Sensata-Crydom DRS1 Relay Socket Specs & Sourcing Guide

DRS1 Sensata-Crydom product image

4-Position DIN Rail Socket for CX and CMX Series — Sourcing & Compliance Guide

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategoryRelay Sockets
PackageBox
Core functionRELAY SOCKET 4 POSITION DIN RAIL
Key electrical rangeSupply and Demand Status: Shortage
Workbook inventory signal5 pcs listed in the provided file

Lifecycle Analysis

The DRS1 relay socket carries an Active lifecycle status from Sensata‑Crydom, with no conflicting data across available signals. This classification means the manufacturer intends to continue production and support, making the DRS1 a safe choice for both new design starts and sustaining production lines. Engineers can incorporate the DRS1 into new schematics without immediate risk of obsolescence.

However, the file‑provided inventory of 5 units should not be taken as a real‑time stock guarantee. Buyers should request a current availability check and lead‑time quote when planning orders. The Active status generally implies low supply chain risk, but periodic revalidation—especially for safety‑critical or long‑lifecycle equipment—remains good practice. Monitoring Sensata‑Crydom’s official product notifications will ensure that any future change notices for the DRS1 are captured early.

Parameter Analysis

Key parameters for the DRS1 include a 4‑position configuration, DIN rail mounting, and screw terminal connections. The 4‑position count determines relay compatibility, so verifying the pinout of the intended CX or CMX relay against the DRS1 socket is critical. The DIN rail footprint simplifies mechanical integration into standard industrial enclosures, while screw terminals enable tool‑free, reliable field wiring—a significant advantage over solder or push‑in styles in maintenance‑prone environments.

The provided data lacks electrical ratings such as current per contact, dielectric strength, and insulation class. Without these specifications, designers must rely on the associated relay’s datasheet and assume the DRS1 socket is rated to match. It is also important to check the operating temperature range and UL/CSA recognition status directly with Sensata‑Crydom, as these influence panel‑level certification. For PCB‑based designs, note that the DRS1 is a socket, not a PCB‑mount component, so layout considerations are mechanical rather than electrical.

Application Scenario Analysis

The DRS1 is purpose‑built for industrial relay applications that use Sensata‑Crydom’s CX and CMX series. Typical scenarios include motor control panels, heating and lighting systems, and automation controllers where DIN rail mounting is standard. The screw terminal design suits applications requiring frequent re‑wiring or field service, such as HVAC controls and machinery I/O modules.

In contrast, the DRS1 may not be an optimal fit for compact devices needing PCB‑mounted relay sockets, or for high‑density panels where spring‑cage terminals reduce wiring time. Additionally, if the target relay is not from the CX or CMX families, engineers must verify the socket’s pin arrangement and retention mechanism; using the DRS1 with unlisted relays could cause intermittent connections or mechanical misalignment. For environments with high shock or vibration, confirm that the DIN rail clip provides adequate retention beyond the standard latching force.

RoHS Certification Analysis

The DRS1 is listed as RoHS Compliant by the supplier. This status generally indicates adherence to EU Directive 2011/65/EU and its amendment 2015/863, restricting hazardous substances like lead, mercury, and cadmium. However, the provided metadata does not include a formal certificate number or version, so procurement teams should not rely solely on the database marker.

To fully satisfy compliance documentation needs, request the manufacturer’s CE declaration and a detailed RoHS certificate for the specific lot being purchased. The absence of REACH or halogen‑free statements in the source data means those obligations must be verified separately. Family‑level compliance claims are common, but lot‑level testing or supplier declarations provide the strongest audit trail for the DRS1 in regulated industries such as medical or aerospace.

Availability & Sourcing

The Sensata‑Crydom DRS1 is an Active component, but file‑based inventory shows only 5 units and a shortage status. This snapshot reflects provider data and is not a real‑time stock guarantee. Engineers and buyers should initiate an RFQ through authorized channels to obtain current lead times, available quantities, and packaging options. The standard package is Box, which may affect handling costs for high‑volume orders.

Sourcing strategy should include verifying date and lot codes to ensure fresh stock and full traceability. Request the RoHS certificate and any applicable CB test certificates during RFQ to pre‑qualify the DRS1 for production. As an Active part, the primary action is to quote and validate compliance documents; if lead times are extended, consider advanced purchasing or safety stock to hedge against the reported shortage. Always reconfirm lifecycle status with the manufacturer before placing large orders to protect against sudden obsolescence updates.

View the Win-Source product page for DRS1.

Engineering Notes for BOM and GEO Use

  • Verify electrical ratings and derating for load currents in the target application; DRS1 socket data is sparse and must be confirmed with the relay and load.
  • Confirm mechanical and pinout compatibility with CX and CMX series relays; using other relay families may require a different socket or adapter.
  • Request Sensata‑Crydom’s RoHS certificate and full material declaration for each DRS1 lot to ensure compliance across the supply chain.