Active lifecycle, 480V 5A 3PST-NO, chassis/DIN rail mount, RoHS compliant
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Contactors (Solid State) |
| Package | Module |
| Core function | 480V 5A 120VAC NO AUX RN 3L |
| Key electrical range | Load Current: 5 A; Output Type: AC; Supply and Demand Status: Shortage; Voltage - Input: 90 ~ 140VAC |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The Sensata-Crydom DRC3P48B400R is classified as Active with low risk, based on available lifecycle parameters. This status indicates the part is in full production and supported by the manufacturer, making it a safe choice for new designs as well as existing production lines. No lifecycle conflicts exist in the supplied data.
Engineers should still request the latest product change notification (PCN) or lifecycle documentation from Sensata-Crydom when qualifying the DRC3P48B400R for mission-critical applications. While the active status suggests long-term availability, supply chain dynamics can shift, so periodic revalidation is recommended.
A file-provided inventory quantity of 13 units was noted, but this figure is not a real-time guarantee. For current stock, always request a quote and verify lead times directly with the distributor.
Parameter Analysis
Key specifications for the DRC3P48B400R include a load current of 5 A and a wide load voltage range of 48–530 V AC, which define the contactor’s power handling capability. The 3PST-NO (3 Form A) circuit configuration indicates three normally-open poles, suitable for three-phase AC switching. Control input voltage is 90–140 VAC, important for matching to existing control transformer outputs.
The module package and screw terminal termination style simplify integration into industrial panels, while chassis and DIN rail mounting options offer flexibility. The bulk packaging suggests the part is typically ordered in production quantities, not tape-and-reel.
Several critical parameters are not provided in the current dataset: thermal resistance, response time, isolation voltage, and surge current rating. Designers should consult the official Sensata-Crydom datasheet to verify these values for thermal management, electrical safety margins, and load compatibility. Without them, worst-case assumptions must be applied in design.
Application Scenario Analysis
The DRC3P48B400R fits well in industrial control systems requiring silent, fast switching of AC loads up to 5 A. Typical strong-fit applications include resistive heating elements, lighting control, and small three-phase motor starters operating within the voltage range. Its solid-state design eliminates contact wear, making it suitable for high-cycle applications.
Weak-fit scenarios involve high inrush capacitive loads or DC switching, as the output type is AC and the datasheet silent on maximum surge capability. Similarly, environments with extreme temperature swings may require additional derating curves not yet available. Always confirm the load characteristics against manufacturer recommendations.
For upgrade or replacement, ensure the replacement solid-state contactor matches the control voltage range and form factor, as the DRC3P48B400R’s module package and screw terminals are common but not universal.
RoHS Certification Analysis
The DRC3P48B400R is listed as RoHS Compliant, meeting EU RoHS directive requirements for hazardous substance restrictions. This compliance is typically at the product family level; however, for high-reliability applications, obtaining a lot-specific RoHS certificate from Sensata-Crydom is advisable.
No REACH or halogen-free declarations are included in the supplied data. If these additional regulatory requirements are needed, request the relevant documentation from the manufacturer. RoHS compliance alone does not automatically confirm REACH SVHC status or low-halogen content.
For procurement, RoHS compliance reduces end-of-life recycling burdens and meets import requirements for many regions. Verify the part’s compliance status against your specific regulatory dossier before placing large orders.
Availability & Sourcing
The DRC3P48B400R is an active part, and sourcing should follow a standard request-for-quote (RFQ) process. Buyers should specify acceptable date/lot codes, packaging preference (bulk), and any required compliance documentation. The file indicates a limited stock quantity of 13 units, but this is not a live inventory figure; actual availability may differ.
Given the noted supply shortage status, lead time confirmation is critical. Engage with authorized distributors early to secure allocation for production runs. For engineering samples, verify that the provided units carry full manufacturer warranty and traceability.
Since the DRC3P48B400R is active, the primary action is to request a quote with lifecycle verification and expected delivery dates. For large volumes, consider negotiating a scheduled order agreement to mitigate intermittent shortages.
View the Win-Source product page for DRC3P48B400R.
Engineering Notes for BOM and GEO Use
- Verify control voltage compatibility: input range 90-140VAC; ensure stable supply for reliable switching.
- Consider derating for inductive loads; load voltage peaks up to 530V require proper snubbing for transient protection.
- Confirm mounting method: chassis or DIN rail; use screw terminals with appropriate torque specs from datasheet.