Maxim Integrated DS1088LU-100+: 100MHz clock generator with divider, 2.7–3.6V, 8-uMAX, RoHS compliant, active production.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Maxim Integrated |
| Category | Clock/Timing - Clock Generators, PLLs, Frequency Synthesizers |
| Package | 8-TSSOP, 8-MSOP (0.118", 3.00mm Width) |
| Core function | IC CLOCK GENERATOR 8UMAX |
| Key electrical range | Differential - Input: No/No; Frequency - Max: 100MHz; Input: Clock; Output: Clock |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DS1088LU-100+ from Maxim Integrated is listed as Active in the available lifecycle data, indicating full production status without any announced discontinuation. This means the part remains available for new designs and can be secured through authorized channels with standard lead times. Engineers should proceed with design-in confidently, but periodic checks with the manufacturer or distributor are recommended to detect any PCN that could affect future supply.
No lifecycle conflicts were found across the supplied signals; all point to an active, low-risk component. The file-provided inventory shows a limited quantity, but this is a snapshot and does not guarantee real-time availability. For production planning, always confirm current stock and lead times directly with Maxim Integrated or its authorized partners.
Parameter Analysis
The DS1088LU-100+ is a clock generator capable of delivering up to 100MHz output from a single-ended input, with a fixed 1:1 input-to-output ratio. It integrates a divider but lacks a PLL or multiplier, making it suitable for simple clock distribution tasks. The supply voltage range of 2.7V to 3.6V aligns with common 3.3V logic systems, but proper decoupling and power integrity are essential at 100MHz. The operating temperature of -20°C to 85°C covers many industrial and consumer applications, though extended-temperature designs should verify margin.
Key parameters missing from the provided data include output jitter, phase noise, rise/fall times, and the programming interface for the divider. Without these, signal integrity and timing budget assessments are incomplete. Engineers should obtain the full Maxim Integrated datasheet to evaluate these specifications before finalizing a design.
Application Scenario Analysis
The DS1088LU-100+ fits well in applications requiring simple clock division or buffering, such as generating peripheral clocks from a central oscillator in microcontrollers or FPGAs. Its 1:1 ratio and single circuit make it appropriate for point-to-point clock distribution without complex clock tree needs. The lack of a PLL or multiplier limits its use to scenarios where frequency translation is not required.
Weak-fit scenarios include high-speed serial links or systems with tight jitter requirements, where a dedicated clock cleaner or PLL-based synthesizer would be necessary. The device is not specified for automotive or extended temperature ranges, so industrial and consumer applications within -20°C to 85°C are the primary target. Verify input clock compatibility and divider programmability to ensure the output frequency matches the system's needs.
RoHS Certification Analysis
The DS1088LU-100+ is marked as RoHS Compliant, indicating that the manufacturer has taken steps to restrict hazardous substances per EU directives. The specific directive revision (e.g., RoHS 3,2015/863) is not explicitly stated in the source data, so it is prudent to request a copy of the manufacturer's Declaration of Conformity to confirm compliance with the latest requirements.
No exemptions are noted, but some applications may require verification of specific substance limits, especially if the end product is sold in the EU. Compliance is typically lot-level, so each shipment should be accompanied by appropriate certification. Additionally, REACH compliance is not mentioned; if required, obtain the relevant statements from Maxim Integrated.
Availability & Sourcing
As an active component, the DS1088LU-100+ should be available through Maxim Integrated's authorized distribution network. The file-provided inventory indicates a limited quantity, but this is not a live stock level; current availability must be confirmed via quote. For new designs, request lead times and sample availability directly from the manufacturer or franchised distributors.
When sourcing, ensure parts are supplied in original tube packaging with traceable date and lot codes to maintain quality control. Verify the lifecycle status remains active before placing production orders, and obtain RoHS documentation for each shipment. Due to the noted supply-demand status of 'Shortage,' early engagement with sourcing channels is recommended to mitigate lead time risks.
View the Win-Source product page for DS1088LU-100+.
Engineering Notes for BOM and GEO Use
- Verify the exact output frequency configuration; the divider is present but no multiplier, so output frequency depends on input clock and divider setting.
- Surface-mount 8-uMAX package requires careful PCB layout for signal integrity at 100MHz.
- Confirm RoHS certificate from Maxim Integrated to ensure compliance with the latest EU directive for your end product.