and current ratings against your application’s thermal and derating requirements, particularly when operating near the 165°C upper limit.
- Confirm inductance tolerance and saturation current margin in your converter design; note the ±20% tolerance and 1.092 A saturation current provide headroom above the 690 mA rated current.
- Due to the indicated shortage, secure supply early and request a quote for lead times; consider second-source alternatives if long-term availability is critical.