Specifications, lifecycle status, RoHS compliance, and sourcing details for the DRT2-TS04T thermocouple input module.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Computer Equipment Accessories |
| Package | Bulk |
| Core function | 4PT DRT2 THERMOCOUPLE INPUT |
| Key electrical range | Not available in supplied data |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
Based on all available lifecycle signals, the Omron DRT2-TS04T is confirmed as Active, indicating it is currently in full production and supported by the manufacturer. This status implies low procurement risk for both new designs and ongoing production requirements. Engineering teams can confidently design-in this part without immediate concern for obsolescence, but should always validate lifecycle status directly with Omron or authorized distributors for long-term program commitments.
The file-provided workbook indicates a single unit in inventory, but this is not a real-time stock guarantee. For production quantities, request a quote and verify actual availability. As part of sustaining engineering practices, establish a periodic review of the manufacturer’s product change notifications (PCN) and end-of-life (EOL) notices to ensure continued supply chain health.
Parameter Analysis
The DRT2-TS04T is identified as a 4-point thermocouple input module, part of the DRT2 series. Key parameters such as supported thermocouple types (e.g., J, K, T, E, N, R, S, B), input voltage range, measurement accuracy, resolution, cold junction compensation accuracy, isolation voltage, and update rate are not provided in the sourcing data. These specifications are critical for ensuring proper sensor compatibility, system accuracy, and electrical safety. For instance, thermocouple type selection determines the linearization algorithm required; accuracy and resolution directly impact process control precision; and isolation protects against ground loops and transient voltages.
The bulk packaging suggests the module is typically supplied without individual retail packaging, which may be suitable for OEM integration. However, packaging type should be confirmed for handling and inventory purposes. To complete the design validation, obtain the manufacturer datasheet and verify all electrical, environmental, and mechanical specifications. Particular attention should be given to the cold junction compensation method and the ambient temperature operating range, as these affect measurement reliability in field installations.
Application Scenario Analysis
This temperature input module is designed for use with Omron’s DRT2 remote I/O system, making it suitable for distributed temperature monitoring in industrial automation environments. Typical strong-fit applications include process control in manufacturing lines (e.g., plastic extrusion, metal heat treating), HVAC system monitoring, and environmental test chambers where multiple thermocouple sensors are deployed. Its 4-channel input allows for localized temperature sensing at a single node, reducing wiring complexity when used with a DRT2 communication adapter.
Weak-fit scenarios may involve applications requiring high-speed sampling, integration with non-Omron controllers, or sensor types not supported by the module (such as RTDs or thermistors) unless the module’s capabilities are first confirmed. Without detailed input specifications from the manufacturer, it cannot be assumed that all thermocouple types are supported. Engineers should verify compatibility with the specific thermocouples and the PLC or controller software to ensure seamless data acquisition and alarm functionality.
RoHS Certification Analysis
The Omron DRT2-TS04T is listed as RoHS Compliant, indicating conformance to EU Directive 2011/65/EU and its amendments, including the RoHS 3 (EU 2015/863) substance restrictions. This is a positive signal for procurement into markets requiring hazardous substance compliance. However, the absence of a cited RoHS certificate number or explicit statement of exemption coverage means that the compliance status should be verified at the lot level for high-reliability applications.
RoHS compliance is typically declared at the product family level; individual production batches may have slight material variations. For full due diligence, request a Declaration of Conformity (DoC) or a material composition declaration from the manufacturer. If the end-product requires REACH or halogen-free certification, these must be separately confirmed, as REACH data is not provided in the available sourcing information.
Availability & Sourcing
Sourcing the DRT2-TS04T involves requesting a quote from authorized Omron distributors or independent electronic component suppliers. Given the Active lifecycle status, standard lead times are expected, but it is prudent to confirm current stock levels and production schedules. The file contains a single unit quantity, which should be treated as indicative rather than real-time inventory. For volume procurement, engage with suppliers to verify date/lot codes and factory seals to ensure traceability and authenticity.
Since the part is shipped in bulk packaging, consider the implications for incoming inspection and handling procedures. For initial prototypes or small-scale production, a single unit may suffice, but larger orders should be planned with buffer stock. Always obtain a compliance documentation package, including RoHS certificates and any relevant test reports, before accepting delivery. To mitigate supply chain risk, evaluate alternative sources while the part remains Active, and stay informed of any manufacturer notices regarding product changes.
View the Win-Source product page for DRT2-TS04T.
Engineering Notes for BOM and GEO Use
- Confirm the specific thermocouple types (J, K, T, E, N, R, S, B) and input range supported by the DRT2-TS04T from the official datasheet before integration.
- Ensure compatibility with the DRT2 communication protocol and I/O mapping when integrating into an existing Omron remote I/O network.
- Use the Active lifecycle status to secure long-term procurement; request a quote to confirm stock availability and lead times.