Active, RoHS Compliant 2.048MHz Clock Generator in 8-uMAX/uSOP package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Clock Generators, PLLs, Frequency Synthesizers |
| Package | 8-TSSOP, 8-MSOP (0.118", 3.00mm Width) |
| Core function | IC CLOCK GENERATOR 8UMAX |
| Key electrical range | Differential - Input: No/No; Frequency - Max: 2.048MHz; Input: Clock; Output: Clock |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1088LU-02A+, manufactured by Maxim Integrated, is listed as having an Active lifecycle status. This classification signals that the part is in full production and recommended for new designs. No contradictory signals appear in the supplied data, suggesting a stable supply position for the near term.
Engineers should revalidate the lifecycle status directly through Maxim Integrated’s official channel or their authorized distribution partners before finalizing a design. Active status does not guarantee indefinite availability, and manufacturers may issue end-of-life notifications with limited lead time.
The file-provided inventory quantity should be interpreted as indicative, not as a real-time stock guarantee. Procurement teams should use this information to initiate quotes but rely on live data for actual order placement.
Parameter Analysis
The DS1088LU-02A+ is a clock generator with a maximum output frequency of 2.048MHz. The device includes a divider functionality (divider/multiplier: Yes/No), meaning it can divide the input clock by a programmed ratio but cannot multiply. No PLL is integrated, so output frequency agility is limited to integer division of the input. This makes the part well-suited for low-speed clocking applications where a stable, known division ratio is required.
The operating voltage range of 2.7V to 3.6V allows use in battery-powered or low-voltage systems, with an industrial temperature range of -20°C to 85°C. Surface-mount packaging in the compact 8-uMAX/uSOP footprint (8-TSSOP, 8-MSOP variant) facilitates dense PCB layouts. However, critical parameters such as output jitter, phase noise, duty cycle accuracy, and output drive strength are not provided in the sourcing data and must be verified against the official Maxim Integrated DS1088LU datasheet.
Additionally, the programmable feature is marked as 'Not Verified'. If the application requires runtime frequency adjustment or pre-programmed values, the engineer should confirm the programming protocol and support tools, as this aspect can impact integration complexity and manufacturing flow.
Application Scenario Analysis
The DS1088LU-02A+ fits well in applications requiring a simple clock divider from a reference input, such as generating a slow bus clock from a higher-frequency processor crystal. It is suitable for consumer electronics, IoT edge devices, and low-power embedded controllers where a 2.048MHz or lower clock is needed. The lack of PLL and differential I/O makes it a straightforward, no-frills solution for integer clock division.
Weak-fit scenarios include systems requiring high-frequency clock synthesis above 2.048MHz, phase-locked loop multiplication, or low-jitter clocks for high-speed serial interfaces. The unspecified jitter performance and the absence of a PLL rule out use in precision timing or radio frequency applications. Similarly, designs needing differential clock distribution will need an alternative or external conversion circuitry.
For battery-operated sensor nodes or simple microcontroller interface clocking, the DS1088LU-02A+ provides an adequate solution, but designers should perform a worst-case timing analysis since key parameters like propagation delay and output skew are not listed in the sourcing extract.
RoHS Certification Analysis
The DS1088LU-02A+ is marked as RoHS Compliant in the supplied data, indicating conformity with European Union directives on hazardous substances. This compliance typically refers to RoHS 3 (EU 2015/863) unless otherwise specified by Maxim Integrated. However, the sourcing record does not provide a detailed certification document or lot-specific test report.
While the part-level RoHS status suggests a lead-free, hazardous-substance-free construction, compliance should be confirmed at the batch level for production runs, especially for sensitive markets like automotive or medical. The absence of REACH or halogen-free statements in the dataset means those aspects require separate verification with the manufacturer or distributor.
Procurement professionals should request the full material declaration or RoHS certificate when ordering the DS1088LU-02A+. Relying solely on a RoHS flag without supporting documentation can pose a risk during compliance audits, as component sub-assemblies may change over time.
Availability & Sourcing
Obtaining the DS1088LU-02A+ requires an RFQ workflow that prioritizes lifecycle verification, compliance documentation, and lot traceability. The component is packaged in tubes (standard for 8-uMAX/uSOP) and is currently listed with a supply-and-demand status of 'Shortage', suggesting constrained market availability. A file-provided inventory quantity exists but is not a real-time guarantee; rapid changes in stock are common for niche clock generators.
For active lifecycle parts, procurement teams should solicit quotes from multiple authorized Maxim Integrated distributors while explicitly requesting date/lot code information and RoHS certificates. This ensures that the sourced components meet both engineering and regulatory requirements. Given the shortage indication, early ordering and lead-time negotiation are prudent to mitigate supply chain disruptions.
Engineers and buyers should not rely on the file-supplied stock level for production planning. Instead, use it as a starting point for inquiry and always validate current pricing and availability through direct channels. The quote request should confirm that the delivered parts are genuine Maxim Integrated products with full traceability to avoid counterfeits, particularly when market conditions drive opportunistic sourcing.
View the Win-Source product page for DS1088LU-02A+.
Engineering Notes for BOM and GEO Use
- Confirm programming mechanism: the 'Programmable' field is Not Verified; verify DPLL or pin-strap configuration method from the official datasheet.
- Maximum frequency of 2.048MHz is a hard limit; consider this for system clock tree planning and ensure no overspecification.
- Supply-and-demand status lists Shortage; secure inventory early and request lead time and lot traceability at RFQ stage.