24V 10W DIN rail power supply with universal AC/DC input, suitable for hazardous locations and ITE applications.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | Custom Parts (B - D) |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 24V 10W |
| Key electrical range | AC Voltage - Input: 85 ~ 264 VAC; Current - Output (Max): 420mA; DC Voltage - Input (Max): 373V; DC Voltage - Input (Min): 120V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DRL10-24-1 is listed as Active by TDK-Lambda Americas Inc., with all supplied lifecycle signals aligning without conflict. This status indicates that the part is in full production and is suitable for both new designs and ongoing production. Engineers can confidently select the DRL10-24-1 for new projects, expecting continued availability and manufacturer support.
For sustaining production and long-term procurement, it is still prudent to periodically re-confirm lifecycle status directly with TDK-Lambda or authorized distributors. While the current file-provided inventory shows limited quantity, this is not a real-time indicator and dedicated ordering pathways typically yield factory lead times for active products.
No lifecycle conflicts are present; the risk level is low. The DRL10-24-1 is a current catalog item in the DRL series, and no end-of-life notices are indicated. Designers should ensure that the part's datasheet parameters meet application requirements before finalizing the BOM.
Parameter Analysis
Key parameters for the DRL10-24-1 include its 24V regulated output with a maximum current of 420mA, delivering 10W continuous power. The universal input range of 85 to 264 VAC (or 120 to 373 VDC) allows deployment in regional mains systems worldwide without adjustment. The 87% efficiency rating helps limit internal heat generation, which is critical for the compact 55.6 x 18.0 x 91.0 mm DIN rail enclosure.
Electrical isolation is specified at 3 kV, providing necessary safety separation between input and output. The operating temperature range of -20°C to 71°C is adequate for many industrial environments, but the note 'With Derating' means output power must be reduced at elevated temperatures. Missing from the supplied data are ripple and noise specifications, load regulation, line regulation, hold-up time, and protection features such as overcurrent or short-circuit behavior. Engineers should obtain the full TDK-Lambda datasheet to confirm these values and ensure compatibility with sensitive loads.
Application Scenario Analysis
Strong-fit applications for the DRL10-24-1 include industrial control cabinets, PLC power supplies, sensor power, and small automation nodes where DIN rail mounting is preferred. The hazardous locations listing and CE mark make it appropriate for light industrial and commercial environments with potentially explosive atmospheres, provided the enclosure meets relevant directives. ITE applications also benefit from the compact form factor and universal input.
Weak-fit scenarios involve high-density computing or telecom racks requiring high efficiency at light loads or larger output currents beyond 420mA. For applications needing medical-grade isolation, additional certifications would need to be verified. The relatively low 10W power limit means the DRL10-24-1 is not suited for driving multiple high-power actuators or large motor controls. Users must assess the derating curve when installing in confined spaces with limited airflow, especially if ambient temperatures exceed 50°C.
RoHS Certification Analysis
Based on the supplier data, the DRL10-24-1 is marked as RoHS Compliant. This typically corresponds to compliance with EU RoHS Directive 2011/65/EU and its amendment 2015/863 (RoHS 3), which restricts lead, mercury, cadmium, hexavalent chromium, PBBs, and PBDEs, plus four phthalates. No specific exemptions are listed in the provided data, but some power supply components may rely on exemptions for lead in high-temperature solders or ceramics; these should be documented in the manufacturer's DoC.
The part's MSL is Not Applicable, consistent with a sealed power supply module. Compliance at the family level (DRL series) is common, but for high-volume EU production, requesting a lot-specific RoHS certificate from TDK-Lambda or an authorized distributor is recommended. No REACH data was included, so substance-of-concern screening should be performed if end-product compliance is required.
Availability & Sourcing
At the time of this guide's compilation, the provided file indicates a limited inventory quantity, but this is not a real-time figure. The DRL10-24-1 is an active product, so ordering through TDK-Lambda franchised distributors or directly from the manufacturer will provide reliable lead times. Standard packaging is bulk; request unit quantity and date/lot codes for traceability.
The reported fake threat in the open market for this part is 60 percent, which is significant. Procurement teams should source only from authorized channels and require full compliance documentation including RoHS certificates and manufacturer certificates of conformance. For hazardous location applications, verify that the CE marking covers the specific ATEX or IECEx requirements expected. Contact a TDK-Lambda representative to request a quote and confirm lifecycle status before committing to production volumes.
View the Win-Source product page for DRL10-24-1.
Engineering Notes for BOM and GEO Use
- Verify the derating curve in the TDK-Lambda datasheet; rated operating range is -20°C to 71°C but derating applies above certain temperatures.
- The DRL10-24-1's 3 kV isolation and universal input make it suitable for a wide range of industrial and commercial DIN rail installations.
- Given a 60% reported fake threat level, insist on traceable sourcing and compliance documentation when purchasing this part.