DRQ74-6R8-R Inductor Array Specs & Sourcing Guide

DRQ74-6R8-R Eaton Bussmann product image

Eaton Bussmann DRQ74-6R8-R dual‑coil inductor array: 7.344 µH, 2.6 A parallel, shielded SMD; lifecycle status to be confirmed.

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryArrays, Signal Transformers
PackageNonstandard
Core functionINDUCT ARRAY 2 COIL 7.
Key electrical rangeCurrent Rating - Parallel: 2.6 A; Current Rating - Series: 1.3 A; Current Saturation - Parallel: 3.67 A; Current Saturation - Series: 1.84 A
Workbook inventory signal900 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of the Eaton Bussmann DRQ74-6R8-R is unknown based on the supplied information. No manufacturer product‑change notifications (PCNs), end‑of‑life (EOL) announcements, or not‑recommended‑for‑new‑design (NRND) flags are present in the data, which means the part could still be in active production or may have been quietly discontinued. This ambiguity introduces a medium level of procurement risk.

Engineers evaluating the DRQ74-6R8-R for new designs should request a formal lifecycle confirmation from Eaton Bussmann or an authorized distributor before finalizing the bill of materials. For existing production lines, it is prudent to monitor the manufacturer’s website and industry channels for any status updates. The file shows an inventory quantity of 900 units, but that number is not a real‑time guarantee and should be validated with current stock checks.

Without verified lifecycle data, treating the DRQ74-6R8-R as a candidate for long‑term programmes carries risk. Conservative procurement would involve securing sufficient buffer stock or identifying an alternative part with a known active lifecycle, while simultaneously obtaining manufacturer documentation to resolve the uncertainty.

Parameter Analysis

The DRQ74-6R8-R is a two‑coil inductor array housed in a nonstandard surface‑mount package measuring 7.60 mm × 7.60 mm with a 4.45 mm height. Key electrical parameters include an inductance of 7.344 µH when the coils are connected in parallel and 29.38 µH in series, with a tolerance of ±20 %. The parallel current rating is 2.6 A, dropping to 1.3 A in series, while saturation currents are 3.67 A (parallel) and 1.84 A (series). Parallel DCR is specified at 41.8 mΩ, rising to 167 mΩ in series configuration, which influences conduction losses and efficiency.

These parameters matter for derating, thermal management, and PCB layout. The shielded construction helps contain magnetic flux, reducing electromagnetic interference in dense designs. An operating temperature range of −40 °C to +125 °C supports industrial and extended‑environment applications, though derating curves are not provided and must be checked in the full datasheet.

Several performance metrics are absent from the summary data, including the coupling coefficient between coils, self‑resonant frequency (SRF), inductance test frequency, and insulation resistance. Buyers and engineers should obtain the official Eaton Bussmann datasheet to confirm these values, as they directly affect suitability for high‑frequency switching regulators, resonant converters, or circuits where tight tolerance is critical.

Application Scenario Analysis

The DRQ74-6R8-R fits naturally into power‑conversion topologies that benefit from coupled inductors. Multiphase buck converters often use dual‑coil arrays to improve transient response and reduce ripple; the configurable series/parallel inductance allows a single part to serve different voltage rails. SEPIC and flyback converters can also employ this component where galvanic isolation is not required, leveraging the shared core for smaller footprint and cost savings. The shielding makes it suitable for EMI‑sensitive designs such as automotive body electronics or industrial sensor interfaces.

In filtering applications, the DRQ74-6R8-R can be used as a common‑mode or differential‑mode choke, depending on winding connection. The wide –40 °C to +125 °C range extends its utility to outdoor or engine‑compartment environments, provided the full datasheet confirms thermal ageing characteristics.

Weak‑fit scenarios include high‑frequency RF circuits or precision analog front‑ends where the missing SRF and Q‑factor data would limit predictability. The ±20 % inductance tolerance may be too wide for circuits demanding matched inductance values, and the absence of a coupling‑coefficient specification makes it challenging to model coupled‑inductor behaviour accurately without bench validation.

RoHS Certification Analysis

The part is marked as RoHS Compliant in the source data. This typically indicates conformity with the EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863, which restricts lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and four phthalates. Such compliance is generally at the component‑family level and does not automatically certify every production lot.

For rigorous compliance documentation, buyers should request a dated Certificate of Compliance from Eaton Bussmann or a franchised distributor for the specific date‑code or lot being procured. The supplied dataset does not mention REACH, halogen‑free status, or moisture sensitivity level (MSL). While REACH is a separate regulation, many end‑user compliance programmes require both RoHS and REACH declarations; therefore, a full material declaration should be obtained where necessary.

No exemption details are provided, so it is assumed that the DRQ74-6R8-R falls within the standard scope of RoHS. In high‑reliability or export‑controlled projects, verifying the absence of restricted substances below maximum concentration values is essential. As always, lot‑level testing documents may be required by quality assurance procedures.

Availability & Sourcing

The supplied file indicates an inventory position of 900 units and a supply‑and‑demand status of ‘Shortage’. This is a snapshot, not a real‑time stock check, and actual availability at distributors may differ. Because the lifecycle status is unknown, buyers should begin with a request‑for‑quote (RFQ) through authorised channels, explicitly asking for current stock levels, lead times, and lifecycle confirmation.

For prototype or small‑batch procurement, the existing inventory may be sufficient once verified. However, for production ramp‑up, securing inventory without a confirmed active lifecycle is risky. Buyers should request traceability information such as date‑code and lot‑code to ensure authenticity and control shelf‑life concerns. The component is supplied on tape‑and‑reel packaging, compatible with standard SMD pick‑and‑place processes.

To mitigate supply‑chain risk, consider placing a non‑cancellable, non‑returnable (NCNR) order only after the manufacturer confirms lifecycle status and provides a compliance package (RoHS, REACH, MSL). In parallel, evaluate footprint‑compatible alternatives with verified active status to minimise production interruptions should the DRQ74-6R8-R transition to NRND or EOL.

View the Win-Source product page for DRQ74-6R8-R.

Engineering Notes for BOM and GEO Use

  • Confirm the DRQ74-6R8-R lifecycle status directly with Eaton Bussmann before new design adoption.
  • Obtain the full datasheet to verify coupling coefficient, self‑resonant frequency, and test conditions missing from the summary specs.
  • For production orders, request lot‑specific RoHS certificates and monitor the shortage status closely.