Active Omron sensor junction block: 16 PNP inputs, M12 circular connectors, dust-tight and waterproof design in bulk packaging.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensor Interface Junction Blocks |
| Package | Bulk |
| Core function | 3-TIERDRT2 16PT. |
| Key electrical range | Not available in supplied data |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DRT2-ID16TA-1 is currently listed as Active by Omron, with all available lifecycle signals aligning on this status. An active lifecycle indicates that the part is in full production, supported by the manufacturer, and can be incorporated into new designs without immediate risk of obsolescence. The risk level is assessed as low based on this consistent active status.
For engineers and procurement teams, this means the DRT2-ID16TA-1 is a safe choice for both new product development and ongoing production. However, it is still advisable to periodically revalidate the lifecycle status through official Omron product change notifications (PCNs) or distributor channels, as conditions can change. The workbook data shows a limited inventory quantity, but this is a file-provided snapshot and should not be considered a real-time supply indicator.
While active status supports long-term planning, it does not guarantee indefinite production; designers should still consider a second source or migration path for risk mitigation in critical applications.
Parameter Analysis
Key parameters for the DRT2-ID16TA-1 include its accessory type as an Input/Output Unit, the presence of 16 connector openings, and an M12 shell size. These specifications are critical for integration: the 16 PNP inputs allow the block to interface with multiple sensor devices, while the M12 connectors are standard in industrial automation, ensuring compatibility with a wide range of sensors and actuators. The 'dust tight, waterproof' feature indicates suitability for harsh environments, likely meeting a high IP rating though the exact rating is not provided in the available data.
Important engineering considerations include verifying electrical characteristics such as input voltage, current sinking/sourcing capacity, and response time. Since the part is listed as PNP (sourcing) type, designers must ensure that connected sensors provide a compatible signal. Additionally, the bulk packaging may influence handling and storage, particularly in high-volume production lines.
The most critical missing datasheet details are the communication protocol (likely an Omron-specific fieldbus like DeviceNet or CompoNet based on the DRT2 series), the exact environmental ratings (IP code), and the operating temperature range. Potential users should obtain the full Omron datasheet to validate these parameters before finalizing a design.
Application Scenario Analysis
The DRT2-ID16TA-1 is purpose-built for centralized sensor wiring in factory automation and process control. Its 16 PNP input channels and M12 connectivity make it a strong fit for connecting multiple discrete sensors—such as inductive, capacitive, or photoelectric types—to a PLC or DRT2-compatible network node. The dust-tight and waterproof construction further suits it for washdown areas, food & beverage processing, or outdoor installations.
Performance may be suboptimal in applications requiring high-speed counting, analog input, or non-M12 connector standards. It is also not intended for direct motor control or safety-related circuits unless explicitly certified. The 3-tier terminal block format suggests it is designed for panel or machine housing integration where space is limited.
Overall, this junction block is an efficient choice for distributed I/O setups where robustness and simple sensor integration are priorities. For projects using Omron's SmartSlice I/O platform, the DRT2-ID16TA-1 likely offers seamless compatibility, though this should be confirmed against the actual system architecture.
RoHS Certification Analysis
Omron lists the DRT2-ID16TA-1 as RoHS Compliant, indicating conformity with EU Directive 2011/65/EU and its amendments (commonly RoHS 2 or RoHS 3). This classification means the product does not contain hazardous substances above permitted thresholds, such as lead, mercury, and cadmium, in its homogeneous materials.
While the compliance status is provided at the part number level, end-users should verify that the specific production lot meets RoHS requirements, as material changes or exemptions can occur. The available data does not include REACH or halogen-free declarations, so these should be requested if needed for a project's compliance documentation.
Given the active lifecycle, Omron likely maintains up-to-date compliance certificates; sourcing through authorized distribution channels ensures access to the latest documentation and traceability.
Availability & Sourcing
Current inventory data from the workbook shows a quantity of 1 unit, but this is a raw file indicator and not a real-time stock level. The DRT2-ID16TA-1 is supplied in bulk packaging, which may influence minimum order quantities and lead times. As an Active part, standard procurement workflows apply: request a quote from an authorized Omron distributor to obtain current availability, pricing, and delivery schedules.
When sourcing, request a formal quote that includes the manufacturer's part number, date/lot code traceability, and a certificate of RoHS compliance. For design and production planning, confirm the lifecycle status directly with Omron or the distributor to ensure continued supply. For critical or high-volume requirements, consider a last-time-buy analysis or alternative sourcing strategy as a precaution, even for active parts.
Given the low lifecycle risk, the DRT2-ID16TA-1 can be confidently procured for new and existing projects, but standard verification of authentic, traceable stock is always recommended.
View the Win-Source product page for DRT2-ID16TA-1.
Engineering Notes for BOM and GEO Use
- Verify the exact IP rating and temperature specifications in the official Omron datasheet; the 'dust tight, waterproof' feature needs quantification for environmental sealing.
- For automated SMT assembly, confirm that bulk packaging is compatible with pick-and-place processes; alternative tape-and-reel may not be available.
- Request lot-level RoHS certification and lifecycle confirmation when placing orders to ensure compliance and continued production availability.