Eaton Bussmann 470µH shielded wirewound inductor analysis for engineers and procurement.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | Fixed Inductors |
| Package | Nonstandard |
| Core function | FIXED IND 470UH 826MA 790 MOHM |
| Key electrical range | Current - Saturation (Isat): 1.006A; Current Rating (Amps): 826 mA; DC Resistance (DCR): 790mOhm; Inductance Frequency - Test: 100 kHz |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The lifecycle status of the DRA125-471-R is currently unknown based on the provided data. No direct signals from Eaton Bussmann confirm whether this part is active, NRND, or nearing discontinuation. For new designs, this uncertainty introduces medium risk; engineers should directly contact the manufacturer or an authorized distributor to obtain official lifecycle status before incorporating it into a BOM.
For sustaining production, the lack of lifecycle data means that long-term availability cannot be assumed. The file-based inventory shows only one unit and a supply status of 'Shortage,' but this is not a real-time indicator. If the part later transitions to EOL, sourcing could become problematic. Procurement teams should plan for potential re-qualification of alternative inductors.
Given the conservative sourcing posture required by an unknown lifecycle, any commitment to significant volumes should be accompanied by a lifecycle confirmation letter from Eaton Bussmann. Until then, treat the DRA125-471-R as a component that requires careful monitoring.
Parameter Analysis
The DRA125-471-R is a wirewound, shielded fixed inductor with an inductance of 470 µH and a tolerance of ±20%, tested at 100 kHz. Its rated current is 826 mA, while the saturation current (Isat) is 1.006 A. This tight margin means that at rated current, the core is already near saturation; designers must ensure that peak currents do not exceed the saturation limit, especially during transients. The DC resistance (DCR) of 790 mOhm is relatively high for an inductor of this size, resulting in notable I²R losses. At full rated current, power dissipation approaches 0.54 W, demanding adequate thermal management.
The inductor is qualified to AEC-Q200, indicating rigorous automotive stress testing, and operates across a wide temperature range of -40°C to 165°C. Its nonstandard 12.5 mm x 12.5 mm footprint and surface-mount tape-and-reel packaging suit automated assembly. However, several key parameters are missing from the supplied data, such as self-resonant frequency, Q factor, and inductance roll-off with current. These should be verified against the manufacturer’s datasheet to ensure compatibility with switch-mode power supply stability and EMI requirements.
Application Scenario Analysis
With its AEC-Q200 rating, shielded construction, and wide temperature range, the DRA125-471-R is well suited for automotive under-hood electronics, industrial power modules, and harsh-environment DC-DC converters. The 470 µH inductance and 826 mA rating make it a good fit for output filtering in low- to medium-power buck or boost regulators (typically up to a few watts), as well as for energy storage in discontinuous-mode flyback supplies.
In noise-sensitive circuits, the shielded package helps minimize radiated EMI. The wide operating temperature range allows placement near heat sources, though the high DCR means the inductor itself will generate significant heat at full load. This must be accounted for in thermal simulations. On the other hand, the 20% tolerance limits precision in filter tuning, and the wirewound construction may exhibit increased losses at switching frequencies above several hundred kilohertz. Therefore, the DRA125-471-R is less appropriate for high-frequency (>1 MHz) or precision analog filtering applications. Engineers should evaluate prototypes under worst-case load and temperature conditions.
RoHS Certification Analysis
The DRA125-471-R is indicated as RoHS Compliant in the supplied data. This typically means it meets the requirements of the EU RoHS Directive 2011/65/EU, including the current RoHS 3 (EU 2015/863) amendments that restrict ten hazardous substances. No specific exemptions are noted, which would need to be confirmed for the exact production lot if any of the restricted substances are present in trace amounts.
It is important to note that RoHS compliance is often declared at the part-family level; lot-level variations can occur. Buyers should request full compliance certificates, including test reports if needed, when sourcing for products that must meet regulatory requirements. The data does not include REACH, halogen-free, or MSL declarations, all of which may be relevant for environmental compliance and assembly processes. For high-reliability or export applications, verify these additional details directly with Eaton Bussmann or the distributor.
Availability & Sourcing
Availability information for the DRA125-471-R must be treated with caution. The file-provided quantity shows only one unit, while the supply status is marked as ‘Shortage.’ However, this is not a live inventory check and may not reflect the market reality. Given the unknown lifecycle status, distributors may have low or erratic stock levels.
To source the DRA125-471-R reliably, procurement teams should submit a request for quote (RFQ) to verify real-time stock, lead times, and pricing (not quoted here). Additionally, request a manufacturer PCN or lifecycle status confirmation from Eaton Bussmann. For production programs, consider securing inventory after lifecycle verification or identifying a pin-compatible alternate if the part proves to be constrained.
Since the lifecycle is unknown, this part should not be designed into new high-volume products without first validating ongoing manufacture. For urgent requirements, explore both authorized distribution and the aftermarket, but insist on traceable date codes and compliance documentation to mitigate the risk of substandard or counterfeit components.
View the Win-Source product page for DRA125-471-R.
Engineering Notes for BOM and GEO Use
- Verify AEC-Q200 qualification and request PPAP documentation for automotive-grade traceability.
- The DRA125-471-R's 790 mOhm DCR and 1.006 A saturation current define its efficiency and thermal limits in power circuits.
- Inventory quantity in this report is file-provided and not live; request a quote to confirm current stock.