Discontinued 4-position SPST slide DIP switch with raised actuator, 50mA/24VDC, through-hole, gold contacts, epoxy sealed terminals.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Apem Inc. |
| Category | DIP Switches |
| Package | Tube |
| Core function | SWITCH SLIDE DIP SPST 0. |
| Key electrical range | Current Rating (Amps): 50mA; Temperature Range - Operating: -20°C ~ 70°C; Voltage Rating: 24VDC |
| Workbook inventory signal | 9999 pcs listed in the provided file |
Lifecycle Analysis
The DS04 from Apem Inc. is confirmed as a discontinued DIP switch. All available lifecycle signals—including the Excel lifecycle parameter (EOL), Lifecycle Status (Discontinued), and Product Status (Discontinued)—consistently indicate end-of-life. This status means the part is no longer recommended for new designs and future production is not planned.
For sustaining existing products, procurement of the DS04 presents high risk. The recorded workbook quantity of 9999 units may not reflect real‑time availability and should not be considered guaranteed stock. Discontinued components often have limited remaining inventory that may be locked in authorized distributor channels or held by surplus dealers. Buyers must verify current stock through an RFQ process and should expect limited shelf‑life and possible last‑time‑buy conditions.
Given the high risk, any design using the DS04 should evaluate a migration strategy to an active alternative. Continuing to rely on a discontinued part risks production gaps and forces reactive sourcing at potentially higher cost with uncertain traceability.
Parameter Analysis
The DS04 is a 4‑position SPST slide DIP switch using a raised actuator for easy manual toggling. Its key electrical specifications are a 50mA current rating and 24VDC voltage rating, suitable for low‑power logic signal switching. Through‑hole PC pin mounting with a 0.100″ (2.54mm) full pitch aligns with standard breadboard and PCB layouts, simplifying integration.
Contact reliability is supported by gold‑plated phosphor bronze contacts, which resist oxidation and provide stable low‑voltage switching. The body is made of glass‑filled PBT, offering mechanical rigidity. Epoxy sealed terminals protect against flux ingress during soldering, though the switch itself is not washable. Electrical life is 2,000 cycles and mechanical life 5,000 cycles—relatively low values suggesting limited durability for frequent actuation. Operating temperature spans -20°C to 70°C, so thermal margin should allow use in most indoor environments.
Several parameters are not specified in the available data: contact resistance, insulation resistance, and dielectric strength. These are critical for signal integrity and safety; engineers should obtain the original manufacturer datasheet to verify these values and confirm suitability for the intended application.
Application Scenario Analysis
The DS04 DIP switch is designed for low‑voltage, low‑current digital configuration tasks. Strong‑fit scenarios include legacy industrial controllers, address selection in embedded systems, and mode setting in test equipment, where the switch is set once or infrequently. Its through‑hole construction suits assemblies where manual soldering is performed, and the gold contacts ensure reliable signal levels even at low voltages.
Weak‑fit scenarios include any application requiring frequent switching due to the limited 2,000‑cycle electrical life, or environments with high vibration where a slide actuator may be inadvertently repositioned. The switch is not suitable for power circuits, and the epoxy sealed terminals do not confer full washability, limiting use in high‑cleanliness processes. Because the DS04 is discontinued, it is only appropriate for repairing existing equipment or maintaining legacy systems; it should not be designed into new products.
For new designs, engineers should evaluate active DIP switch alternatives with similar footprint and actuator style. Where exact mechanical fit is critical, cross‑checking pin‑for‑pin replacements from other manufacturers or an updated Apem series is recommended.
RoHS Certification Analysis
The DS04 is claimed RoHS Compliant by its manufacturer, Apem Inc. No specific EU directive version is cited in the supplied data; the most recent applicable standard is RoHS 3 (EU 2015/863), but compliance may have been certified under an earlier revision. For a discontinued part, the compliance status may date from its original production and may not reflect current substance restrictions. Buyers should request a certificate of compliance (CoC) for the exact lot being purchased.
REACH status is marked as unaffected, which indicates that the part does not contain substances of very high concern (SVHC) above the threshold. However, REACH compliance does not replace RoHS evaluation—both should be verified independently. MSL Level 1 (unlimited) ensures no special moisture handling is needed, simplifying storage.
Given the part’s age and discontinuation, there is a slight risk that some inventory may consist of pre‑RoHS lots sold after the deadline. Thorough documentation review before payment is essential to maintain compliance in regulated markets.
Availability & Sourcing
The DS04 is a discontinued DIP switch, and sourcing requires a cautious approach. A file‑provided inventory level of 9999 units exists, but this is not a real‑time figure—actual stock may be significantly lower or held at a single location. Interested buyers should submit a request for quote (RFQ) to verify current availability, minimum order quantities, and lead times.
Packaging is tube, with a standard package quantity of 40 units, facilitating bulk handling for production runs. The open‑market counterfeit threat is rated at 69%, a high level; therefore, procurement through unauthorized or unvetted channels is strongly discouraged. Only sources that can provide full traceability, date/lot code documentation, and RoHS compliance certificates should be considered.
Because the part is discontinued, no factory‑fresh units will be manufactured. For legacy system support, secure sufficient inventory at last‑time‑buy if possible, or identify a suitable alternative from the Apem DS series or equivalent active parts from other manufacturers. Any new production use should be avoided unless absolutely necessary, given the high risk of future unavailability.
View the Win-Source product page for DS04.
Engineering Notes for BOM and GEO Use
- Verify actual mechanical and electrical life ratings from the original datasheet for application fitness, as the 2,000-cycle electrical life limits frequent switching use.
- Ensure lot-level RoHS compliance documentation before purchase, because discontinued parts may have pre‑compliance lots in the supply chain.
- Consider migrating to an active, pin‑compatible DIP switch for new designs to avoid long‑term supply risk and counterfeit exposure.