DS1021S-50 Maxim Integrated Programmable Delay Line Specs & Sourcing Guide

DS1021S-50 Maxim Integrated product image DS1021S-50 Maxim Integrated product image

EOL 256-tap programmable delay line in 16-SOIC; verification and sourcing guide for legacy 5V timing applications.

Quick Engineering Summary

FieldValue
ManufacturerMaxim Integrated
CategoryClock/Timing - Delay Lines
Package16-SOIC
Core functionIC DLY LN 256 TAP 137.
Key electrical rangeSupply and Demand Status: Limited; Supply Voltage - Operating: 4.75 V to 5.25 V; Temperature Range - Operating: 0°C to 70°C
Workbook inventory signal270 pcs listed in the provided file

Lifecycle Analysis

Maxim Integrated DS1021S-50 is confirmed End-of-Life (EOL), meaning the manufacturer has discontinued production and no new orders are being accepted. All lifecycle signals from our database align with this status, indicating that this part should not be used in new designs. For existing production lines, sustaining engineering teams must evaluate immediate replacement candidates or last-time buy opportunities to avoid line-down risk.

EOL parts carry high procurement risk due to dwindling global inventory and potential counterfeiting. The file-provided quantity of 270 units is a snapshot, not a real-time guarantee, so actual availability may be lower. Engineers should revalidate lifecycle status directly with Maxim Integrated (now Analog Devices) and secure certified stock early if this part is still required for maintenance or repair operations.

Parameter Analysis

Key parameters for the DS1021S-50 include the total delay range of 137.5ns with 256 programmable taps, yielding a fine tap increment of 500ps. The delay to first tap is 10ns, and it operates from a single 5V supply (4.75V to 5.25V) over a commercial temperature range of 0°C to 70°C. The 16-SOIC surface-mount package demands standard SMT assembly and provides a compact footprint for board-level integration.

These specifications make the part well-suited for timing alignment and clock deskew in legacy 5V TTL/CMOS systems. Engineers should verify that the maximum delay, insertion loss, and jitter meet their application requirements, as these are not fully detailed in the available data. Additionally, confirm input and output logic levels and any necessary decoupling or termination requirements directly from the original datasheet. The missing datasheet details are critical for proper integration, especially in systems sensitive to signal integrity or power sequencing.

Application Scenario Analysis

The DS1021S-50 is a strong fit for legacy digital systems requiring programmable, fine-grained propagation delay adjustment, such as data bus alignment, memory controller timing, and clock distribution in 5V microcontroller or FPGA interfaces active at 0-70°C. Its 256-step resolution supports precise calibration in test equipment, instrumentation, and industrial control loops that remain on 5V rails.

Given its obsolete status and 5V-only operation, it is a weak fit for new designs targeting low-voltage (3.3V or below), battery-powered, or high-temperature environments. The commercial temperature grade and SMD package limit use in automotive or extended industrial applications without qualification testing. Engineers should consider modern delay line ICs or FPGA-based timing solutions for new projects, reserving DS1021S-50 only for sustaining identical replacements where requalification is too costly.

RoHS Certification Analysis

The RoHS compliance status of DS1021S-50 is ambiguous. The primary compliance field indicates RoHS Compliant, but a secondary specification entry explicitly lists RoHS Non-Compliant. This conflict suggests that the part may have been originally non-compliant, with later revisions or reclassifications attempting to meet RoHS directives. Additionally, the halogen-free status is marked Not Compliant, raising further environmental compliance concerns.

Until verified, procurement teams should treat this part as possibly non-RoHS compliant, especially for shipments into the EU under RoHS 3 (EU 2015/863). Lot-level certification from the supplier is essential, and a full material declaration should be requested. Without clear exemption documentation, assume that lead-free and other restricted substance requirements are not fully guaranteed across all date/lot codes.

Availability & Sourcing

DS1021S-50 is an End-of-Life part with limited supply and a high open-market fake threat level of 51%. The file-provided inventory shows 270 units, but this is not real-time and may deplete quickly. When sourcing, demand full traceability including original manufacturer date/lot codes, packaging in tube/rail per the datasheet, and compliance documentation for RoHS and material content.

To mitigate counterfeiting risk, work only with authorized or carefully vetted distributors who can provide certificates of conformance. Request a formal quote to lock in current availability, and verify that the storage condition (dry cabinet with humidity protection) has been maintained. Given the EOL status, buyers should immediately evaluate last-time buy options and screen available stock for authenticity using visual and electrical inspection before committing to production use.

View the Win-Source product page for DS1021S-50.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance lot-by-lot; conflicting status reports demand supplier documentation for EU market access.
  • Secure certified inventory early due to EOL and 51% open-market counterfeit threat; demand full traceability.
  • DS1021S-50 is a 5V-only, commercial-temp part; do not use in new designs—migrate to modern programmable delay lines.