Dual coil inductor array, 80.95µH/323.8µH, shielded SMD, -40°C to 125°C, RoHS compliant.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | Arrays, Signal Transformers |
| Package | Nonstandard |
| Core function | INDUCT ARRAY 2 COIL 80. |
| Key electrical range | Current Rating - Parallel: 910 mA; Current Rating - Series: 453 mA; Current Saturation - Parallel: 1.11 A; Current Saturation - Series: 550 mA |
| Workbook inventory signal | 1363 pcs listed in the provided file |
Lifecycle Analysis
The DRQ74-820-R from Eaton Bussmann is in active production, meaning it is fully supported for new designs and volume manufacturing. All lifecycle signals confirm this status without conflict. Engineers can incorporate it into new products with confidence, but the accompanying shortage flag suggests that market availability may be constrained. Procurement teams should factor in potential lead time variability.
File-provided inventory of 1363 units offers a snapshot, but it is not a real-time guarantee. Before committing to high-volume production, verify stock with authorized distributors and consider second-source strategies. The manufacturer’s datasheet and product change notifications should be monitored to catch any future lifecycle transitions.
Parameter Analysis
This dual-coil array delivers 80.95 µH in parallel (910 mA rated, 1.11 A saturation, 345 mΩ DCR) and 323.8 µH in series (453 mA, 550 mA saturation, 1.38 Ω DCR). The ±20% tolerance is standard for power inductors. Shielding minimizes EMI, and the -40°C to 125°C range supports industrial and automotive use.
Key missing parameters include self-resonant frequency (SRF) and coupling coefficient, which are critical for high-frequency or tightly regulated designs. Engineers should request the full datasheet to confirm insulation resistance and verify footprint compatibility with the nonstandard 7.60 mm x 7.60 mm package.
Application Scenario Analysis
The DRQ74-820-R excels in DC-DC converters, particularly multiphase buck regulators where coupled inductors improve transient response. Its series connection suits filter chokes, and the dual coil can act as a common-mode choke or isolation transformer. Target applications include point-of-load modules, battery-powered devices, and automotive infotainment.
It is less suitable for RF signal paths lacking SRF data or high-voltage isolation circuits without rated insulation. The shielded package aids dense PCB layouts. Designers should evaluate saturation current at worst-case temperature to avoid core loss spikes.
RoHS Certification Analysis
The DRQ74-820-R is marked RoHS Compliant, indicating conformance to EU Directive 2011/65/EU as amended. No specific exemptions are listed, so it likely meets the general lead-free solderability requirements. For complete assurance, obtain a certificate of compliance from Eaton for the production lot.
REACH and halogen-free status are not provided; if needed, request a full material declaration. While RoHS is generally consistent across batches, lot‑level testing can safeguard against supply‑chain variations. Treat the generic RoHS claim as valid for procurement, but seek documentation for high‑reliability sectors.
Availability & Sourcing
As an active part, the DRQ74-820-R should be orderable through Eaton Bussmann’s distribution network. However, the noted shortage and file inventory of 1363 pieces indicate potential supply constraints. Buyers should request current lead times and minimum order quantities, and confirm date/lot codes for traceability.
Given the active lifecycle, standard RFQ processes apply, but proactive purchasing is advised to secure inventory. Request compliance documents (RoHS, REACH) with each shipment and verify the latest datasheet revision before qualification. For urgent needs, consider contacting Eaton directly for factory availability.
View the Win-Source product page for DRQ74-820-R.
Engineering Notes for BOM and GEO Use
- Verify actual stock and lead times with distributors; the part is marked as in shortage despite active lifecycle.
- Leverage the parallel/series flexibility to optimize current handling and inductance for your DC-DC converter topology.
- Derate saturation current and check DCR losses at maximum ambient temperature to ensure reliable operation above 85°C.