16-position DIN rail mount socket for CX and CMX series solid state relays. Active lifecycle.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Relay Sockets |
| Package | Box |
| Core function | RELAY SOCKET 16 POS DIN RAIL |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 10 pcs listed in the provided file |
Lifecycle Analysis
The DRS4 relay socket is classified as Active lifecycle by the manufacturer, with all available signals aligning without conflict. This rating means the part is currently in full production, supported for new designs, and typically has no immediate end-of-life risk. For engineers planning new control panels or automation upgrades, the DRS4 represents a low-risk commodity-level socket.
Despite the Active tag, lifecycle status is a point-in-time assertion. Procurement teams should revalidate lifecycle directly with Sensata-Crydom or an authorized distributor at the time of order, especially for strategic builds. The file-provided inventory of 10 units is not an indicator of market depth; it simply reflects a snapshot of available stock.
For sustaining production, no immediate action is required beyond standard lifecycle monitoring. However, any unexpected change to NRND or EOL would demand a transition plan and last-time-buy analysis. Always check for manufacturer product change notifications (PCNs) when using the DRS4 in safety-related or certified designs.
Parameter Analysis
Key differentiating parameters for the DRS4 are its 16-position layout, DIN rail mounting, screw terminal termination, and compatibility with Sensata-Crydom’s CX and CMX relay series. The 16 total terminals, with 4 per relay, suggest the socket can accommodate up to four individual solid state relays, which helps consolidate panel wiring and reduce the number of discrete socket assemblies.
DIN rail mounting is standard for industrial control enclosures, allowing for tool-free snap-on installation and easy repositioning. Screw terminals provide a robust, vibration-resistant connection suitable for field wiring, although they require proper torque and periodic inspection. Compatibility with CX and CMX relays is critical—this socket is not a generic part, and using other relay series may lead to pin mismatch, clearance issues, or unreliable electrical contact.
Missing from the supplied data are electrical ratings (voltage, current), insulation voltage, creepage/clearance distances, wire gauge range, operating temperature range, and material flammability class. Any thermal or safety qualification must start with obtaining the full manufacturer datasheet. For high-density panels, also verify the physical footprint and required rail length.
Application Scenario Analysis
The DRS4 socket is purpose-built for industrial control applications where CX or CMX solid state relays are used for switching loads such as heaters, motors, solenoids, or lamps. Its DIN rail form factor integrates cleanly into control cabinets, PLC I/O panels, and automation sub-assemblies. The 16-terminal capability enables compact installation of multiple relays, reducing wiring clutter and enclosure space.
Strong-fit scenarios include building automation, packaging machinery, HVAC control, and power distribution panels where DIN rail mounting is the standard. The screw terminals appeal to field-serviceable systems where wiring changes or relay replacements occur. In these environments, the socket’s secure termination helps maintain long-term reliability.
Weak-fit scenarios include high-vibration mobile equipment, where DIN rail retention may require additional brackets, and aerospace or military applications unless the socket is formally qualified to relevant shock/vibration standards. The DRS4 is not designed for through-hole PCB mounting; its brick-like socket and screw terminals are oriented toward panel wiring. Before designing in, confirm that the expected ambient temperature and enclosure ventilation fall within the socket’s rated operating range.
RoHS Certification Analysis
The DRS4 is listed as RoHS Compliant, which generally indicates conformance to EU RoHS directives restricting hazardous substances such as lead, mercury, cadmium, and certain flame retardants. However, the specific directive revision (e.g., 2011/65/EU, amended by 2015/863) is not provided. This leaves ambiguity regarding the exact compliance standard and any exemptions that may apply.
For formal qualification, especially when exporting to the EU or needing CE marking, request a full RoHS certificate of compliance from Sensata-Crydom or their authorized distributor. Certificates can be lot-specific, and family-level declarations may not cover every production batch. If REACH SVHC reporting is required, a separate statement is necessary—REACH is not covered by a RoHS declaration.
From a sourcing perspective, the RoHS Compliant tag is sufficient for initial screening, but it should not replace due diligence. Always retain compliance records in your technical file, and for high-reliability products, consider periodic re-verification.
Availability & Sourcing
Current file-provided inventory indicates a quantity of 10 units for the DRS4, with a supply-and-demand status flagged as Shortage. This suggests constrained market availability, so prompt RFQ action is advisable. Remember that file data is a snapshot, not real-time; contact your sourcing partner to confirm live stock, lead time, and minimum order quantities.
Given the Active lifecycle, normal procurement channels apply: request a quote that includes date/lot code traceability, verify that packaging matches the specified Box format, and ask for a compliance pack (RoHS certificate, origin, and any required environmental statements). For production volumes, consider negotiating a vendor-managed inventory or scheduling regular releases to hedge against further shortages.
Engineers should treat even an Active part with short supply cautiously. Order adequate samples for qualification and first-article testing, as lead times can fluctuate. If the DRS4 is critical for ongoing production, initiate alternative sourcing evaluation early—though no direct substitutes are presented, understanding the forced migration path (e.g., to a different socket or relay series) reduces supply risk.
View the Win-Source product page for DRS4.
Engineering Notes for BOM and GEO Use
- Verify current/voltage ratings and temperature range from the official DRS4 datasheet before integration.
- Confirm physical depth and wire gauge compatibility for your panel, as screw terminals may limit conductor size.