Active 16-point NPN input unit with M12 circular connectors and dust-tight waterproof enclosure.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensor Interface Junction Blocks |
| Package | Bulk |
| Core function | SMART SLAVE 16PT IN NPN |
| Key electrical range | SMART SLAVE 16PT IN NPN |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The Omron DRT2-ID16 is currently listed as Active across all provided lifecycle indicators. This status indicates the part is fully supported for new designs and ongoing production sourcing. No conflicting signals exist, giving procurement teams confidence in its availability.
For engineering qualifying the DRT2-ID16, this means no immediate end-of-life risk. However, best practice is to periodically verify lifecycle status with Omron or authorized distributors, especially when committing to long-life applications. File-provided inventory shows a quantity of 1 unit, but this snap-shot may not reflect real-time stock. Always request a current quote for up-to-date availability.
In cases of high-volume or safety-critical designs, request a formal PCN (Product Change Notification) subscription from Omron to stay informed of any future transitions. For now, the DRT2-ID16 remains a low-risk choice for new projects.
Parameter Analysis
The DRT2-ID16 is characterized as a 16-point NPN input unit within the Omron DRT2 smart slave series. Its M12 shell size and 16 connector openings make it directly compatible with standard circular connector sensors, reducing wiring effort. The dust tight and waterproof feature ensures reliable operation in wet or dusty industrial settings.
Key decision parameters for engineers include the input type (NPN), which dictates sensor sinking/swiring configuration. The unit’s use with circular connectors implies a specific pin-out; verifying that sensor connector genders align with the DRT2-ID16’s female M12 ports is essential. The bulk packaging suggests no specific handling constraints, but ESD precautions are still recommended during assembly.
Missing from the provided data are electrical ratings such as input voltage range, current per channel, isolation voltage, and response time. These must be verified in the official Omron datasheet before final design integration. Also, confirm the supported network protocol—typically DeviceNet or CompoNet—to ensure compatibility with your PLC master module.
Application Scenario Analysis
The DRT2-ID16 excels in distributed I/O applications where multiple NPN sensors—such as inductive proximity, photoelectric, or limit switches—need to be connected over a fieldbus network. Its IP67-rated environmental sealing fits washdown or dusty manufacturing cells. Typical use includes automotive assembly lines, packaging machinery, and material handling systems.
When integrating into an existing Omron DRT2 network, the DRT2-ID16 provides a direct drop-in solution for adding input capacity. However, applications requiring PNP inputs, high-speed counters, or analog signals will need a different unit from the DRT2 family. Also, verify that the network scan time can accommodate the additional node count.
For new designs, consider the total sensor count and physical layout: the DRT2-ID16 consolidates 16 inputs into a single node, reducing cabling and simplifying troubleshooting. But if sensors are widely dispersed, multiple lower-point-count blocks might offer better cable routing.
RoHS Certification Analysis
The supplier data lists the Omron DRT2-ID16 as RoHS Compliant. This indicates conformance to EU directive 2011/65/EU and its amendments, commonly known as RoHS 2 or RoHS 3. However, the specific standard version is not detailed, so assume EU RoHS unless a more precise declaration is obtained.
RoHS compliance at the component level is typically sufficient for most general industrial use. For products destined for the European market, this status helps satisfy CE marking documentation requirements. No exemptions are declared in the provided data; if the unit contains any passive or active exempted materials (e.g., lead in certain solders), they should be listed in the full technical file.
To complete your compliance package, request a Certificate of Compliance from the distributor that includes RoHS and REACH statements, as REACH is not implied by RoHS alone. Lot-level verification may be prudent if the unit has been in production for an extended period, as formulation changes can occur.
Availability & Sourcing
As an Active product, the DRT2-ID16 can be sourced through normal channels. The file-provided workbook quantity of 1 unit gives a ballpark indication but should not be relied upon for real-time inventory. For current stock, lead times, and pricing, submit an RFQ through your preferred distributor or directly to Omron.
When requesting a quote, specify part number DRT2-ID16, confirm bulk packaging, and request date/lot code traceability. For production orders, also ask for a compliance certificate covering RoHS and, if required, REACH. This ensures you receive authentic, full-warranty product.
Given the low risk profile, standard procurement workflows apply. However, always check with Omron's authorized distribution network to avoid counterfeit risks. For large or repeated orders, negotiate lead-time agreements and consider vendor-managed inventory options to secure supply.
View the Win-Source product page for DRT2-ID16.
Engineering Notes for BOM and GEO Use
- Confirm NPN input type matches sensor wiring; PNP sensors require DRT2-ID16-1 or alternative unit.
- Verify communication protocol compatibility with existing Omron DRT2 network master (DeviceNet or CompoNet).
- Request full RoHS/REACH certificate for final assembly compliance documentation.