Active solid state contactor, 7.6A load, 48-530VAC, 90-140VAC input, zero cross switching, screw terminals, chassis/DIN mount.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Contactors (Solid State) |
| Package | Module |
| Core function | 480V 7. |
| Key electrical range | Load Current: 7.6 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Voltage - Input: 90 ~ 140VAC |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Sensata-Crydom DRC3P48B4202 solid state contactor is currently listed as Active. Active lifecycle status confirms that the part is in full production and supported for new designs as well as ongoing maintenance. There are no conflicting signals; all available indicators align as Active.
Despite the Active status, supply and demand data indicates a shortage condition, which may impact immediate availability. The file-provided inventory shows limited quantities, but these are not guaranteed real-time. For new designs, the DRC3P48B4202 remains a viable choice, but procurement teams should engage with authorized distribution early to secure production volumes.
For sustaining production, consider monitoring manufacturer product change notices and maintaining safety stock levels. The low lifecycle risk suggests that the part will remain available for the foreseeable future, but external supply dynamics may still affect lead times.
Parameter Analysis
The DRC3P48B4202 is specified as a 3PST-NO (3 Form A) solid state contactor with a load current rating of 7.6 A and a load voltage range of 48 to 530 VAC. The input control voltage is 90–140 VAC, making it compatible with standard industrial control circuits. The zero-cross output type ensures switching near the zero-voltage point of the AC waveform, reducing inrush and electromagnetic interference.
Mounting options include chassis and DIN rail, and termination is via screw terminals, simplifying panel integration and field wiring. The module package likely contains a complete SSR assembly with internal snubber and protection, but verification in the datasheet is recommended. The description also mentions "2NO," which differs from the 3PST-NO spec; the exact contact configuration should be confirmed from official documentation to avoid design errors.
Critical missing parameters include isolation voltage, operating temperature range, and overtemperature protection features. Engineers should request the full datasheet to evaluate thermal derating curves and ensure the contactor meets safety spacing requirements for the intended application.
Application Scenario Analysis
The DRC3P48B4202 solid state contactor is well suited for resistive AC load switching in industrial automation. Typical applications include controlling electric heaters, lighting banks, and small motors where frequent cycling, silent operation, and long mechanical life are required. The zero-cross switching characteristic makes it ideal for resistive loads, as it minimizes inrush current and extends element life.
It is less suitable for highly inductive loads such as large transformers or contactor coils without appropriate snubbing, as zero-cross switching can cause high di/dt stress. Phase-angle control applications are not supported. Additionally, loads exceeding the 7.6 A continuous rating or requiring DC switching are beyond the device’s capability. The flexible mounting and screw terminal connection suit distributed control panels and retrofits.
When evaluating the DRC3P48B4202 for a project, verify that the ambient temperature and enclosure ventilation allow operation within the derated current limits. Check that the input voltage range matches the control system and that the load voltage does not exceed 530 VAC under worst-case conditions.
RoHS Certification Analysis
The DRC3P48B4202 is listed as RoHS Compliant, indicating that it meets the substance restrictions of the EU RoHS directive. While the exact directive revision is not specified, current compliance likely covers RoHS 3 (EU 2015/863), which includes additional phthalates. However, a manufacturer's certificate of compliance should be obtained for formal documentation.
No exemptions are noted, suggesting a straightforward compliance profile. REACH status is not provided in the available data; if REACH compliance is required, request a separate statement from Sensata-Crydom. Halogen-free and MSL data are not applicable or not provided for this module-type product.
For design qualification, ensure that the RoHS status is verified at the lot level for production units, as family-level compliance may not guarantee every batch. This is particularly important when the procurement channel includes non-franchised distributors.
Availability & Sourcing
The DRC3P48B4202 is an Active part with a low lifecycle risk, but current supply signals indicate a shortage. File-provided inventory quantities, such as 1 unit in one list or 6 in another, should be treated as indicative snapshots and not real-time availability. To source this contactor, request a quote from authorized Sensata-Crydom distributors, specifying the part number and preferred packaging (bulk).
Due to the Active lifecycle, standard procurement workflows apply: confirm lead times, request date/lot code traceability, and verify RoHS compliance documentation before finalizing the order. For volume production, engaging with the manufacturer’s field sales team can help secure allocation and receive early warning of any lifecycle changes.
If the shortage persists, consider evaluating alternative packaging options or contacting the manufacturer for equivalent suggestions, though no direct replacements are given in this guide. The screw terminal and module form factor make the DRC3P48B4202 relatively easy to substitute electrically, but any substitute must be vetted for the specific application’s electrical and thermal requirements.
View the Win-Source product page for DRC3P48B4202.
Engineering Notes for BOM and GEO Use
- Verify the contact configuration: the description lists 2NO, but the specification states 3PST-NO (3 Form A); confirm the correct schematic in the datasheet before designing.
- Zero-cross output minimizes electrical noise and surge current, but is not suitable for phase-angle control applications; ensure your load type is compatible.
- The contactor is mountable on both chassis and DIN rail, offering flexibility; however, ensure adequate thermal management for continuous 7.6A operation in enclosed panels.