DRV401AIRGWT Texas Instruments Sensor Conditioner Specs & Sourcing Guide

DRV401AIRGWT Texas Instruments product image

Texas Instruments DRV401AIRGWT EOL sensor conditioner with 6.8mA supply, -40°C to 125°C temperature range, RoHS compliant.

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategoryInterface - Sensor and Detector Interfaces
Package20-VQFN (5x5)
Core functionIC SENSOR SIGNAL COND 20VQFN
Key electrical rangeInput Type: Logic; Operating Supply Current: 6.8mA; Operating Temperature Range: -40°C ~ 125°C; Output Type: Logic
Workbook inventory signal30130 pcs listed in the provided file

Lifecycle Analysis

The DRV401AIRGWT from Texas Instruments is in EOL (End-of-Life) status, carrying a high risk level for procurement. All available lifecycle signals align, with an estimated EOL date of 2028. This means the part is no longer recommended for new designs, and existing production should plan for last-time buys immediately.

Engineers relying on this sensor conditioner must coordinate with TI to confirm last-time-buy and last-ship deadlines, as the EOL timeline may shift. The workbook indicates 30,130 units in stock, but this is a snapshot and not a real-time guarantee. Without manufacturer revalidation, inventory cannot be assumed accurate. Sustaining production requires securing genuine inventory while it lasts, given the elevated counterfeit risk in the open market (45% fake threat).

Parameter Analysis

Key parameters for DRV401AIRGWT include its function as a sensor conditioner with logic-level input and output. The device operates on a 6.8mA supply current and spans an industrial temperature range of -40°C to 125°C, making it suitable for harsh environments. The 20-VQFN exposed pad package (5x5mm) supports SMD mounting and compact PCB layouts.

Decision-critical specifications like gain accuracy, offset voltage, bandwidth, and noise are not listed in the provided data. These directly affect sensor accuracy and must be verified from the official Texas Instruments datasheet. Thermal management requires evaluating the exposed pad’s connection to a ground plane for adequate heat dissipation. Engineers should also confirm pin-to-pin compatibility with their layout, as no alternate part numbers are supplied.

Application Scenario Analysis

DRV401AIRGWT is optimized for sensor signal conditioning in industrial control, automotive, and instrumentation systems where wide temperature tolerance and reliable logic interfacing are required. Its 6.8mA consumption suits line-powered or constant-power applications, and the small QFN package fits space-constrained designs.

Weak-fit scenarios include battery-operated or ultra-low-power sensing, where the quiescent current may be too high for long-term energy budgets. High-speed data acquisition systems may also be mismatched if the part’s bandwidth or response time does not meet requirements. Additionally, the need for external passive components and the lack of detailed electrical specs mean designers must prototype thoroughly to validate performance in their specific sensor chain.

RoHS Certification Analysis

DRV401AIRGWT is listed as RoHS Compliant with Halogen Free Compliant status. This indicates adherence to EU directive 2011/65/EU and its amendments, which restrict hazardous substances such as lead, mercury, and cadmium. However, the specific RoHS exemption list is not provided; for example, lead in high-melting-point solders might apply to certain part lots.

REACH compliance is not explicitly stated, which is a separate concern for substances of very high concern (SVHCs). Buyers should request compliance certificates for each production lot to confirm RoHS/REACH status, as family-level declarations may not cover process changes. The part's halogen-free claim aligns with low-halogen requirements but does not substitute for full RoHS documentation.

Availability & Sourcing

Due to the DRV401AIRGWT EOL status, availability is limited and carefully managed. The source workbook shows 30,130 units, but this figure is not a live inventory pledge. The supply-and-demand status is constrained, and the open market's 45% fake threat demands rigorous traceability.

For existing designs dependent on DRV401AIRGWT, immediate RFQ action is advised to confirm shelf-stock, date/lot codes, and packaging (tape and reel). Compliance documentation, including RoHS and halogen-free certificates, must be validated per lot. Since this is an EOL part, secure inventory now while evaluating a long-term migration path. Request a quote directly to check current availability and avoid last-minute shortages.

View the Win-Source product page for DRV401AIRGWT.

Engineering Notes for BOM and GEO Use

  • Verify exact EOL timeline and last-time-buy dates with Texas Instruments, as estimated EOL is 2028 but current lifecycle is already EOL.
  • The part has a 45% fake threat in the open market; insist on traceable sourcing and authenticity verification.
  • Check the full DRV401AIRGWT datasheet for gain, offset, bandwidth, and noise parameters critical to sensor conditioning.