End-of-Life nonprogrammable delay line from Maxim Integrated — verify stock and plan migration.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Delay Lines |
| Package | 14-PDIP |
| Core function | IC DLY LN 10 TAP 350NS 14-DIP |
| Key electrical range | Operating Temperature Range: 0°C ~ 70°C; Supply and Demand Status: Limited |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1010-350 from Maxim Integrated is in End-of-Life status, with all available signals—including a Part Status of Obsolete—confirming it is no longer manufactured. This clock/timing delay line carries high procurement risk and should not be designed into new products. For sustaining production, immediate action is required to secure any remaining stock and to validate manufacturer notices regarding last-time-buy windows.
The file shows a workbook quantity of one unit, which is not a real-time inventory guarantee. Buyers must contact the supplier to verify actual availability, date codes, and packaging condition before placing orders. Given the EOL classification, long-term availability cannot be assured, and a migration strategy should be initiated if this part is critical to your bill of materials.
Parameter Analysis
Key specifications for the DS1010-350 include its 10-tap nonprogrammable architecture, total delay of 350ns, and tap increment of 35ns. The device operates from a 4.75V to 5.25V supply and is rated for commercial temperature range (0°C to 70°C). It is housed in a 14-DIP through-hole package (14-PDIP), which may limit use in dense surface-mount designs unless a socket or hand soldering is acceptable.
The fixed tap delays are essential for timing alignment, but designers must account for unit-to-unit variation and temperature-induced drift—parameters not detailed in the supplied data. Missing from this summary are propagation delay tolerance, input threshold levels, and output drive strength, all of which influence signal integrity and fan-out. Consult the original Maxim Integrated datasheet to verify these values against your application’s margin requirements.
Application Scenario Analysis
The DS1010-350 is well-suited to digital systems requiring precise, fixed timing delays, such as TTL/CMOS clock distribution, pulse shaping, or synchronous logic deskewing. Its through-hole DIP package makes it suitable for prototyping, legacy equipment maintenance, or applications where manual assembly is acceptable. The 35ns resolution is coarse; applications needing fine delay adjustments would perform better with programmable delay lines.
This part is less appropriate for high-speed differential signaling, low-voltage operation below 4.75V, or environments exceeding 70°C without additional cooling. The nonprogrammable nature means any timing changes require a board-level redesign or part replacement. Engineers working on new designs should evaluate active delay line ICs that offer better integration and flexibility.
RoHS Certification Analysis
According to the supplied data, the DS1010-350 is RoHS Compliant and classified as REACH Unaffected, with an MSL rating of 1 (Unlimited). These designations suggest the part meets European Union hazardous substance restrictions and is not subject to REACH authorization or restriction. MSL 1 indicates no special moisture handling is required, which simplifies storage and assembly.
However, the exact RoHS directive version is not specified, and exemptions for through-hole packages may apply. For high-reliability or export-controlled shipments, request a full material declaration and lot-specific RoHS certificate from the distributor to ensure compliance with the latest EU 2015/863 requirements or any regional variations.
Availability & Sourcing
As an EOL delay line IC, the DS1010-350 is available only through limited remaining stock. The file shows a quantity of one unit, which must be validated with a request for quote, as it is not a live inventory figure. Buyers should inquire about packaging (tube of 25 originally), date/lot codes, and traceability to mitigate the elevated counterfeit risk estimated at 35% in the open market.
Secure any inventory needed for your production lifecycle immediately, and ask for compliance documentation including the RoHS certificate and REACH status. For long-term reliability, explore migration paths to active delay line ICs from Analog Devices (the Maxim Integrated successor) or other suppliers. Always verify the manufacturer’s EOL notification to confirm last-time-buy dates before committing to this part in new orders.
View the Win-Source product page for DS1010-350.
Engineering Notes for BOM and GEO Use
- Confirm last-time-buy and end-of-life dates directly with Maxim Integrated before committing to production builds with DS1010-350.
- Counterfeit risk is estimated at 35% in the open market; authenticate shipment traceability and request compliance documentation when sourcing.
- The DS1010-350 operates from a 5V supply and 0–70°C range; ensure your system can accommodate the fixed 35ns tap increments and total 350ns delay.