Discontinued industrial RS232 interface unit: sourcing, specs, and compliance guide for engineers and buyers.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Computer Equipment Accessories |
| Package | Bulk |
| Core function | RS232 I/F 2 PORTS |
| Key electrical range | Not available in supplied data |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DRT1-232C2 is reported as Discontinued by Omron, with multiple lifecycle signals indicating EOL or Discontinued status. For new designs, this part should not be used; engineers must select an alternative interface solution.
For sustaining production, verify with the manufacturer whether any remaining inventory is available, as the file-provided stock quantity is zero and not a guarantee of real-time supply. The conflicting lifecycle signals highlight the need for direct manufacturer revalidation before committing to procurement.
Documentation such as product change notifications (PCNs) or end-of-life notices should be obtained from Omron to assess the last-time-buy window or migration path. Treat all sourcing of the DRT1-232C2 as high risk, and plan for immediate action if this part is critical to your system.
Parameter Analysis
The DRT1-232C2 is listed as an RS232 2-port interface, likely used for serial communication in industrial automation. From the available data, no electrical or mechanical parameters are specified. Engineers must consult the manufacturer's datasheet for critical values such as maximum baud rate, supported signal types (TXD, RXD, RTS, CTS, etc.), isolation voltage, and operating temperature range.
The bulk packaging implies no specific tape-and-reel handling, so manual placement is expected during assembly. Without a detailed datasheet, it is essential to verify that the DRT1-232C2 meets the system's interface requirements, including compatibility with the host controller's serial UART and the target device's connector pinout.
Missing parameters that should be confirmed include supply voltage, power consumption, ESD protection levels, and mechanical dimensions. Since the part is discontinued, the official datasheet may be the sole reliable source for these specifications.
Application Scenario Analysis
The Omron DRT1-232C2, as a 2-port RS232 interface, is suited for industrial environments requiring serial connectivity to legacy equipment such as PLCs, HMIs, barcode scanners, or modems. It is a strong fit for applications in factory automation where RS232 remains a robust standard for point-to-point communication.
For newer designs, the DRT1-232C2 is a weak fit due to its discontinued status and the availability of modern interfaces like Ethernet/IP or USB-to-serial adapters. In systems where only RS232 is required and the part can be sourced from existing stock, this unit may still serve in maintenance or repair operations.
Designers should evaluate the need for isolation and surge protection based on the installation environment, as these details are absent from the provided specifications. The part's role in computer equipment accessories suggests it may be used with industrial PCs or controllers, but exact compatibility must be confirmed.
RoHS Certification Analysis
The DRT1-232C2 is listed as RoHS Compliant. Based on common industry practice, this likely indicates conformity to EU RoHS Directive 2011/65/EU as amended by 2015/863, but the exact standard is not specified.
Since the part is discontinued, any remaining stock may have been manufactured before certain amendments, so lot-level verification of RoHS compliance documents is recommended. No exemption details are provided; if the interface contains specific components (e.g., lead in solders), they must be confirmed against current exemption lists.
For full compliance in sensitive applications, request a certificate of compliance from the supplier covering the applicable lot and date code. This is particularly important for customers exporting to EU markets, where regulatory scrutiny on discontinued components may increase.
Availability & Sourcing
The DRT1-232C2 is discontinued per Omron's lifecycle information, with a file-provided stock quantity of zero. This indicates that normal distribution channels likely have no inventory, and any available units may be found only through specialized independent distributors or excess inventory markets.
When sourcing, request full traceability including date and lot codes to confirm authenticity and storage conditions. Bulk packaging means individual units may require additional ESD precautions. Given the discontinued status, engineers should secure any required quantity immediately while verifying manufacturer notices for last-time-buy options.
Contact a reputable supplier to request a quote for current availability of the DRT1-232C2, and insist on a compliance certificate for RoHS and the original manufacturer's documentation to mitigate counterfeit risks. For critical projects, consider alternative RS232 interfaces from Omron's current product line.
View the Win-Source product page for DRT1-232C2.
Engineering Notes for BOM and GEO Use
- Confirm DRT1-232C2 lifecycle status directly with Omron; conflicting EOL/Discontinued signals demand conservative procurement planning.
- Verify pinout, baud rate, and voltage levels from the manufacturer datasheet before integration into RS232 systems.
- Request lot-specific RoHS compliance records when sourcing discontinued DRT1-232C2 units to ensure regulatory conformity.