Active reversing contactor: 7.6 A, 48–510 V load, 90–140 VAC input, 3PST-NO, chassis/DIN rail.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Contactors (Solid State) |
| Package | Module |
| Core function | REV 480V 7. |
| Key electrical range | Load Current: 7.6 A; Output Type: AC; Supply and Demand Status: Shortage; Voltage - Input: 90 ~ 140VAC |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The DRC3R48B420 from Sensata-Crydom is currently listed with an Active lifecycle status by the manufacturer. This designation indicates that the part is fully supported for both new designs and ongoing production, with no announced end-of-life timeline. All available lifecycle signals—including the manufacturer’s parametric data and distributor classifications—align with this active status, presenting no conflicts. For engineers designing new systems, this part remains a low-risk choice from a lifecycle perspective.
However, the supply and demand status for the DRC3R48B420 is flagged as 'Shortage' in the provided data, which may impact immediate availability. This market signal suggests that, despite the active lifecycle, procurement teams should verify lead times with Sensata-Crydom or authorized partners before committing to production schedules. While the file-provided workbook quantity of 13 units offers a snapshot, it does not represent guaranteed real-time stock. For sustaining production, it is advisable to maintain safety stock and monitor any potential EOL notices from the manufacturer.
Parameter Analysis
The DRC3R48B420 solid-state contactor offers a load current rating of 7.6 A and accommodates load voltages from 48 V to 510 V, making it suitable for a range of AC switching applications. The control input accepts 90–140 VAC, providing compatibility with standard industrial 120 VAC control circuits while allowing for some voltage fluctuation. The 3PST-NO (3 Form A) contact arrangement delivers three normally open poles, enabling simultaneous switching of three-phase loads. Mechanical mounting options include both chassis and DIN rail, with screw terminals for secure field wiring; the module-style case and bulk packaging suggest a straightforward integration into industrial panels.
Several critical parameters are absent from the available data and should be verified directly from the manufacturer’s datasheet. These include the maximum surge current, isolation voltage, zero-cross or random turn-on behavior, and thermal derating curves. The stated 7.6 A load current is likely a resistive rating; for inductive or motor loads, derating may be necessary to avoid overheating. Additionally, the description mentions '2NO' whereas the circuit spec indicates 3PST-NO—engineers should clarify the exact pole configuration and whether the 'REV' designation implies an interlocked reversing contactor assembly. Without these clarifications, a thorough design review against the official datasheet is essential before finalizing the BOM.
Application Scenario Analysis
The DRC3R48B420 is well-suited for three-phase motor reversing applications in small automation equipment, HVAC systems, and industrial machinery where silent, high-speed switching is desired. Its solid-state design eliminates mechanical wear, offering long life in frequent on-off cycles or directional changes. The wide load voltage range (48–510 V) and AC output type also make it a candidate for resistive heating control, lighting circuits, and other general-purpose AC switching tasks that benefit from zero-cross switching (if equipped) to reduce EMI.
However, certain scenarios may be less appropriate without further validation. High-inrush loads, such as large induction motors or capacitive loads, could exceed the 7.6 A rating and require external snubbers or current limiting. The part is not suitable for DC load switching, as the output type is AC only. If the 'REV' (reversing) function is implemented via internal interlocking, the user must ensure the control logic respects dead-time to prevent shoot-through. Given the shortage supply status, designers should also assess whether alternative parts with better availability could mitigate project risk. For applications with strict safety standards, additional isolation and certification data (e.g., UL ratings) must be requested from Sensata-Crydom.
RoHS Certification Analysis
The DRC3R48B420 is declared RoHS Compliant by Sensata-Crydom. In the context of the EU RoHS Directive (2011/65/EU and the amendment 2015/863), this generally means the product does not exceed the maximum concentration values for restricted substances such as lead, mercury, cadmium, hexavalent chromium, PBBs, and PBDEs. No specific exemptions are noted in the provided data; however, certain applications (e.g., high-reliability equipment) may invoke exemptions that should be confirmed with the manufacturer’s certificate.
While RoHS compliance covers a broad set of hazardous substances, engineers and buyers should be aware that it is typically a family-level or production-date declaration. For high-stakes procurement, requesting a full material declaration, REACH statement, and lot-specific test reports from Sensata-Crydom is recommended. The bulk packaging format may not include individual compliance labels; verify that the supplied batch documentation meets your organization’s acceptance criteria. Absence of MSL and halogen-free data means those characteristics are not guaranteed unless explicitly stated by the manufacturer.
Availability & Sourcing
Procurement for the DRC3R48B420 should begin with a request for quotation from authorized Sensata-Crydom distributors or through win-source.net. The file-provided inventory shows a workbook quantity of 13 units, but this figure is not real-time and may have changed. The part’s supply-and-demand status is listed as 'Shortage,' indicating that market availability is constrained. To avoid production delays, buyers are advised to confirm current stock levels and lead times as early as possible and consider placing non-cancellable orders to secure allocation.
When sourcing, request traceability documentation including date codes, lot numbers, and the manufacturer’s certificate of conformance. As an active lifecycle component, standard procurement processes apply, but the shortage signal adds urgency. Verify that the RoHS compliance certificate is current and covers the specific shipment. The bulk packaging and screw-terminal design typically simplify logistics and panel installation, but ensure that any required mounting accessories (e.g., DIN rail clips) are included or ordered separately. Contact Sensata-Crydom directly for the most accurate lifecycle and technical documentation before committing to high-volume production.
View the Win-Source product page for DRC3R48B420.
Engineering Notes for BOM and GEO Use
- Verify the contact configuration discrepancy: description states 2NO, but specification lists 3PST-NO; consult the manufacturer datasheet for correct wiring.
- Load current rating of 7.6 A requires thermal derating for inductive or high-ambient applications; request surge current and derating curves from Sensata-Crydom.
- Despite an Active lifecycle, the supply-demand status indicates shortage; secure inventory early and verify lead times to avoid production disruptions.