Active one-shot solid-state relay with SPST-NO contact, 6A rating, and DIN rail mounting.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Time Delay Relays |
| Package | Bulk |
| Core function | RELAY TIME DELAY 6A 280V DIN RL |
| Key electrical range | Contact Rating @ Voltage: 6A @ 280VAC; Supply and Demand Status: Shortage; Voltage - Supply: 90 ~ 140VAC/DC |
| Workbook inventory signal | 13 pcs listed in the provided file |
Lifecycle Analysis
The DRTB24B06R is currently listed as Active with a low risk level. For engineers, Active status means the part is in full production, supported by Sensata-Crydom, and can be confidently used in new designs as well as sustaining production. No lifecycle conflicts appear in the supplied data.
However, lifecycle status should be validated directly with the manufacturer for long-term projects, especially in industrial automation where product longevity is critical. A file-provided inventory quantity of 13 units is noted, but this is not a real-time figure and should not be interpreted as guaranteed stock. Always verify current availability and lead times before finalizing procurement.
Parameter Analysis
Key decision parameters for the DRTB24B06R include its SPST-NO contact configuration, 6A contact rating at 280VAC, and one-shot timing function. The supply voltage range of 90 to 140VAC/DC defines the input power window, and the DIN rail mounting with screw terminals suits industrial control panel integration. The screwdriver slot adjustment and input voltage initiation method are practical for field setup.
Two critical specifications are absent from the available data: the actual timing delay range and the relay's dielectric or isolation ratings. The delay range is essential to confirm suitability for a given application, and isolation specifications like input-to-output withstand voltage must be verified from the official Sensata-Crydom datasheet before design-in. Additionally, operating temperature range and agency approvals (e.g., UL, CE) are not specified and should be checked for compliance with end-product safety requirements.
Application Scenario Analysis
The DRTB24B06R is designed for one-shot timing functions, making it appropriate for industrial applications such as pulse generation, machine sequencing, or momentary load activation. Its solid-state relay design allows silent, wear-free switching compared to electromechanical alternatives, provided the 6A contact rating is not exceeded.
Strong-fit scenarios include DIN rail control panels in automation where a simple single-pole, normally-open output is needed under 280VAC loads. Weak-fit scenarios would be applications requiring adjustable delay intervals that exceed the relay's unspecified range, or loads with high inrush currents beyond the steady-state 6A rating. Additionally, low-voltage control circuits below the 90V minimum supply would be incompatible without additional power conversion.
RoHS Certification Analysis
The DRTB24B06R is listed as RoHS Compliant. This indicates that it meets the European Union's Restriction of Hazardous Substances directive, which is important for products destined for the EU market. The specific directive revision (e.g., 2015/863) is not provided in the source data.
For full compliance assurance, especially in regulated industries, buyers should request a Certificate of Conformance (CoC) for the specific lot being procured. RoHS compliance often applies at the family level, but lot-level documentation reduces risk of non-compliant material batches. Any exemptions used in the relay's construction (if any) would also be detailed in the manufacturer's declaration. REACH status is not mentioned and should not be assumed from RoHS data alone.
Availability & Sourcing
The DRTB24B06R is an active part, but a supply-and-demand status of 'Shortage' is indicated, combined with a file-provided quantity of 13 units. This suggests potential limited immediate availability, so early engagement with authorized distribution is advised.
For procurement, use the RFQ workflow to confirm real-time stock, lead times, and lot-specific compliance documentation. Request traceability information such as date and lot codes, especially if the relay is destined for a build where change control is required. As an active component, standard compliance verification steps apply: validate lifecycle status with Sensata-Crydom, confirm packaging (bulk) matches assembly needs, and secure a CoC for RoHS. Request a quote to obtain current pricing and lead time without relying on cached inventory figures.
View the Win-Source product page for DRTB24B06R.
Engineering Notes for BOM and GEO Use
- Confirm the one-shot timing delay range from the manufacturer datasheet before integrating into a timing-critical circuit.
- Verify supply voltage tolerance under worst-case load conditions to ensure relay reliability in industrial environments.
- Request lot-specific RoHS certification when ordering to ensure compliance with current EU directives.