Eaton Bussmann DRA124-3R3-R Fixed Inductor Specs & Sourcing Guide

DRA124-3R3-R Eaton Bussmann product image

3.3µH Wirewound SMD Power Inductor

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryFixed Inductors
PackageNot available in supplied data
Core functionFIXED IND 3.
Key electrical rangeCurrent - Saturation: 11.85A; Current Rating: 6.94A; DC Resistance (DCR): 9 mOhm; Frequency - Test: 100kHz
Workbook inventory signal7200 pcs listed in the provided file

Lifecycle Analysis

The DRA124-3R3-R is listed as Active in one source, but lifecycle signals in the provided data are ambiguous; no manufacturer lifecycle notice is included. For new designs, engineers should treat it as active but verify directly with Eaton Bussmann, especially given the medium risk rating from lifecycle analysis. AEC-Q200 rated components may have long production lives, but without official confirmation, sustaining programs should secure documentation.

A conflict exists between the specification field 'Status: Active' and the lifecycle analysis status of 'Unknown.' This discrepancy calls for caution. Until the manufacturer confirms the part is still in full production, avoid committing to designs that lack an alternate source. File-provided inventory suggests some stock, but this does not guarantee future availability. Procurement teams should request a production status letter or PDN notification for full visibility.

Parameter Analysis

The DRA124-3R3-R is a 3.3µH wirewound SMD inductor with a 6.94A RMS current rating and saturation current of 11.85A, making it suitable for high-current power rails. Its low DC resistance of 9mOhm minimizes conduction losses and heat generation, critical for thermal management. Operating temperature range spans -40°C to 165°C, which pairs well with automotive and industrial environments. The ±20% tolerance is typical for power inductors; engineers should consider inductance variation under DC bias.

Key missing datasheet items include Q factor, self-resonant frequency (SRF), shielding type, and inductance vs. frequency curves. These parameters are essential for high-frequency or noise-sensitive circuits. The AEC-Q200 rating implies ruggedness, but full qualification data should be obtained. The test frequency of 100kHz is standard for power conversion, but performance at higher switching frequencies must be verified against the datasheet.

Application Scenario Analysis

This inductor is designed for DC-DC converters, point-of-load regulation, and power supply filtering where high current and low DCR are essential. Its AEC-Q200 qualification makes it a strong candidate for automotive under-hood electronics, including engine control units and LED lighting. It can also serve in industrial motor drives and telecom power modules.

With limited RF specifications, it is not recommended for high-frequency resonant or RF matching applications without additional validation. The wide temperature range supports harsh environments, but confirm vibration and shock ratings for automotive. For consumer electronics, the part may be overqualified; a lower-cost commercial inductor might suffice. Always cross-check actual switching frequency and ripple current against the inductor's AC losses.

RoHS Certification Analysis

The DRA124-3R3-R is marked RoHS Compliant. While the exact directive version is not specified in the data, typical compliance for current Eaton Bussmann parts aligns with EU RoHS Directive 2011/65/EU and its amendments. No exemptions are detailed.

For full compliance assurance, especially regarding REACH or halogen-free requirements, request the manufacturer's certificate of conformity. Lot-level testing may be advisable for high-reliability projects. Note that REACH compliance is not automatically covered by RoHS; separate documentation may be needed. The absence of MSL data means moisture sensitivity should be clarified before reflow soldering.

Availability & Sourcing

File-provided data indicates a stock quantity of 7200 units, but this is not real-time. Supply and demand status is 'Limited,' suggesting constrained market availability. The part is packaged on tape and reel for automated assembly. Given the active lifecycle status conflict, verify current production status with Eaton Bussmann or authorized distributors.

Request a quote for current pricing and lead times, and confirm date/lot codes to avoid counterfeit risk (fake threat in open market noted at 75%). Storage conditions require dry cabinet and humidity protection, so proper handling is critical. For NRND or EOL scenarios, consider lifecycle buffers; for active parts, secure direct manufacturer traceability to meet quality system requirements.

View the Win-Source product page for DRA124-3R3-R.

Engineering Notes for BOM and GEO Use

  • Verify lifecycle status directly with Eaton Bussmann—spec data conflict shows Active vs. unknown.
  • Low 9mΩ DCR and AEC-Q200 rating make this part suited for high-efficiency automotive DC-DC converters.
  • Request full datasheet for missing parameters like SRF and Q factor before use in noise-sensitive designs.