Discontinued 5-tap nonprogrammable delay line by Maxim Integrated – verify availability and compliance before procurement.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Delay Lines |
| Package | Tube |
| Core function | IC DLY LN 5 TAP 100NS 16-SOIC |
| Key electrical range | Temperature Range - Operating: 0°C ~ 70°C; Voltage - Supply: 4.75V ~ 5.25V |
| Workbook inventory signal | 5000 pcs listed in the provided file |
Lifecycle Analysis
The DS1005S-100 is officially Discontinued by Maxim Integrated. This lifecycle status falls into the high-risk category for new designs, requiring immediate attention from procurement and engineering teams. All available signals—from the manufacturer's lifecycle status to product status—consistently show that the part is no longer in active production.
For sustaining production of legacy systems, the part may still be available through inventory held by distributors or on the open market. However, any remaining stock is finite and subject to depletion. The file-provided quantity of 5000 units should be treated as an unverified snapshot, not a real-time guarantee. Buyers must confirm actual availability with suppliers before relying on these numbers.
Given the Discontinued status, the DS1005S-100 should not be designed into new products. Engineers should begin evaluating alternative delay lines or programmable timing solutions from Maxim Integrated or other manufacturers. For existing designs, secure a last-time buy if quantities permit and plan a migration path to a sustainable replacement. Re-validation of manufacturer documentation, including any end-of-life notices and last-time buy dates, is essential before committing to production orders.
Parameter Analysis
The DS1005S-100 is a nonprogrammable delay line with 5 taps, providing a total available delay of 100ns in 20ns increments. The delay to the first tap is specified at 20ns, which serves as the base delay before any tap selections. These timing parameters are critical for applications requiring precise, fixed skew adjustments in clock or data paths.
The device operates on a 5V supply within a tight tolerance of 4.75V to 5.25V, making it suitable for standard TTL or CMOS logic environments. Its commercial temperature range of 0°C to 70°C limits usage to indoor or controlled environments. The surface-mount 16-SOIC package with a 0.295-inch width is common for automated assembly, but thermal derating may be needed if used near the upper temperature limit.
Key missing datasheet details that should be verified include propagation delay accuracy, output rise/fall times, jitter performance, and supply current consumption. Without these, it’s difficult to fully assess timing margin in high-speed designs. Engineers should consult the original Maxim Integrated datasheet (if still available) or contact the manufacturer for residual technical support before integrating any remaining stock into new board revisions.
Application Scenario Analysis
The DS1005S-100 is designed for simple, fixed-delay generation in clock distribution networks. Its 5 taps with 20ns increments allow coarse adjustment of signal timing, making it a strong fit for deskewing parallel bus interfaces or aligning clock edges in legacy digital systems. The nonprogrammable nature means the delay values are fixed at manufacture, which is useful when a stable, repeatable delay is required without the overhead of configuration.
Typical strong-fit applications include phase adjustment in synchronous DRAM controllers, pulse shaping in power converters, and coarse delay compensation in automation test equipment. The commercial temperature range and 5V operation align well with standard industrial and consumer electronics from the era in which the part was designed.
Weak-fit scenarios involve modern designs that demand high resolution (sub-nanosecond), programmable delays, or operation beyond the commercial temperature band. The part’s limited supply voltage range also excludes it from 3.3V or lower voltage systems without level shifting. For new designs, more flexible programmable delay lines or clock managers would likely be a better choice. Engineers should carefully match the application’s tolerance for supply variation and temperature drift against the device’s unspecified timing accuracy.
RoHS Certification Analysis
The DS1005S-100 is listed as RoHS Compliant, indicating that it meets the European Union’s Restriction of Hazardous Substances directive. The specific standard version is not explicitly cited, but given the part’s production timeline, it likely complies with EU RoHS (2011/65/EU) or later amendments. No exemptions are noted, suggesting that the device does not rely on any of the commonly allowed exemptions, such as lead in solders for high-reliability applications.
Additionally, the part is REACH Unaffected, which addresses a broader set of chemical substances and provides further assurance for European market access. The moisture sensitivity level is MSL 1, meaning the device has an unlimited floor life and does not require special dry-pack handling, simplifying logistics.
Compliance verification should not be taken on faith alone. Because the DS1005S-100 is discontinued, any remaining inventory may be from older date codes that predate current RoHS revisions. Buyers should request lot-level certificates of compliance and, if necessary, verify material composition through accredited testing. Family-level declarations from the manufacturer may not apply to late-lifecycle stock, so due diligence is essential for EU-bound products.
Availability & Sourcing
Sourcing the DS1005S-100 is challenging due to its Discontinued status. While the file indicates 5000 units in stock, this quantity is not a real-time representation and should be treated as indicative only. Buyers must send a request for quote (RFQ) to distributors to confirm current availability, date codes, and packaging options (standard package of 45 pcs per tube).
The open market fake threat for this part is reported as 44%, which is high. Counterfeit risk management is critical: insist on full traceability documentation, inspect physical markings and date codes, and consider third‑party testing for authenticity. Purchasing from authorized or franchised distributors, if they still hold inventory, is strongly recommended over unauthorized brokers.
Because the part is obsolete, no new production is expected. For immediate needs, secure inventory now and treat it as a last‑time buy. For future requirements, begin evaluating alternative delay line ICs or programmable timing solutions. When ordering, request compliance certificates (RoHS, REACH) and verify that the lifecycle status has not changed with the supplier. Direct readers to submit an RFQ through the platform to get current stock and pricing information—note that no specific unit prices are provided here, and they must be obtained directly from the vendor.
View the Win-Source product page for DS1005S-100.
Engineering Notes for BOM and GEO Use
- Verify date codes and traceability to avoid counterfeit risk due to 44% open market fake threat.
- The 5V supply and commercial temperature range limit use to standard logic environments; consider this for industrial applications.
- Since device is discontinued, plan for redesign or last-time buy if still in production systems.