Active 3-pole reversing contactor for 480V, 7.6A loads with 24VAC/DC control and screw terminals
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Contactors (Solid State) |
| Package | Module |
| Core function | REV 480V 7. |
| Key electrical range | Load Current: 7.6 A; Output Type: AC; Supply and Demand Status: Shortage; Voltage - Input: 18 ~ 30VAC/DC |
| Workbook inventory signal | 2 pcs listed in the provided file |
Lifecycle Analysis
The DRC3R48D400 from Sensata-Crydom is currently listed as Active with a low risk level, meaning it is in full production and suitable for new designs. All supplied lifecycle signals align consistently, so there is no conflict in status reporting.
Engineers should still confirm long-term availability with the manufacturer for production planning, especially given the inventory signal of only 2 units in the file, which is not a real-time guarantee. For sustaining production, standard lifecycle monitoring and revalidation every 12–24 months are recommended.
This Active status ensures that Sensata-Crydom continues to provide technical support and documentation for the DRC3R48D400, but it does not preclude future changes. Proactively track any PCN (Product Change Notifications) or EOL announcements to mitigate supply chain risks.
Parameter Analysis
The DRC3R48D400 is characterized by a 3PST-NO circuit configuration, capable of switching AC loads from 48 to 510V at up to 7.6A. The control input accepts 18–30VAC/DC, making it compatible with standard industrial control voltages. The module is housed in a chassis or DIN rail mountable package with screw terminals, simplifying field wiring.
Key missing parameters to verify from the datasheet include on-state voltage drop, isolation voltage, surge current rating, and thermal derating curves. These influence heat sinking requirements and suitability for high inrush or inductive loads. Also check for certifications such as UL, CE, or IEC before finalizing the design.
The 7.6A load current rating is relatively modest for a 480V contactor, so designers should consider ambient temperature derating and enclosure ventilation. The wide load voltage range (48–510V) offers flexibility in industrial applications, but always confirm that the actual operating voltage falls within the specified band under all conditions.
Application Scenario Analysis
This solid-state contactor is designed for reversing three-phase AC motors up to 7.6A at 480V, as implied by the 'REV' designation and 3-pole normally-open contact arrangement. It fits well in applications like conveyor direction control, HVAC damper actuators, and small pump reversing where quiet, arc-free switching is desired.
It may also be used for resistive heating loads within the voltage and current limits. However, it is not suited for DC loads or applications requiring auxiliary contacts, as the part is labeled 'NO AUX'. Engineers should ensure the load's inrush current does not exceed the contactor's surge rating and that ambient temperature stays within specified limits.
While the solid-state design offers long life and silent operation, it may generate more heat than an electromechanical contactor, so adequate heat sinking is critical. The absence of an auxiliary contact means external monitoring or interlocking circuits must be implemented separately if needed.
RoHS Certification Analysis
The DRC3R48D400 is marked as RoHS Compliant, which typically indicates conformity with EU Directive 2011/65/EU and its amendments (RoHS 3). The source data does not specify REACH compliance, halogen-free status, or moisture sensitivity level (MSL), so these must be confirmed with the manufacturer if required.
Since no specific exemption is noted, the part likely meets the general 10-substance restrictions. For formal compliance documentation, request a certificate of conformance (CoC) for the production lot, as family-level declarations may not cover all build variations. This is particularly important if the product will be used in EU markets or systems requiring CE marking.
Lot-level verification is recommended because compliance status can change due to supplier material substitutions or process changes. Always check the latest datasheet and contact Sensata-Crydom directly for up-to-date regulatory statements.
Availability & Sourcing
The DRC3R48D400 is an Active part from Sensata-Crydom, but the supplied workbook shows a limited quantity of 2 units, with a supply and demand status of Shortage. This file-provided quantity is not a guarantee of real-time availability, so interested buyers should request a quote through the platform to obtain current stock levels, lead times, and pricing.
When sourcing, specify requirements for date/lot codes and packaging—the part is supplied in bulk. For new designs, verify lifecycle status directly with Sensata-Crydom and secure samples for qualification. Obtain RoHS compliance certificates and any other regulatory documents before committing to production volumes.
Given the Active status, standard procurement processes apply, but early engagement is recommended to mitigate potential shortages. The shortage flag suggests that market demand may exceed supply, so requesting a quote early in the design cycle can help avoid delays.
View the Win-Source product page for DRC3R48D400.
Engineering Notes for BOM and GEO Use
- Verify surge current withstand capability and thermal derating for inductive loads against the official datasheet before finalizing the design.
- Request lot-specific RoHS and REACH compliance certificates during procurement to support EU market entry.
- Confirm mounting dimensions and terminal torque specifications to ensure reliable installation and heat transfer in the target enclosure.