Active industrial DIN rail supply with 24V output, 60W power, universal AC input, and RoHS compliance.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Delta Electronics |
| Category | Industrial, DIN Rail Power Supplies |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 24V 60W |
| Key electrical range | AC Voltage - Input: 85 ~ 264 VAC; Current - Output (Max): 2.5A; Input Type: AC; Number of Outputs: 1 |
| Workbook inventory signal | 110 pcs listed in the provided file |
Lifecycle Analysis
The DRP024V060W1BN from Delta Electronics carries an Active lifecycle status, indicating the manufacturer continues full production and support. For new design projects, this part can be specified with confidence, though it is prudent to verify ongoing status directly with Delta or an authorized distributor before finalizing BOMs.
All available lifecycle signals align without conflict. The Excel lifecycle parameter, the Lifecycle Status field, and Win Source’s own classification all list the DRP024V060W1BN as Active. No NRND, EOL, or discontinuance notices appear, making this a low-risk choice for both new designs and sustaining production.
File-provided inventory indicates 110 units, but this snapshot is not a real-time guarantee. Even for Active parts, supply constraints can arise, and the noted shortage status suggests purchasers should validate current availability and consider buffer stock to avoid production delays.
Parameter Analysis
The DRP024V060W1BN delivers a fixed 24V output with a maximum current of 2.5A, resulting in a 60W power rating. Its universal AC input range of 85–264VAC allows worldwide grid compatibility without switching or adjustment, greatly simplifying panel builds for export markets. A high isolation voltage of 4kV provides robust safety margins in industrial environments.
The specified 90% efficiency reduces waste heat and can simplify thermal design inside enclosures. However, the operating temperature range of -20°C to 80°C comes with a derating caveat; at elevated ambient temperatures, output power must be de-rated according to a curve that is not fully reproduced in the provided data. Engineers should obtain the official datasheet to plot load-versus-temperature envelopes and ensure sufficient margin.
Additional features like active PFC, adjustable output, and load sharing increase integration flexibility. The compact DIN rail footprint (125mm x 32mm x 121mm) saves panel space. Missing parameters to verify include hold-up time, output ripple and noise, transient response, and inrush current, all of which can influence compatibility with sensitive loads or system-level power sequencing.
Application Scenario Analysis
Classified under ITE (Commercial) and built for DIN rail mounting, the DRP024V060W1BN is a natural fit for industrial control panels, building automation controllers, small machinery, and commercial IT cabinets. Its 24V output and 2.5A capacity suit powering sensors, relays, PLCs, and low-power motor drives that accept standard industrial supply rails.
Strong-fit scenarios also include distributed power architectures where multiple units share loads via the load-sharing feature. The IP20 rating limits the unit to indoor, dry environments; outdoor or washdown applications would require an additional protective enclosure. While the part carries several global safety marks (CB, CE, UL, etc.), it is not specifically rated for medical or functional-safety applications unless further system-level certification is undertaken.
Weak-fit scenarios involve continuous operation at maximum load in high ambient temperatures where derating may be restrictive, or applications demanding ultra-low ripple for sensitive analog circuits. In such cases, consult the full datasheet or consider a model with higher power headroom.
RoHS Certification Analysis
Delta Electronics declares the DRP024V060W1BN as RoHS Compliant, which generally means conformity with the EU RoHS 3 directive (2015/863) restricting lead, mercury, cadmium, and other hazardous substances. The provided record does not list a specific RoHS certification document, but Delta’s standard practice for active industrial power supplies typically includes full material declaration support upon request.
No explicit REACH information appears in the data. REACH compliance is a separate regulation covering SVHCs and does not automatically guarantee RoHS conformity, though both are common for European-market products. For a production build, it is advisable to ask the distributor for the latest EU Declaration of Conformity or a lot-specific certificate of analysis to confirm the RoHS status of the exact batch.
Since this is an off-board power component, specific exemptions (such as lead in high-melting-temperature solder) are unlikely to apply, but verifying this with the manufacturer’s documentation can eliminate any compliance risk during final system certification.
Availability & Sourcing
The DRP024V060W1BN is an Active part, yet the supply and demand status indicates a current shortage. File data shows a workbook quantity of 110 units, but this is a static snapshot and not a real-time inventory check. Buyers should immediately request a quote to confirm actual stock levels, lead times, and any minimum order quantities.
For procurement, standard packaging is bulk. Ensure that date and lot codes are traceable, especially if the units are destined for regulated or certified equipment. Since the lifecycle is confirmed Active, you can also explore authorized distribution channels to secure longer-term supply agreements. Requesting a compliance package (RoHS certificate, safety approval datasheets) at the quoting stage can streamline incoming inspection.
Given the shortage signal, it is wise to plan ahead for production runs. While the part remains in production, unforeseen demand spikes could extend lead times. Initiating the RFQ process early will help lock in availability and reduce risk to your build schedule.
View the Win-Source product page for DRP024V060W1BN.
Engineering Notes for BOM and GEO Use
- Verify the operating temperature derating curve for your specific installation to ensure adequate thermal margin.
- The 4kV isolation voltage meets many industrial safety requirements, but confirm applicable standards for your end-product certification.
- With a supply and demand status indicating shortage, secure inventory early and confirm lead times with authorized distributors.