Schurter Inc. Common Mode Choke – Verify Lifecycle & Secure Sourcing
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | Radial |
| Core function | CMC 630MA 2LN TH |
| Key electrical range | Current Rating (Max): 630mA; DC Resistance (DCR) (Max): 500mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 125°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The lifecycle status of Schurter Inc. part DS1-175-0002 is currently unknown. No official lifecycle signals, such as active, NRND, or EOL classifications, are available in the supplied data. This absence means that engineers and buyers cannot assume the part is in full production or recommended for new designs without further verification.
For new design projects, it is essential to contact Schurter Inc. or an authorized distributor to confirm the current production status. Relying on an unverified lifecycle can introduce supply chain risk, especially when planning long-term availability. For existing sustaining production, secure inventory while monitoring any manufacturer notices.
File-provided inventory data indicates only a single unit in stock, which is not a guarantee of real-time availability. Given the unknown lifecycle, conservative procurement practices should be applied. Verify manufacturer documentation, request a product change notification (PCN) if applicable, and evaluate alternative sources early in the design phase to mitigate risk.
Parameter Analysis
The DS1-175-0002 common mode choke offers a maximum current rating of 630 mA, which sets the upper limit for continuous operation without excessive heating. Designers should derate this value based on ambient temperature and PCB thermal conditions, especially given the wide -40°C to 125°C operating range. The maximum DC resistance of 500 mΩ per winding contributes to I²R losses and voltage drop, impacting efficiency in low-voltage circuits.
With a 600 V DC voltage rating, this choke provides substantial insulation for high-voltage DC bus filtering. Its 2-line through-hole radial package simplifies manual assembly and prototyping but requires careful PCB layout to minimize stray capacitance. The 17.5 mm x 16.0 mm footprint demands adequate board space, and the bulk packaging suits small-to-medium production runs.
Key missing parameters include nominal inductance, impedance vs. frequency, insulation resistance, and safety agency approvals. These are critical for impedance matching, EMI suppression performance, and regulatory compliance. Engineers must obtain the full datasheet to verify that actual inductance and attenuation meet system requirements before committing to this part.
Application Scenario Analysis
This 2-line common mode choke is suited for suppressing conducted electromagnetic interference on low-current DC power and signal lines. Its 630 mA rating makes it a strong candidate for applications such as industrial sensor interfaces, USB 2.0 power lines, CAN bus nodes, or RS-485 transceivers, where common-mode noise filtering is needed without high current demands.
The through-hole radial package is well-matched for prototyping, legacy equipment repair, or ruggedized designs that benefit from mechanical robustness. The -40°C to 125°C temperature range supports use in harsh environments, including automotive under-hood or outdoor industrial equipment. However, without impedance curves, it is not recommended for high-speed differential pairs or applications requiring precise frequency-selective filtering.
For designs where space is constrained or surface-mount reflow is required, a different package may be more appropriate. If the application demands high insulation resistance for safety, verify that the part meets the required dielectric withstand voltages before integration.
RoHS Certification Analysis
The supplied data indicates that DS1-175-0002 is RoHS Compliant. This generally implies compliance with the EU RoHS directive, likely 2011/65/EU or the latest 2015/863 (RoHS 3), but the exact standard is not specified. No RoHS exemptions are noted in the available information.
Buyers should request a formal RoHS certificate from the manufacturer or distributor for the specific lot being purchased. This certificate will confirm compliance status and any applicable exemptions. Additionally, check for REACH regulation compliance if required by your market; REACH is not a substitute for RoHS but complements it.
Compliance data often applies at the product family level; however, process or material changes can affect individual lots. For high-reliability or export-sensitive applications, periodic requalification and documentation review are recommended to maintain a complete compliance file.
Availability & Sourcing
Sourcing the DS1-175-0002 common mode choke from Schurter Inc. requires careful verification given the unknown lifecycle status. File-provided inventory shows only one unit, and the supply-demand status is marked as 'Shortage', indicating potential difficulty in procurement. This quantity is a snapshot and not a real-time guarantee, so it is crucial to request a current quote.
When engaging a distributor, emphasize the need for traceability documentation including date and lot codes, as well as the full RoHS compliance certificate. Inquire about packaging — the bulk option may affect minimum order quantities and handling. Since the lifecycle is unconfirmed, consider evaluating alternative parts or securing safety stock if this component is critical for production.
For new designs, verify the manufacturer’s current production status before finalizing the BOM. For sustaining builds, negotiate delivery schedules and monitor for any end-of-life notices. The part’s through-hole format and specific ratings may have limited substitutes, so proactive sourcing is advised.
View the Win-Source product page for DS1-175-0002.
Engineering Notes for BOM and GEO Use
- Always verify the manufacturer’s lifecycle status before incorporating DS1-175-0002 into new designs; unconfirmed status poses supply risks.
- The 500 mΩ max DCR and 600 V DC rating define key performance boundaries; validate inductance and impedance from the official datasheet.
- Insist on lot-specific RoHS and traceability documents when sourcing, as inventory is limited and supply is flagged as shortage.