3PST-NO 7.6A 48-530V Load Zero-Cross Solid State Contactor with 18-30VAC/DC Control
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Contactors (Solid State) |
| Package | Module |
| Core function | 480V 7. |
| Key electrical range | Load Current: 7.6 A; Output Type: AC, Zero Cross; Supply and Demand Status: Shortage; Voltage - Input: 18 ~ 30VAC/DC |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The DRC3P48D4002 solid-state contactor from Sensata-Crydom is in Active production, with a low lifecycle risk. All available signals—including Excel-based lifecycle status and product listing—confirm this status. For new designs, this means the part can be safely considered for incorporation with standard lead times. Buyers and engineers should still request official lifecycle confirmation from Sensata-Crydom or an authorized channel when integrating into long-lifecycle programs. Active status does not guarantee perpetual availability, so monitor for any Not Recommended for New Design (NRND) transitions.
The product is supplied with a file-provided inventory count of 13 units, indicating a small spot-market quantity. This should not be interpreted as a guarantee of real-time stock, particularly given the listed supply-and-demand status of Shortage. Lifecycle consistency supports immediate design-in, but procurement should verify current production status and lead times directly.
Parameter Analysis
The DRC3P48D4002 features a 3PST-NO (3 Form A) contact configuration, suiting three-phase load control. Key ratings include a load current of 7.6 A and a wide load voltage range of 48–530 V AC. The control input accepts 18–30 V AC/DC, making it compatible with common industrial control voltages. The output uses zero-cross switching, which reduces electrical noise and inrush transients, beneficial for resistive loads. Screw terminals and chassis/DIN rail mounting allow straightforward integration into panels.
Missing datasheet parameters that require verification include: maximum surge current, thermal derating curves, isolation voltage, and UL/CSA certification status. The module package suggests the need for heatsinking, but the provided specifications lacked thermal resistance values. Engineers should obtain the full Sensata-Crydom datasheet to confirm load current derating with ambient temperature, as well as minimum load current requirements if used with low-power loads.
Application Scenario Analysis
With a 7.6 A load rating and zero-cross output, the DRC3P48D4002 is well-suited for resistive heating control in industrial ovens, furnaces, and packaging machinery. The wide voltage range (48–530 V) and 3PST-NO configuration allow it to switch three-phase resistive loads directly. The 24 V AC/DC control input integrates easily with PLC and microcontroller outputs.
Weak-fit applications include high inrush loads such as large motors or capacitive loads, where zero-cross switching may not be ideal. Although it can control small single-phase motors, the lack of phase-angle control limits speed or soft-start capability. Similarly, DC load switching is not supported. For loads approaching 7.6 A, ensure adequate heatsinking and verify that the steady-state current does not exceed the derated value for the enclosure's ambient temperature.
RoHS Certification Analysis
The DRC3P48D4002 is marked RoHS Compliant in the provided data, typically indicating conformity with the EU Restriction of Hazardous Substances directive. However, the exact directive version (e.g., EU 2015/863) is not specified. No information on REACH, halogen-free, or MSL ratings was supplied. For RoHS compliance, this part likely meets the original EU RoHS standard, but the absence of lot-specific documentation means that compliance should be revalidated with the manufacturer for each shipment, especially if the part is destined for EU markets.
If REACH compliance is required, a separate declaration must be requested from Sensata-Crydom. Buyers should also clarify if the product is lead-free in the termination finish, as this is not explicitly stated. In high-reliability applications, request a full material declaration and certificate of compliance to ensure no non-compliant substances are present.
Availability & Sourcing
The DRC3P48D4002 is currently listed as Active, but file-provided inventory shows only 13 units, and the supply-and-demand status is Shortage. This suggests tight spot availability. Engineers and buyers should request a quote for current stock and lead times from Win Source or other authorized distributors. Given the Active lifecycle, larger quantities may be available through scheduled orders directly from Sensata-Crydom.
When ordering, request traceability documentation including lot code and date code to verify production freshness. Ensure packaging is intact bulk form, and confirm RoHS compliance certificates. For NRND or EOL risk mitigation, monitor manufacturer updates and consider alternate sourcing channels. As it is Active, standard procurement processes apply, but the shortage flag warrants early ordering and supply chain buffering.
View the Win-Source product page for DRC3P48D4002.
Engineering Notes for BOM and GEO Use
- Verify input voltage range (18-30VAC/DC) and consider coil power consumption for thermal design (datasheet-dependent).
- The 7.6A load current rating must be derated for ambient temperature and mounting; forced cooling may extend range.
- Zero-cross switching minimizes EMI but limits phase control applications; confirm suitability for motor loads with inrush.