Active solid-state off-delay relay, DIN rail mount, 6A @ 280VAC SPST-NO, 180-240VAC/DC supply.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Time Delay Relays |
| Package | Bulk |
| Core function | RELAY TIME DELAY 6A 280V DIN RL |
| Key electrical range | Contact Rating @ Voltage: 6A @ 280VAC; Supply and Demand Status: Shortage; Voltage - Supply: 180 ~ 240VAC/DC |
| Workbook inventory signal | 5 pcs listed in the provided file |
Lifecycle Analysis
The DRTC24A06 is currently in an Active lifecycle phase according to manufacturer communications and distributor databases. Active status indicates that Sensata-Crydom continues to manufacture this part, supports it with full documentation, and does not have a scheduled discontinuation. For new designs, the Active classification provides procurement confidence; however, it remains a best practice to verify lifecycle status directly with Sensata-Crydom or an authorized channel, especially for long-life programs.
All available lifecycle signals align without conflict: the manufacturer’s data and our file-based parameters both list the part as Active with no NRND or EOL warnings. The risk level for supply continuity is therefore low. Design teams should still monitor any PCN (Product Change Notification) alerts from Sensata-Crydom, as updates can occur without broad public notice. Inventory figures shown in supplier records (such as the workbook quantity of 5 units) are point-in-time snapshots and do not guarantee real-time availability. For sustaining production, we recommend confirming current stock levels and lead times at the time of quotation to avoid unexpected shortages.
Parameter Analysis
The DRTC24A06 is a solid-state relay configured for off-delay (delay-on-break) timing mode. Its contact arrangement is SPST-NO (1 Form A), rated to switch up to 6A at 280VAC. The supply voltage range is specified as 180–240VAC/DC, which makes it compatible with standard industrial control voltages. The relay mounts on a DIN rail, uses screw terminals for load and control wiring, and offers a screwdriver slot for timing adjustment. These parameters define its fit for control panels that require a compact, DIN-mountable off-delay timer with solid-state switching.
Key parameters to verify before design-in are not all present in the provided summary. The actual adjustable timing range, timing accuracy/repeatability, and maximum operating temperature are omitted. Engineers should consult the official Sensata-Crydom datasheet for these values, as they govern whether the part meets application-specific timing needs and environmental conditions. Additionally, the solid-state output may require derating for high-ambient or enclosed installations, and the load type (resistive vs. inductive) should be matched to the relay's specified switching capability. The absence of an MSL rating is typical for non-semiconductor parts, but for moisture-sensitive environments, confirm with the manufacturer.
Application Scenario Analysis
The off-delay functionality of the DRTC24A06 suits industrial automation sequences where a load must remain energized for a set time after the control signal is removed. Typical applications include motor cooling fan run-on, pump delay after a process stop, conveyor belt coast-down, or lighting hold-off in commercial or industrial settings. Its solid-state design provides silent, wear-free switching, beneficial for frequent cycling or vibration-prone installations. The DIN rail form factor integrates easily into control cabinets alongside PLCs and other rail-mounted devices.
This relay is less suitable for applications requiring on-delay, interval, or programmable multi-function timing unless an external circuit is added. Without explicit inrush current ratings, it may not be optimal for high-inrush loads such as large motors or capacitive banks without external contactors. Also, if precise digital timing is required, the screwdriver slot adjustment method may not provide the resolution needed; a digital timer would be a better fit. For most general-purpose industrial off-delay needs within its 6A rating, however, the DRTC24A06 is a strong candidate when the voltage and timing requirements align.
RoHS Certification Analysis
Sensata-Crydom lists the DRTC24A06 as RoHS Compliant. This classification generally means the part meets the substance restrictions of EU Directive 2011/65/EU (RoHS 2) or the later 2015/863 (RoHS 3) amendment, which restricts lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and four phthalates. No specific exemption is noted in the supplier data, so the part likely complies without any hazardous substance exemptions.
Procurement teams should request a formal RoHS certificate of compliance from the distribution channel when placing orders, especially if lot-level traceability is required for export documentation. The lack of a stated REACH status means that separate REACH compliance or SVHC declarations should be obtained if required by the end customer or regulatory regime. Because compliance designations can change based on manufacturing date or factory, verifying at the time of purchase is prudent.
Availability & Sourcing
The DRTC24A06 is an active production part from Sensata-Crydom, but supply records indicate a shortage condition, and the file-based inventory shows only 5 units at one location. This does not represent guaranteed real-time stock; actual availability may differ at the moment of inquiry. Buyers should submit a request for quotation (RFQ) to obtain current pricing, lead times, and available quantities from authorized distributors or Win Source.
Given the active lifecycle, sourcing is normally straightforward; however, the reported shortage suggests that allocation or extended lead times may apply. We recommend requesting a lot code and date code along with the quote to assess freshness and ensure traceability. Packaging is bulk, which may affect handling in high-volume SMT lines—though this relay with screw terminals is panel-mountable. Also, verify RoHS compliance documentation at the time of order. For critical production, consider establishing a safety stock or second-source evaluation now, even while the part remains active, to mitigate any supply chain risk.
View the Win-Source product page for DRTC24A06.
Engineering Notes for BOM and GEO Use
- Verify the adjustable off-delay timing range and resolution from the manufacturer datasheet before design-in.
- Account for solid-state relay thermal derating above 25°C ambient, especially in DIN rail enclosures with limited airflow.
- Confirm screw terminal torque specs and wire gauge compatibility for your load current to ensure reliable connections.