Sensata-Crydom DRTA06D06 Solid State Time Delay Relay – On-Delay, 6 A, 48 VDC, DIN Rail
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Time Delay Relays |
| Package | Bulk |
| Core function | RELAY TIME DELAY 6A 48V DIN RAIL |
| Key electrical range | Contact Rating @ Voltage: 6A @ 48VDC; Supply and Demand Status: Shortage; Voltage - Supply: 12 ~ 24VAC/DC |
| Workbook inventory signal | 15 pcs listed in the provided file |
Lifecycle Analysis
The DRTA06D06 from Sensata-Crydom is currently listed as Active with a low risk level, and all provided lifecycle signals align with no detected conflicts. An Active status typically indicates that the part is in full production and recommended for new designs without imminent end‑of‑life concerns. However, procurement should note that a shortage condition has been tagged for this device, which suggests that lead‑time fluctuations or constrained allocation may occur even though the lifecycle remains favourable.
For engineering teams, this means the DRTA06D06 can be confidently selected for new projects, but a buffer stock strategy or early ordering schedule is prudent. Sustaining production environments should revalidate the lifecycle status at the supplier level, especially if the design has a long projected lifetime, to ensure that no silent transition to NRND occurs.
If the device is used in safety‑critical or high‑volume builds, contacting Sensata-Crydom directly for a product road map and minimum order quantity confirmation is recommended. The Active classification alone does not eliminate the need for periodic lifecycle monitoring, particularly when inventory signals point to a supply/demand imbalance.
Parameter Analysis
The DRTA06D06 delivers a solid‑state on‑delay timing function with an SPST‑NO (1 Form A) contact rated at 6 A and 48 VDC. Supply voltage range spans 12 to 24 VAC/DC, making it compatible with common industrial control circuits. These parameters are critical for load rating margins, coil power budgeting, and PCB‑free DIN‑rail integration.
For derating analysis, engineers should examine the 6 A contact rating against inrush or inductive load characteristics; solid‑state outputs can be sensitive to over‑voltage transients, so snubbing may be required. The supply voltage range indicates broad‑application flexibility, but the simultaneous AC/DC capability needs confirmation of the internal power supply topology from the datasheet, particularly for brownout immunity and no‑load quiescent current.
Key missing items from the provided specification set include the adjustable timing range (e.g., seconds, minutes), timing accuracy, repeatability, and ambient temperature limits. These values directly influence reliability and must be verified before final qualification. Other layout‑relevant details such as isolation voltage, dielectric strength, and UL/cUL recognition also require datasheet consultation.
Application Scenario Analysis
The DRTA06D06 is a strong fit for industrial automation tasks where a solid‑state on‑delay relay reduces mechanical wear and switch‑noise. Typical deployments include delayed start of small motors or pumps, lamp warm‑up sequencing, conveyor belt start‑up staggering, and control panel signalling where a DIN‑rail footprint simplifies installation.
Because the contact rating is 6 A at 48 VDC, applications driving higher DC loads (e.g., solenoid valves with high inrush) may require current‑limiting measures or a larger‑rated relay, making this part a weaker fit for heavy‑duty actuation without additional contactor stage. Similarly, if the timing precision must be within milliseconds over a wide temperature range, the device’s screwdriver‑slot adjustment offers limited granularity and may be unsuitable for high‑accuracy HVAC or laboratory instruments.
Its solid‑state nature also makes it attractive in noise‑sensitive or vibration‑prone environments, but the absence of an integrated heat sink might restrict usage in thermally challenged enclosures. Engineers should cross‑reference the datasheet for maximum ambient operating temperature and derating curves when assessing fit for sealed outdoor cabinets or high‑density panel layouts.
RoHS Certification Analysis
The DRTA06D06 is listed as RoHS Compliant, which generally means the product meets the European Union’s Restriction of Hazardous Substances Directive. This compliance is essential for products sold in EU markets and many global OEM supply chains. Without a specific standard version in the source data, it is prudent to confirm compliance against RoHS 3 (Directive 2015/863) for the latest four‑phthalate scope.
Solid‑state relays often contain semiconductor dies, plastic encapsulants, and lead‑frame materials; the lack of explicit exemption notes suggests the manufacturer has achieved full material compliance. However, RoHS status can apply at a family level, and lot‑to‑lot variation in subcontractor processes may exist. Buyers should request a certificate of compliance tied to the purchase lot and, if applicable, verify REACH SVHC status separately—REACH compliance is not a substitute for RoHS.
For high‑reliability sectors such as medical or aerospace, where traceability is paramount, consider asking for a full material declaration (FMD) from Sensata‑Crydom to close out any regulatory risk in early design reviews.
Availability & Sourcing
Sourcing the DRTA06D06 requires attention to two concurrent signals: an Active lifecycle and a supply‑and‑demand status marked as Shortage. A file‑provided inventory quantity of 15 units is noted, but this figure is not a real‑time guarantee and should be validated through a formal quote request.
As an Active part, the standard sourcing workflow involves issuing an RFQ to authorized Sensata‑Crydom distributors, confirming available stock, lead time, and traceability features such as date/lot code. Given the shortage flag, buyers are encouraged to secure inventory early and evaluate whether a safety stock level can be negotiated on long‑term contracts. Packaging is bulk, and termination is via screw terminals, so ensure that any kitting requirements for automated assembly are addressed upfront.
For production qualification, request a manufacturer’s certificate of conformance and RoHS compliance documentation for the specific lot. This step is particularly important when integrating the DRTA06D06 into designs that must pass regulatory audits. Where supply tightness persists, consider engaging the manufacturer’s field application engineers to discuss alternative timing‑adjustment variants or buffer strategies without redesigning the BOM.
View the Win-Source product page for DRTA06D06.
Engineering Notes for BOM and GEO Use
- The short supply status requires early engagement with distributors and consideration of alternative lead‑time windows when designing in DRTA06D06.
- Always cross‑check the exact timing range and adjustment resolution directly in the manufacturer datasheet, as these are not fully detailed in provided data.
- Request lot‑specific RoHS compliance certificates and consider verifying MSL / packaging conditions if the relay will be stored before assembly.