Active IP67 Smart Slave with 16 connector openings, M12 shell, and RoHS compliance.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensor Interface Junction Blocks |
| Package | Bulk |
| Core function | SMART SLAVE IP67 8 OUT 2 OUT |
| Key electrical range | SMART SLAVE IP67 8 OUT 2 OUT |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The Omron DRT2-WD16CL-1 is currently classified as Active, indicating full manufacturer support and continued production. This status means the part is suitable for new designs and is readily available for procurement through authorized channels. Engineers can proceed with this junction block in new projects with confidence that design support and supply continuity are expected.
Given the consistent Active signals from all supplied sources, there is no indicated lifecycle conflict or ambiguity. However, for long-lifecycle industrial designs, it is prudent to request a formal lifecycle notification commitment from Omron or verify end-of-life policy timelines directly with the manufacturer.
While the workbook inventory shows zero units at the time of file creation, this is a file-based snapshot and not a guarantee of real-time stock. Buyers should query current availability and lead times through a request-for-quote process to ensure supply before ordering. No procurement risks are currently flagged for this Active component.
Parameter Analysis
The DRT2-WD16CL-1 is specified as an Input, Output Unit accessory with 16 connector openings, an M12 shell size, and IP67 dust-tight and waterproof construction. These parameters are central to its function as a sensor interface junction block: the 16 openings allow distribution of multiple sensor or actuator signals, while the M12 shell size is compatible with standard industrial circular connectors, simplifying integration into existing cable assemblies.
The IP67 rating certifies protection against dust ingress and temporary immersion in water, making the unit suitable for washdown areas and harsh industrial environments. The bulk packaging format implies standard industrial shipment, but actual box quantity and protection should be confirmed during procurement.
Key parameters not provided in the source data include input/output voltage and current ratings, signal type compatibility (e.g., digital/analog, PNP/NPN), and communication protocol. These are critical for ensuring the block interfaces correctly with the intended control system. Engineers must consult the official Omron DRT2 series datasheet and user manual to validate electrical specifications and connectivity before design-in.
Application Scenario Analysis
The Omron DRT2-WD16CL-1 sensor interface junction block is well-suited for distributed I/O applications in industrial automation, particularly where multiple sensors or actuators need to be connected in a space-constrained, dust- and water-exposed location. Typical strong-fit scenarios include conveyor systems, packaging machinery, and factory floor sensor arrays where IP67-rated enclosures are required.
Its 16 connector openings and M12 circular connector compatibility make it a natural fit for modular machine designs that use quick-connect cabling for rapid installation and maintenance. The dust-tight and waterproof features support use in food & beverage processing areas subject to washdown, provided the chemical resistance of materials is verified.
Weak-fit scenarios might include very high-vibration or extreme temperature environments not addressed in the current specification snapshot, or applications requiring specific electrical isolation or surge protection not detailed here. Without further electrical characterisation, use in mixed-signal or safety-critical circuits should be validated against Omron's design guidelines to avoid integration surprises.
RoHS Certification Analysis
The DRT2-WD16CL-1 is declared RoHS Compliant based on the status field provided. This classification generally indicates conformity with the European Union's Restriction of Hazardous Substances directive, likely the current RoHS 3 (EU 2015/863) which restricts substances such as lead, mercury, cadmium, and certain flame retardants. The compliance is critical for products sold or used within the EU market.
Since no specific exemption or certification document is included in the source data, compliance is assumed to be at the component level. For high-volume production or export compliance, buyers should request a formal RoHS certificate or declaration from Omron or an authorized distributor, ensuring the compliance traceability is valid for the specific date or lot code of the purchased components.
Note that RoHS status is typically a self-declaration by the manufacturer. For applications requiring REACH, conflict minerals, or other environmental compliance, additional documentation should be separately requested, as REACH compliance is not a substitute for RoHS.
Availability & Sourcing
The Omron DRT2-WD16CL-1 is an Active product, which generally implies good channel availability. The workbook inventory indicates zero units on hand at the file generation time; however, this is a static snapshot and actual distributor stock may differ. Buyers are advised to request a live quote through an authorized sourcing platform to obtain up-to-date pricing, lead times, and availability.
Sourcing from authorized distribution ensures traceability, date/lot code verification, and access to manufacturer compliance certificates. The unit is supplied in bulk packaging, and minimum order quantities should be clarified. Since the lifecycle is Active, no immediate end-of-life risk exists, but long-term supply agreements or scheduled orders can be considered for production stability.
For compliance verification, request the RoHS certificate and confirm the IP67 rating through documentation. When the part is used in new designs, early engineering samples can be procured to validate mechanical fit with M12 circular connectors and electrical performance in the target system.
View the Win-Source product page for DRT2-WD16CL-1.
Engineering Notes for BOM and GEO Use
- Validate all electrical parameters (voltage, current, communication protocol) through the official Omron DRT2-WD16CL-1 datasheet before design integration.
- For industrial environments requiring dust and water protection, confirm that the IP67 rating meets specific washdown or immersion requirements beyond the standard test.
- Since file quantity is zero, initiate a request for quote early to assess lead time and ensure alignment with project schedules.